Novel reference radiation fields for pulsed photon radiation installed at PTB

被引:21
|
作者
Klammer, J. [1 ]
Roth, J. [1 ]
Hupe, O. [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1093/rpd/ncs043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, approximate to 70 of the occupationally exposed persons in Germany are working in pulsed radiation fields, mainly in the medical sector. It has been known for a few years that active electronic dosemeters exhibit considerable deficits or can even fail completely in pulsed fields. Type test requirements for dosemeters exist only for continuous radiation. Owing to the need of a reference field for pulsed photon radiation and accordingly to the upcoming type test requirements for dosemeters in pulsed radiation, the Physikalisch-Technische Bundesanstalt has developed a novel X-ray reference field for pulsed photon radiation in cooperation with a manufacturer. This reference field, geared to the main applications in the field of medicine, has been well characterised and is now available for research and type testing of dosemeters in pulsed photon radiation.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [31] A TECHNOLOGY OVERVIEW OF ACTIVE IONIZING RADIATION DOSEMETERS FOR PHOTON FIELDS
    Pavelic, Luka
    Lackovic, Igor
    Mihic, Marija Suric
    Prlic, Ivica
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) : 361 - 371
  • [32] Personal Dosimetry in Continuous Photon Radiation Fields With the Dosepix Detector
    Haag, Dennis
    Schmidt, Sebastian
    Hufschmidt, Patrick
    Eberle, Franziska
    Michel, Thilo
    Anton, Gisela
    Hupe, Oliver
    Roth, Juergen
    Fuhg, Christian
    Zutz, Hayo
    Behrens, Rolf
    Campbell, Michael
    Llopart, Xavier
    Ballabriga, Rafael
    Tlustos, Lukas
    Wong, Winnie
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (05) : 1129 - 1134
  • [33] Semiconductor microdosimetry in mixed radiation and photon fields: Present and future
    Rosenfeld, AB
    Bradley, PD
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 385 - 388
  • [34] Deficiencies of active electronic radiation protection dosemeters in pulsed fields
    Ankerhold, U.
    Hupe, O.
    Ambrosi, P.
    RADIATION PROTECTION DOSIMETRY, 2009, 135 (03) : 149 - 153
  • [35] MICRODOSIMETRY OF PULSED RADIATION-FIELDS EMPLOYING THE VARIANCE METHOD
    KLIAUGA, P
    AMOLS, H
    LINDBORG, L
    RADIATION RESEARCH, 1986, 105 (02) : 129 - 137
  • [36] RADIATION PATTERNS AND RADIATION FIELDS
    MULLER, C
    JOURNAL OF RATIONAL MECHANICS AND ANALYSIS, 1955, 4 (02): : 235 - 246
  • [38] Dose build up correction for radiation monitors in high-energy bremsstrahlung photon radiation fields
    Nair, Haridas G.
    Nayak, M. K.
    Dev, Vipin
    Thakkar, K. K.
    Sarkar, P. K.
    Sharma, D. N.
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (03) : 233 - 237
  • [39] Installed Radiation Pattern of Patch Antennas
    Gao, Si-Ping
    Wang, Binfang
    Zhao, Huapeng
    Zhao, Wei-Jiang
    Png, Ching Eng
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2015, 57 (03) : 81 - 94
  • [40] Correction factors for two new reference beta radiation fields
    Behrens, R.
    METROLOGIA, 2020, 57 (06)