In-situ measurement of oxygen concentration under high pressure and the application to oxygen permeation through polymer films

被引:2
|
作者
Sterr, Julia [1 ]
Roetzer, Katharina [1 ]
Weck, Kathrin [1 ]
Wirth, Andreas Leonhard Karl [1 ]
Fleckenstein, Benedikt Stefan [1 ]
Langowski, Horst-Christian [1 ,2 ]
机构
[1] Tech Univ Munich, Ctr Life & Food Sci Weihenstephan, Freising Weihenstephan, Germany
[2] Fraunhofer Inst Proc Engn & Packaging, Freising Weihenstephan, Germany
来源
JOURNAL OF CHEMICAL PHYSICS | 2015年 / 143卷 / 11期
关键词
FLUORESCENCE; COMPLEXES; SORPTION; SYSTEMS;
D O I
10.1063/1.4931399
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Up until now, gas permeation through polymers under high pressure has not been able to be measured continuously. The combination of a special high pressure cell and a commercially available fluorescence-based oxygen measurement system allows in-situ monitoring of oxygen permeation through a polymer sample under pressure in an aqueous environment. The principle of the oxygen sensor is based on dynamic fluorescence quenching and measurement of the fluorescence decay time. It was observed that the decay time increases non-linearly with the applied pressure, and hence, the displayed oxygen concentration has to be corrected. This deviation between the measured and the real concentration depends not only on the pressure but also on the absolute oxygen concentration in the water. To obtain a calibration curve, tests were performed in the pressure range between 1 and 2000 bars and initial oxygen concentrations in the range between 40 and 280 mu mol/l. The polynomial calibration curve was of the fourth order, describing the raw data with a coefficient of determination R-2 > 0.99. The effective oxygen permeation through polymeric samples can be calculated with this function. A pressure hysteresis test was undertaken but no hysteresis was found. No temperature dependence of the oxygen sensor signal was observed in the range between 20 degrees C and 30 degrees C. This study presents for the first time data showing the oxygen permeation rates through a polyethylene film in the pressure range between 1 and 2000 bars at 23 degrees C. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] SINGLET OXYGEN - INTERMEDIATE IN THE INHIBITION OF OXYGEN PERMEATION THROUGH POLYMER-FILMS
    ROONEY, ML
    HOLLAND, RV
    CHEMISTRY & INDUSTRY, 1979, (24) : 900 - 901
  • [2] Electrochemical Measurement of the Oxygen Permeation Rate through Polymer Electrolyte Membranes
    Zhang, Jingxin
    Gasteiger, Hubert A.
    Gu, Wenbin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (06) : F616 - F622
  • [3] In-Situ Measurement of Oxygen Partial Pressure in a Cathode Catalyst Layer
    Epting, W. K.
    Hess, K. C.
    Litster, S.
    POLYMER ELECTROLYTE FUEL CELLS 10, PTS 1 AND 2, 2010, 33 (01): : 1241 - 1249
  • [4] Luminescence measurements of oxygen permeation and oxygen diffusion in thin polymer films
    Yekta, Ahmad
    Masoumi, Zahra
    Winnik, Mitchell A.
    Canadian Journal of Chemistry, 1995, 73 (11): : 2021 - 2029
  • [5] Luminescence measurements of oxygen permeation and oxygen diffusion in thin polymer films
    Yekta, A
    Masoumi, Z
    Winnik, MA
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1995, 73 (11): : 2021 - 2029
  • [6] Permeation of a Range of Species through Polymer Layers under Varying Conditions of Temperature and Pressure: In Situ Measurement Methods
    Craster, Bernadette
    Jones, Timothy G. J.
    POLYMERS, 2019, 11 (06)
  • [7] Electrical resistance measurement of oxygen under high pressure
    Shimizu, K
    Suhara, K
    Amaya, K
    Endo, S
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1996, 65 (06) : 1527 - 1528
  • [8] PERMEATION OF OXYGEN, ARGON AND NITROGEN THROUGH POLYMER MEMBRANES
    HARAYA, K
    HWANG, ST
    JOURNAL OF MEMBRANE SCIENCE, 1992, 71 (1-2) : 13 - 27
  • [9] IN-SITU MEASUREMENT OF DISSOLVED NITROGEN AND OXYGEN IN THE OCEAN
    MCNEIL, CL
    JOHNSON, BD
    FARMER, DM
    DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 1995, 42 (05) : 819 - 826
  • [10] In-situ Measurement of Oxygen Partial Pressure in the Cathode Flow Field with a Hydrophilic Surface
    Hirano, S.
    Potocki, M. R.
    Saloka, G. S.
    Palluconi, S. J.
    Crafton, J. W.
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 1791 - 1797