Novel reference radiation fields for pulsed photon radiation installed at PTB

被引:21
|
作者
Klammer, J. [1 ]
Roth, J. [1 ]
Hupe, O. [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1093/rpd/ncs043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, approximate to 70 of the occupationally exposed persons in Germany are working in pulsed radiation fields, mainly in the medical sector. It has been known for a few years that active electronic dosemeters exhibit considerable deficits or can even fail completely in pulsed fields. Type test requirements for dosemeters exist only for continuous radiation. Owing to the need of a reference field for pulsed photon radiation and accordingly to the upcoming type test requirements for dosemeters in pulsed radiation, the Physikalisch-Technische Bundesanstalt has developed a novel X-ray reference field for pulsed photon radiation in cooperation with a manufacturer. This reference field, geared to the main applications in the field of medicine, has been well characterised and is now available for research and type testing of dosemeters in pulsed photon radiation.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [41] A vacuum infrared standard radiation thermometer at the PTB
    Gutschwager, B.
    Hollandt, J.
    Jankowski, T.
    Gaertner, R.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (01) : 330 - 340
  • [42] A Vacuum Infrared Standard Radiation Thermometer at the PTB
    B. Gutschwager
    J. Hollandt
    T. Jankowski
    R. Gärtner
    International Journal of Thermophysics, 2008, 29 : 330 - 340
  • [43] Establishment and Study of Pulsed X-ray Reference Radiation Field
    Gao F.
    Wang F.
    Liu Y.
    Ding Y.
    Chen Y.
    Ni N.
    Wang Z.
    Liu J.
    Wang Z.
    Zhao X.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2023, 57 (02): : 389 - 397
  • [44] On the use of a recombination chamber for radiation measurements in CERN-EU high energy reference radiation fields
    Golnik, N
    Silari, M
    Otto, T
    RADIATION PROTECTION DOSIMETRY, 1999, 86 (03) : 175 - 179
  • [45] Time-resolved spectrometry for the characterization of a reference field for pulsed radiation
    Sievers, P.
    Klammer, J.
    Hupe, O.
    Michel, T.
    Anton, G.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [46] Origins of the changing detector response in small megavoltage photon radiation fields
    Fenwick, John D.
    Georgiou, Georgios
    Rowbottom, Carl G.
    Underwood, Tracy S. A.
    Kumar, Sudhir
    Nahum, Alan E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12):
  • [47] Status and prospects of electronic personal dosemeters for neutron/photon radiation fields
    Luszik-Bhadra, M.
    Rimpler, A.
    Wahl, W.
    KERNTECHNIK, 2022, 68 (04) : 135 - 139
  • [48] Status and prospects of electronic personal dosemeters for neutron/photon radiation fields
    Luszik-Bhadra, M
    Rimpler, A
    Wahl, W
    KERNTECHNIK, 2003, 68 (04) : 135 - 139
  • [49] Photon-excited carriers and emission of graphene in terahertz radiation fields
    Tao Ze-Hua
    Dong Hai-Ming
    Duan Yi-Feng
    ACTA PHYSICA SINICA, 2018, 67 (02)
  • [50] Pulsed radiation-induced conductivity of polymers in strong electric fields
    Tyutnev, A. P.
    Linetskii, B. L.
    Nikerov, A. V.
    Saenko, V. S.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B, 2015, 9 (04) : 648 - 651