Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format

被引:41
|
作者
Miliotis, T
Kjellström, S
Nilsson, J
Laurell, T
Edholm, LE
Marko-Varga, G [1 ]
机构
[1] AstraZeneca R&D Lund, Mol Sci, SE-22187 Lund, Sweden
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Lund Inst Technol, Dept Elect Measurements, SE-22100 Lund, Sweden
关键词
D O I
10.1002/rcm.542
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm.). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 mum. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded. Copyright (C) 2001 John Wiley Sons, Ltd.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [21] Characterization of polyether mixtures using thin-layer chromatography and matrix-assisted laser desorption/ionization mass spectrometry
    Watanabe, Takehiro
    Kawasaki, Hideya
    Kimoto, Takashi
    Arakawa, Ryuichi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (05) : 787 - 791
  • [22] Biomarkers probed in saliva by surface plasmon resonance imaging coupled to matrix-assisted laser desorption/ionization mass spectrometry in array format
    Johana Musso
    William Buchmann
    Florence Gonnet
    Nathalie Jarroux
    Sophie Bellon
    Chiraz Frydman
    Didier-Luc Brunet
    Regis Daniel
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1285 - 1294
  • [23] Polymer-based metal nano-coated disposable target for matrix-assisted and matrix-free laser desorption/ionization mass spectrometry
    Bugovsky, Stefan
    Winkler, Wolfgang
    Balika, Werner
    Koranda, Manfred
    Allmaier, Guenter
    METHODS, 2016, 104 : 182 - 193
  • [24] Rapid identification of siderophores by combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry
    Hayen, H
    Volmer, DA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (05) : 711 - 720
  • [25] Thin-Layer Chromatography and Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Analysis of Oligosaccharides in Biological Samples
    Katarína Reiffová
    Jana Podolonovičová
    Lucia Onofrejová
    Jan Preisler
    Radomíra Nemcová
    JPC – Journal of Planar Chromatography – Modern TLC, 2007, 20 : 19 - 25
  • [26] Thin-layer chromatography and matrix-assisted laser desorption/ionization mass spectrometric analysis of oligosaccharides in biological samples
    Reiffova, Katarina
    Podolonovicova, Jana
    Onofrejova, Lucia
    Preisler, Jan
    Nemcova, Radomira
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2007, 20 (01) : 19 - 25
  • [27] Analysis of gangliosides directly from thin-layer chromatography plates by infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry with a glycerol matrix
    Dreisewerd, K
    Müthing, J
    Rohlfing, A
    Meisen, I
    Vukelic, Z
    Peter-Katalinic, J
    Hillenkamp, F
    Berkenkamp, S
    ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4098 - 4107
  • [28] Device for the reversed-phase separation and on-target deposition of peptides incorporating a hydrophobic sample barrier for matrix-assisted laser desorption/ionization mass spectrometry
    Chen, VC
    Cheng, K
    Ens, W
    Standing, KG
    Nagy, JI
    Perreault, H
    ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1189 - 1196
  • [29] Continuous sample deposition from reversed-phase liquid chromatography to tracks on a matrix-assisted laser desorption/ionization precoated target for the analysis of protein digests
    Wall, DB
    Berger, SJ
    Finch, JW
    Cohen, SA
    Richardson, K
    Chapman, R
    Drabble, D
    Brown, J
    Gostick, D
    ELECTROPHORESIS, 2002, 23 (18) : 3193 - 3204
  • [30] Selective Analysis of Lipids by Thin-Layer Chromatography Blot Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry
    Zaima, Nobuhiro
    Goto-Inoue, Naoko
    Adachi, Kohsuke
    Setou, Mitsutoshi
    JOURNAL OF OLEO SCIENCE, 2011, 60 (02) : 93 - 98