Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format

被引:41
|
作者
Miliotis, T
Kjellström, S
Nilsson, J
Laurell, T
Edholm, LE
Marko-Varga, G [1 ]
机构
[1] AstraZeneca R&D Lund, Mol Sci, SE-22187 Lund, Sweden
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Lund Inst Technol, Dept Elect Measurements, SE-22100 Lund, Sweden
关键词
D O I
10.1002/rcm.542
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm.). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 mum. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded. Copyright (C) 2001 John Wiley Sons, Ltd.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [1] Monolithic thin-layer chromatography plates with covalently bonded matrix for hyphenation with matrix-assisted laser desorption/ionization
    Kucherenko, Elizaveta
    Kanateva, Anastasiia
    Kurganov, Alexander
    Borisov, Roman
    Pirogov, Andrey
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (23) : 4387 - 4393
  • [2] Hydrophobin-coated plates as matrix-assisted laser desorption/ionization sample support for peptide/protein analysis
    Longobardi, Sara
    Gravagnuolo, Alfredo Maria
    Rea, Ilaria
    De Stefano, Luca
    Marino, Gennaro
    Giardina, Paola
    ANALYTICAL BIOCHEMISTRY, 2014, 449 : 9 - 16
  • [3] Coupling protocol for thin layer chromatography matrix-assisted laser desorption ionization
    Mehl, JT
    Gusev, AI
    Hercules, DM
    CHROMATOGRAPHIA, 1997, 46 (7-8) : 358 - 364
  • [4] Coupling protocol for thin layer chromatography/matrix-assisted laser desorption ionization
    J. T. Mehl
    A. I. Gusev
    D. M. Hercules
    Chromatographia, 1997, 46 : 358 - 364
  • [5] Capillary electrophoresis combined with matrix-assisted laser desorption/ionization mass spectrometry; Continuous sample deposition on a matrix-precoated membrane target
    Zhang, HY
    Caprioli, RM
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (09): : 1039 - 1046
  • [6] Three-Dimensional Printed Target Plates for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    Fialova, Jana
    Hrabak, Jaroslav
    Studentova, Vendula
    Kavan, Daniel
    Pompach, Petr
    Novak, Petr
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 12783 - 12788
  • [7] An automated noncontact deposition interface for liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry
    Ericson, C
    Phung, QT
    Horn, DM
    Peters, EC
    Fitchett, JR
    Ficarro, SB
    Salomon, AR
    Brill, LM
    Brock, A
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2309 - 2315
  • [8] Direct matrix-assisted laser desorption/ionization mass spectrometric analysis of glycosphingolipids on thin layer chromatographic plates and transfer membranes
    Guittard, J
    Hronowski, XPL
    Costello, CE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (18) : 1838 - 1849
  • [9] Direct matrix-assisted laser desorption/ionization mass spectrometric analysis of glycosphingolipids on thin layer chromatographic plates and transfer membranes
    Mass Spectrometry Resource, Depts. of Biochem. and Biophysics, Boston University School of Medicine, Boston, MA 02118-2526, United States
    不详
    不详
    Rapid Commun. Mass Spectrom., 18 (1838-1849):
  • [10] Reverse thin layer method for enhanced ion yield of oligosaccharides in matrix-assisted laser desorption/ionization
    Nishikaze, Takashi
    Amano, Junko
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (23) : 3787 - 3794