Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery

被引:60
|
作者
Otake, Y. [1 ,2 ]
Schafer, S. [1 ]
Stayman, J. W. [1 ]
Zbijewski, W. [1 ]
Kleinszig, G. [3 ]
Graumann, R. [3 ]
Khanna, A. J. [4 ]
Siewerdsen, J. H. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[3] Siemens Healthcare XP Div, Erlangen, Germany
[4] Johns Hopkins Med Inst, Dept Orthopaed Surg, Baltimore, MD 21287 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 17期
基金
美国国家卫生研究院;
关键词
CMA EVOLUTION STRATEGY; IMAGE REGISTRATION; 2D/3D REGISTRATION; 2D-3D REGISTRATION; INTRAOPERATIVE LOCALIZATION; SCREW PLACEMENT; CT; INTENSITY; ARM; RECONSTRUCTION;
D O I
10.1088/0031-9155/57/17/5485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Surgical targeting of the incorrect vertebral level (wrong-level surgery) is among the more common wrong-site surgical errors, attributed primarily to the lack of uniquely identifiable radiographic landmarks in the mid-thoracic spine. The conventional localization method involves manual counting of vertebral bodies under fluoroscopy, is prone to human error and carries additional time and dose. We propose an image registration and visualization system (referred to as LevelCheck), for decision support in spine surgery by automatically labeling vertebral levels in fluoroscopy using a GPU-accelerated, intensity-based 3D-2D (namely CT-to-fluoroscopy) registration. Agradient information (GI) similarity metric and a CMA-ES optimizer were chosen due to their robustness and inherent suitability for parallelization. Simulation studies involved ten patient CT datasets from which 50 000 simulated fluoroscopic images were generated from C-arm poses selected to approximate the C-arm operator and positioning variability. Physical experiments used an anthropomorphic chest phantom imaged under real fluoroscopy. The registration accuracy was evaluated as the mean projection distance (mPD) between the estimated and true center of vertebral levels. Trials were defined as successful if the estimated position was within the projection of the vertebral body (namely mPD <5 mm). Simulation studies showed a success rate of 99.998% (1 failure in 50 000 trials) and computation time of 4.7 s on a midrange GPU. Analysis of failure modes identified cases of false local optima in the search space arising from longitudinal periodicity in vertebral structures. Physical experiments demonstrated the robustness of the algorithm against quantum noise and x-ray scatter. The ability to automatically localize target anatomy in fluoroscopy in near-real-time could be valuable in reducing the occurrence of wrong-site surgery while helping to reduce radiation exposure. The method is applicable beyond the specific case of vertebral labeling, since any structure defined in pre-operative (or intra-operative) CT or cone-beam CT can be automatically registered to the fluoroscopic scene.
引用
收藏
页码:5485 / 5508
页数:24
相关论文
共 50 条
  • [31] Accurate and precise 2D-3D registration based on X-ray intensity
    Aouadi, Souha
    Sarry, Laurent
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (01) : 134 - 151
  • [32] A Slice Based Technique for Low-Complexity 3D/2D Registration of CT to Single Plane X-Ray Fluoroscopy
    Haque, M. N.
    Pickering, M. R.
    Biswas, M.
    Frater, M. R.
    Scarvell, J. M.
    Smith, P. N.
    2012 INTERNATIONAL CONFERENCE ON DIGITAL IMAGE COMPUTING TECHNIQUES AND APPLICATIONS (DICTA), 2012,
  • [33] 2D/3D Registration for X-ray Guided Bronchoscopy using Distance Map Classification
    Xu, Di
    Xu, Sheng
    Herzka, Daniel A.
    Yung, Rex C.
    Bergtholdt, Martin
    Gutierrez, Luis F.
    McVeigh, Elliot R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3715 - 3718
  • [34] A study for non-rigid 2x2D-3D registration of coronary artery images using bifurcation points matching with bi-plane x-ray fluoroscopy
    Yoon, Siyeop
    Son, Jinwon
    Kim, Youngjun
    Park, Sehyung
    Lee, Deukhee
    2017 14TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2017, : 583 - 584
  • [35] Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration
    Uneri, A.
    De Silva, T.
    Goerres, J.
    Jacobson, M. W.
    Ketcha, M. D.
    Reaungamornrat, S.
    Kleinszig, G.
    Vogt, S.
    Khanna, A. J.
    Osgood, G. M.
    Wolinsky, J-P
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08): : 3330 - 3351
  • [36] Registration of 3D trans-esophageal echocardiography to X-ray fluoroscopy using image-based probe tracking
    Gao, Gang
    Penney, Graeme
    Ma, Yingliang
    Gogin, Nicolas
    Cathier, Pascal
    Arujuna, Aruna
    Morton, Geraint
    Caulfield, Dennis
    Gill, Jaswinder
    Rinaldi, C. Aldo
    Hancock, Jane
    Redwood, Simon
    Thomas, Martyn
    Razavi, Reza
    Gijsbers, Geert
    Rhode, Kawal
    MEDICAL IMAGE ANALYSIS, 2012, 16 (01) : 38 - 49
  • [37] 3D/2D image registration: The impact of X-ray views and their number
    Tomazevic, Dejan
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 450 - +
  • [38] 3D kinematics of normal knee using X-ray fluoroscopy and CT images
    Yamazaki, T.
    Watanabe, T.
    Tomita, T.
    Sugamoto, K.
    Ogasawara, M.
    Sato, Y.
    Yoshikawa, H.
    Tamura, S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2793 - +
  • [39] Robust Intensity-based 3D-2D Registration of CT and X-ray Images for Precise Estimation of Cup Alignment after Total Hip Arthroplasty
    Zheng, Guoyan
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 2145 - 2148
  • [40] Operating Room Quality Assurance (ORQA) for Spine Surgery Using Known-Component 3D-2D Image Registration
    Uneri, A.
    De Silva, T.
    Goerres, J.
    Jacobson, M.
    Ketcha, M.
    Reaungamornrat, S.
    Kleinszig, G.
    Vogt, S.
    Khanna, A.
    Wolinsky, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3792 - 3792