In-situ measurement of oxygen concentration under high pressure and the application to oxygen permeation through polymer films

被引:2
|
作者
Sterr, Julia [1 ]
Roetzer, Katharina [1 ]
Weck, Kathrin [1 ]
Wirth, Andreas Leonhard Karl [1 ]
Fleckenstein, Benedikt Stefan [1 ]
Langowski, Horst-Christian [1 ,2 ]
机构
[1] Tech Univ Munich, Ctr Life & Food Sci Weihenstephan, Freising Weihenstephan, Germany
[2] Fraunhofer Inst Proc Engn & Packaging, Freising Weihenstephan, Germany
来源
JOURNAL OF CHEMICAL PHYSICS | 2015年 / 143卷 / 11期
关键词
FLUORESCENCE; COMPLEXES; SORPTION; SYSTEMS;
D O I
10.1063/1.4931399
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Up until now, gas permeation through polymers under high pressure has not been able to be measured continuously. The combination of a special high pressure cell and a commercially available fluorescence-based oxygen measurement system allows in-situ monitoring of oxygen permeation through a polymer sample under pressure in an aqueous environment. The principle of the oxygen sensor is based on dynamic fluorescence quenching and measurement of the fluorescence decay time. It was observed that the decay time increases non-linearly with the applied pressure, and hence, the displayed oxygen concentration has to be corrected. This deviation between the measured and the real concentration depends not only on the pressure but also on the absolute oxygen concentration in the water. To obtain a calibration curve, tests were performed in the pressure range between 1 and 2000 bars and initial oxygen concentrations in the range between 40 and 280 mu mol/l. The polynomial calibration curve was of the fourth order, describing the raw data with a coefficient of determination R-2 > 0.99. The effective oxygen permeation through polymeric samples can be calculated with this function. A pressure hysteresis test was undertaken but no hysteresis was found. No temperature dependence of the oxygen sensor signal was observed in the range between 20 degrees C and 30 degrees C. This study presents for the first time data showing the oxygen permeation rates through a polyethylene film in the pressure range between 1 and 2000 bars at 23 degrees C. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] IN-SITU MEASUREMENT OF PHOTOSYNTHETIC OXYGEN PRODUCTION IN THE WATER COLUMN
    HADER, DP
    SCHAFER, J
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1994, 32 (03) : 259 - 268
  • [22] In-situ pH measurement of selected liquid foods under high pressure
    Samaranayake, Chaminda P.
    Sastry, Sudhir K.
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2013, 17 : 22 - 26
  • [23] In-situ Impedance Spectroscopy Measurement of CdS Nanocrystals under High Pressure
    杨洁
    任万斌
    李岩
    吴宝嘉
    延边大学学报(自然科学版), 2010, (04) : 309 - 312
  • [24] High temperature in-situ combustion oxygen sensors
    Knight, B.
    Boltz, E.S.
    Ammonia Plant Safety and Related Facilities, 2001, 41 : 186 - 191
  • [25] Mechanisms of oxygen permeation through plastic films and barrier coatings
    Wilski, Stefan
    Wipperfrth, Jens
    Jaritz, Montgomery
    Kirchheim, Dennis
    Mitschker, Felix
    Awakowicz, Peter
    Dahlmann, Rainer
    Hopmann, Christian
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (42)
  • [26] In-situ laser measurement of oxygen concentration and flue gas temperature utilizing chemical reaction kinetics
    Viljanen, Jan
    Sorvajarvi, Tapio
    Toivonen, Juha
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [27] Permeation of oxygen and nitrogen gases through novel polyurethane films
    Tsuchida, Toshio
    Arimatsu, Yoshikazu
    Yoda, Kentaro
    Polymer communications Guildford, 1988, 29 (08): : 246 - 248
  • [28] In Situ Measurement of Oxygen Permeability in Polymer Electrolyte Membranes
    Sambandam, S.
    Ramani, V.
    PROTON EXCHANGE MEMBRANE FUEL CELLS 9, 2009, 25 (01): : 433 - 441
  • [29] PERMEATION OF OXYGEN AND NITROGEN GASES THROUGH NOVEL POLYURETHANE FILMS
    TSUCHIDA, T
    ARIMATSU, Y
    YODA, K
    POLYMER COMMUNICATIONS, 1988, 29 (08): : 246 - 248
  • [30] OXYGEN PERMEATION THROUGH FILMS OF POLYPROPYLENE HYDROGENATED OLIGOCYCLOPENTADIENE BLENDS
    MARCANDALLI, B
    TESTA, G
    SEVES, A
    MARTUSCELLI, E
    POLYMER, 1991, 32 (18) : 3376 - 3380