In-situ measurement of oxygen concentration under high pressure and the application to oxygen permeation through polymer films

被引:2
|
作者
Sterr, Julia [1 ]
Roetzer, Katharina [1 ]
Weck, Kathrin [1 ]
Wirth, Andreas Leonhard Karl [1 ]
Fleckenstein, Benedikt Stefan [1 ]
Langowski, Horst-Christian [1 ,2 ]
机构
[1] Tech Univ Munich, Ctr Life & Food Sci Weihenstephan, Freising Weihenstephan, Germany
[2] Fraunhofer Inst Proc Engn & Packaging, Freising Weihenstephan, Germany
来源
JOURNAL OF CHEMICAL PHYSICS | 2015年 / 143卷 / 11期
关键词
FLUORESCENCE; COMPLEXES; SORPTION; SYSTEMS;
D O I
10.1063/1.4931399
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Up until now, gas permeation through polymers under high pressure has not been able to be measured continuously. The combination of a special high pressure cell and a commercially available fluorescence-based oxygen measurement system allows in-situ monitoring of oxygen permeation through a polymer sample under pressure in an aqueous environment. The principle of the oxygen sensor is based on dynamic fluorescence quenching and measurement of the fluorescence decay time. It was observed that the decay time increases non-linearly with the applied pressure, and hence, the displayed oxygen concentration has to be corrected. This deviation between the measured and the real concentration depends not only on the pressure but also on the absolute oxygen concentration in the water. To obtain a calibration curve, tests were performed in the pressure range between 1 and 2000 bars and initial oxygen concentrations in the range between 40 and 280 mu mol/l. The polynomial calibration curve was of the fourth order, describing the raw data with a coefficient of determination R-2 > 0.99. The effective oxygen permeation through polymeric samples can be calculated with this function. A pressure hysteresis test was undertaken but no hysteresis was found. No temperature dependence of the oxygen sensor signal was observed in the range between 20 degrees C and 30 degrees C. This study presents for the first time data showing the oxygen permeation rates through a polyethylene film in the pressure range between 1 and 2000 bars at 23 degrees C. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [32] In-situ control of oxygen fugacity in water-free systems at high temperature and high pressure
    Li, HP
    Xie, HS
    Guo, J
    Zhang, YM
    Xu, ZM
    Xu, JA
    CHINESE PHYSICS LETTERS, 1998, 15 (03): : 162 - 164
  • [33] In-situ conductivity measurement of BaF2 under high pressure and high temperature
    Hao, Ai-Min
    Gao, Chun-Xiao
    Ming, Li
    He, Chun-Yuan
    Huang, Xiao-Wei
    Zhang, Dong-Mei
    Yu, Cui-Ling
    Tian, Zou Guang
    Li, Yan-Chun
    Li, Xiao-Dong
    Jing, Liu
    CHINESE PHYSICS LETTERS, 2006, 23 (11) : 2917 - 2919
  • [34] TITANIUM NITRIDE FILMS WITH HIGH OXYGEN CONCENTRATION
    ANG, SS
    JOURNAL OF ELECTRONIC MATERIALS, 1988, 17 (02) : 95 - 100
  • [35] In-situ growth monitoring during PLD of oxides using RHEED at high oxygen pressure
    Rijnders, GJHM
    Koster, G
    Blank, DHA
    Rogalla, H
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1998, 56 (2-3): : 223 - 227
  • [36] In-situ monitoring during PLD of complex oxides using RHEED at high oxygen pressure
    Rijnders, GJHM
    Koster, G
    Blank, DHA
    Rogalla, H
    IN SITU PROCESS DIAGNOSTICS AND INTELLIGENT MATERIALS PROCESSING, 1998, 502 : 209 - 213
  • [37] In-situ resistivity measurement of ZnS in diamond anvil cell under high pressure
    Han, YH
    Luo, JF
    Hao, AM
    Gao, CX
    Xie, HS
    Qu, SC
    Liu, HW
    Zou, GT
    CHINESE PHYSICS LETTERS, 2005, 22 (04) : 927 - 930
  • [38] PERMEATION OF OXYGEN THROUGH POLYURETHANE-POLYEPOXIDE INTERPENETRATING POLYMER NETWORKS
    CHEN, SA
    JU, HL
    JOURNAL OF APPLIED POLYMER SCIENCE, 1980, 25 (06) : 1105 - 1116
  • [39] In-Situ EPR Measurement of Reactive Oxygen Species in Cultured Cells
    Ando, Takahiro
    Yonamoto, Yoshiki
    FREE RADICAL BIOLOGY AND MEDICINE, 2014, 76 : S145 - S145
  • [40] Investigation on the Instability of Methane/Oxygen Combustion Under High Oxygen Concentration
    Zhao, Xiao-Yao
    Shi, Bao-Lu
    Li, Bo
    Ma, Kang
    Yu, Xiao
    Wang, Ning-Fei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (02): : 474 - 481