Closed-Loop Control of Functional Electrical Stimulation-Assisted Arm-Free Standing in Individuals With Spinal Cord Injury: A Feasibility Study

被引:32
|
作者
Vette, Albert H. [1 ,2 ]
Masani, Kei [2 ]
Kim, Joon-Young [2 ,3 ]
Popovic, Milos R. [2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Rehabil Engn Lab, Toronto, ON M5S 3G9, Canada
[2] Lyndhurst Ctr, Toronto Rehabil Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G9, Canada
来源
NEUROMODULATION | 2009年 / 12卷 / 01期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Arm-free standing; functional electrical stimulation; multibody dynamics; neuroprosthesis; proportional and derivative controller; sensory-motor time delay; spinal cord injury; INVERTED PENDULUM; QUIET; DESIGN; TORQUE;
D O I
10.1111/j.1525-1403.2009.00184.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The purpose of the present study was to show that the design of a neuroprosthesis for unsupported (arm-free) standing is feasible. We review findings suggesting that a closed-loop controlled functional electrical stimulation (FES) system should be able to facilitate arm-free quiet standing in individuals with spinal cord injury (SCI). Particularly, this manuscript identifies: 1) a control strategy that accurately mimics the strategy healthy individuals apply to regulate the ankle joint position during quiet standing and 2) the degrees of freedom (DOF) of the redundant, closed-chain dynamic system of bipedal stance that have to be regulated to facilitate stable standing. First, we utilized a single DOF model of quiet standing (inverted pendulum) to analytically identify a proportional and derivative (PD) feedback controller that regulates the ankle torque in a physiologic manner despite a long sensory-motor time delay. Second, these theoretic results were experimentally validated by implementing the proposed PD controller to stabilize an individual with SCI during quiet standing. Third, a realistic, three-dimensional dynamic model of quiet standing with 12 DOF was used to determine the optimal combination of the minimum number of DOF that need to be regulated with the PD controller to ensure stability during quiet standing. Finally, perturbation simulations confirmed that the kinematics of this system are similar to those of healthy individuals during perturbed standing. The presented results suggest that stable standing can be achieved in individuals with SCI by controlling only six DOF in the lower limbs using FES, and that a PD controller actuating these DOF can stabilize the system despite a long sensory-motor time delay. Our finding that not all DOF in the lower limbs need to be regulated is particularly relevant for individuals with complete SCI, because some of their muscles may be denervated or difficult to access.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [31] Paraplegia: Prolonged standing using closed-loop functional electrical stimulation and Andrews ankle-foot orthosis
    Davis, R
    Houdayer, T
    Andrews, B
    Barriskill, A
    ARTIFICIAL ORGANS, 1999, 23 (05) : 418 - 420
  • [32] Design of Wearable System for Closed-Loop Control of Gait Restoration System by Functional Electrical Stimulation
    Arrofiqi, Fauzan
    Arifin, Achmad
    Indrajaya, Benicditus
    2015 INTERNATIONAL SEMINAR ON INTELLIGENT TECHNOLOGY AND ITS APPLICATIONS (ISITIA), 2015, : 131 - 136
  • [33] The Practical Utility of Functional Electrical Stimulation Exercise for Cardiovascular Health in Individuals with Spinal Cord Injury
    Ely, Matthew R.
    Taylor, J. Andrew
    CURRENT PHYSICAL MEDICINE AND REHABILITATION REPORTS, 2021, 9 (03) : 154 - 162
  • [34] The Practical Utility of Functional Electrical Stimulation Exercise for Cardiovascular Health in Individuals with Spinal Cord Injury
    Matthew R. Ely
    J. Andrew Taylor
    Current Physical Medicine and Rehabilitation Reports, 2021, 9 : 154 - 162
  • [35] Chronic, closed-loop, cervical epidural stimulation elicits diaphragm motor plasticity after spinal cord injury
    Malone, Ian
    Kelly, Mia
    Nosacka, Rachel
    Nash, Marissa
    Mitchell, Gordon
    Otto, Kevin
    Dale, Erica
    FASEB JOURNAL, 2021, 35
  • [36] An Exploratory Investigation on the Use of Closed-Loop Electrical Stimulation to Assist Individuals with Stroke to Perform Fine Movements with Their Hemiparetic Arm
    Lew, Brian
    Alavi, Nezam
    Randhawa, Bubblepreet K.
    Menon, Carlo
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2016, 4
  • [37] Control of standing balance at leaning postures with functional neuromuscular stimulation following spinal cord injury
    Audu, Musa L.
    Odle, Brooke M.
    Triolo, Ronald J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (02) : 317 - 330
  • [38] Restoring standing capabilities with feedback control of functional neuromuscular stimulation following spinal cord injury
    Nataraj, Raviraj
    Audu, Musa L.
    Triolo, Ronald J.
    MEDICAL ENGINEERING & PHYSICS, 2017, 42 : 13 - 25
  • [39] Control of standing balance at leaning postures with functional neuromuscular stimulation following spinal cord injury
    Musa L. Audu
    Brooke M. Odle
    Ronald J. Triolo
    Medical & Biological Engineering & Computing, 2018, 56 : 317 - 330
  • [40] MONITORING OF SPASTICITY AND FUNCTIONAL ABILITY IN INDIVIDUALS WITH INCOMPLETE SPINAL CORD INJURY WITH A FUNCTIONAL ELECTRICAL STIMULATION CYCLING SYSTEM
    Reichenfelser, Werner
    Hackl, Harald
    Hufgard, Josef
    Kastner, Josef
    Gstaltner, Karin
    Gfoehler, Margit
    JOURNAL OF REHABILITATION MEDICINE, 2012, 44 (05) : 444 - 449