Closed-Loop Control of Functional Electrical Stimulation-Assisted Arm-Free Standing in Individuals With Spinal Cord Injury: A Feasibility Study

被引:32
|
作者
Vette, Albert H. [1 ,2 ]
Masani, Kei [2 ]
Kim, Joon-Young [2 ,3 ]
Popovic, Milos R. [2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Rehabil Engn Lab, Toronto, ON M5S 3G9, Canada
[2] Lyndhurst Ctr, Toronto Rehabil Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G9, Canada
来源
NEUROMODULATION | 2009年 / 12卷 / 01期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Arm-free standing; functional electrical stimulation; multibody dynamics; neuroprosthesis; proportional and derivative controller; sensory-motor time delay; spinal cord injury; INVERTED PENDULUM; QUIET; DESIGN; TORQUE;
D O I
10.1111/j.1525-1403.2009.00184.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The purpose of the present study was to show that the design of a neuroprosthesis for unsupported (arm-free) standing is feasible. We review findings suggesting that a closed-loop controlled functional electrical stimulation (FES) system should be able to facilitate arm-free quiet standing in individuals with spinal cord injury (SCI). Particularly, this manuscript identifies: 1) a control strategy that accurately mimics the strategy healthy individuals apply to regulate the ankle joint position during quiet standing and 2) the degrees of freedom (DOF) of the redundant, closed-chain dynamic system of bipedal stance that have to be regulated to facilitate stable standing. First, we utilized a single DOF model of quiet standing (inverted pendulum) to analytically identify a proportional and derivative (PD) feedback controller that regulates the ankle torque in a physiologic manner despite a long sensory-motor time delay. Second, these theoretic results were experimentally validated by implementing the proposed PD controller to stabilize an individual with SCI during quiet standing. Third, a realistic, three-dimensional dynamic model of quiet standing with 12 DOF was used to determine the optimal combination of the minimum number of DOF that need to be regulated with the PD controller to ensure stability during quiet standing. Finally, perturbation simulations confirmed that the kinematics of this system are similar to those of healthy individuals during perturbed standing. The presented results suggest that stable standing can be achieved in individuals with SCI by controlling only six DOF in the lower limbs using FES, and that a PD controller actuating these DOF can stabilize the system despite a long sensory-motor time delay. Our finding that not all DOF in the lower limbs need to be regulated is particularly relevant for individuals with complete SCI, because some of their muscles may be denervated or difficult to access.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [41] Closed-Loop Control of Functional Electrical Stimulation Using a Selectively Recording and Bidirectional Nerve Cuff Interface
    Hwang, Yi-Chin E.
    Long, Liam
    Filho, Jose Sales
    Genov, Roman
    Zariffa, Jose
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 504 - 513
  • [42] Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation
    Haugland, Morten K.
    Hoffer, J.Andy
    IEEE Transactions on Rehabilitation Engineering, 1994, 2 (01): : 29 - 36
  • [43] Ultrasound Imaging-Based Closed-Loop Control of Functional Electrical Stimulation for Drop Foot Correction
    Zhang, Qiang
    Lambeth, Krysten
    Iyer, Ashwin
    Sun, Ziyue
    Sharma, Nitin
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2023, 31 (03) : 989 - 1005
  • [44] Closed-Loop, Cervical, Epidural Stimulation Elicits Respiratory Neuroplasticity after Spinal Cord Injury in Freely Behaving Rats
    Malone, Ian G.
    Kelly, Mia N.
    Nosacka, Rachel L.
    Nash, Marissa A.
    Yue, Sijia
    Xue, Wei
    Otto, Kevin J.
    Dale, Erica A.
    ENEURO, 2022, 9 (01)
  • [45] Cardiovascular Response of Individuals With Spinal Cord Injury to Dynamic Functional Electrical Stimulation Under Orthostatic Stress
    Yoshida, Takashi
    Masani, Kei
    Sayenko, Dimitry G.
    Miyatani, Masae
    Fisher, Joseph A.
    Popovic, Milos R.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (01) : 37 - 46
  • [46] The Effects of Functional Electrical Stimulation Cycling on Muscle Spasticity in Individuals With Spinal Cord Injury: A Systematic Review
    Couper, Stephanie K.
    Smith, Moira
    TOPICS IN SPINAL CORD INJURY REHABILITATION, 2025, 31 (01) : 77 - 99
  • [47] Functional electrical stimulation cycling in patients with chronic spinal cord injury: a pilot study
    Gurcay, Eda
    Karaahmet, Ozgur Zeliha
    Cankurtaran, Damla
    Nazli, Fatma
    Umay, Ebru
    Guzel, Sukran
    Gurcay, Ahmet Gurhan
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2022, 132 (04) : 421 - 427
  • [48] Stimulation of Shank Muscles During Functional Electrical Stimulation Cycling Increases Ankle Excursion in Individuals With Spinal Cord Injury
    Fornusek, Che
    Davis, Glen M.
    Baek, Ilhun
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 1930 - 1936
  • [49] Functional Ultrasound Imaging of Spinal Cord Hemodynamic Responses to Epidural Electrical Stimulation: A Feasibility Study
    Song, Pengfei
    Cuellar, Carlos A.
    Tang, Shanshan
    Islam, Riazul
    Wen, Hai
    Huang, Chengwu
    Manduca, Armando
    Trzasko, Joshua D.
    Knudsen, Bruce E.
    Lee, Kendall H.
    Chen, Shigao
    Lavrov, Igor A.
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [50] Development of a closed-loop controller for functional electrical stimulation therapy plus visual feedback balance training for standing balance training
    Lee, Jae W.
    Grabke, Emerson
    Chow, Kelvin
    Musselman, Kristin E.
    Masani, Kei
    MEDICAL ENGINEERING & PHYSICS, 2024, 132