X-ray diagnostic calibration with the tabletop laser facility EQUINOX

被引:13
|
作者
Reverdin, Charles [1 ]
Paurisse, M. [1 ]
Caillaud, T. [1 ]
Combis, P. [1 ]
Duval, A. [1 ]
Gontier, D. [1 ]
Husson, D. [1 ]
Rubbelynck, C. [1 ]
Zuber, C. [1 ]
机构
[1] CEA DIF, F-91297 Arpajon, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
calibration; CCD image sensors; X-ray detection; X-ray spectrometers;
D O I
10.1063/1.2965212
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The broadband x-ray emission of a target irradiated by a laser can be used to check the calibration of detectors. At CEA-DIF we have a tabletop picosecond laser facility called EQUINOX with 0.3 J at 800 nm. The laser is focused inside a target chamber onto a solid target and produces bright radiation in the 100-2000 eV spectral range. The x-ray source is routinely monitored with a pinhole camera for source dimension measurement and with x-ray diodes for flux measurement. In addition an x-ray transmission grating spectrometer, a crystal spectrometer, and a single count charge coupled device camera measure the x-ray spectrum between 100 eV and 15 keV. The absolute calibration of those sets of spectrometers allows us to fully characterize x-ray emission spectra. Typical duration is less than 100 ps. The spectrum can be tuned by changing target material, pulse length, and x-ray filters. An application to checking the calibration of x-ray diodes used in the broad band spectrometer DMX with single shots will be presented.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A SET OF X-RAY FILTERS FOR A DOSEMETER CALIBRATION FACILITY
    BURT, AK
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (01): : 131 - &
  • [22] ROUTINE CALIBRATION OF DIAGNOSTIC X-RAY MACHINES
    BULL, SM
    BURLIN, TE
    BRITISH JOURNAL OF RADIOLOGY, 1962, 35 (419): : 796 - 797
  • [23] Formation of sub-μm x-ray beam from tabletop soft x-ray laser
    Ohchi, T
    Yamaguchi, N
    Fujikawa, C
    Hara, T
    X-RAY LASERS 1998, 1999, 159 : 683 - 686
  • [24] X-ray laser facility at the PALS centre
    Rus, B
    Mocek, T
    Präg, AR
    Lagron, JC
    Hudecek, M
    Jamelot, G
    Rohlena, K
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR2): : 589 - 596
  • [25] X-ray facility for the ground calibration of the X-ray monitor JEM-X on board INTEGRAL
    Loffredo, G
    Pelliciari, C
    Frontera, F
    Carassiti, V
    Chiozzi, S
    Evangelisti, F
    Landi, L
    Melchiorri, M
    Squerzanti, S
    Brandt, S
    Budtz-Joergensen, C
    Laursen, S
    Lund, N
    Polny, J
    Westergaard, NJ
    ASTRONOMY & ASTROPHYSICS, 2003, 411 (01) : L239 - L242
  • [26] X-ray measurements of a prototype WFXT SiC mirror at the MSFC X-ray Calibration Facility
    Ghigo, M
    Citterio, O
    Mazzoleni, F
    Kolodziejczak, JJ
    O'Dell, SL
    Austin, RA
    Zirnstein, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 : 207 - 220
  • [27] VERT-X: a new calibration facility for X-ray optics
    Moretti, A.
    Pareschi, G.
    Basso, S.
    Spiga, D.
    Ghigo, M.
    Sironi, G.
    Tagliaferri, G.
    Civitani, M.
    Cotroneo, V.
    La Palombara, N.
    Uslenghi, M.
    Tordi, M.
    de Lorenzi, S.
    Dury, F.
    Valsecchi, G.
    Zocchi, F.
    Marioni, F.
    Vernani, D.
    Amisano, F.
    Parissenti, G.
    Parodi, G.
    Ottolini, M.
    Corradi, P.
    Bavdaz, M.
    Ferreira, I.
    Proceedings of SPIE - The International Society for Optical Engineering, 2023, 12777
  • [28] Proposed tabletop laser-driven coherent X-ray source
    Plettner, T.
    Byer, R. L.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 3531 - 3533
  • [29] Demonstration of a high average power tabletop soft X-ray laser
    Benware, BR
    Macchietto, CD
    Moreno, CH
    Rocca, JJ
    PHYSICAL REVIEW LETTERS, 1998, 81 (26) : 5804 - 5807
  • [30] X-RAY LASER PLASMA SOURCE FOR CALIBRATION
    BENATTAR, R
    MALKA, V
    SEZEN, A
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 238 - 246