Closed-Loop Control of Functional Electrical Stimulation-Assisted Arm-Free Standing in Individuals With Spinal Cord Injury: A Feasibility Study

被引:32
|
作者
Vette, Albert H. [1 ,2 ]
Masani, Kei [2 ]
Kim, Joon-Young [2 ,3 ]
Popovic, Milos R. [2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Rehabil Engn Lab, Toronto, ON M5S 3G9, Canada
[2] Lyndhurst Ctr, Toronto Rehabil Inst, Toronto, ON, Canada
[3] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G9, Canada
来源
NEUROMODULATION | 2009年 / 12卷 / 01期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Arm-free standing; functional electrical stimulation; multibody dynamics; neuroprosthesis; proportional and derivative controller; sensory-motor time delay; spinal cord injury; INVERTED PENDULUM; QUIET; DESIGN; TORQUE;
D O I
10.1111/j.1525-1403.2009.00184.x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The purpose of the present study was to show that the design of a neuroprosthesis for unsupported (arm-free) standing is feasible. We review findings suggesting that a closed-loop controlled functional electrical stimulation (FES) system should be able to facilitate arm-free quiet standing in individuals with spinal cord injury (SCI). Particularly, this manuscript identifies: 1) a control strategy that accurately mimics the strategy healthy individuals apply to regulate the ankle joint position during quiet standing and 2) the degrees of freedom (DOF) of the redundant, closed-chain dynamic system of bipedal stance that have to be regulated to facilitate stable standing. First, we utilized a single DOF model of quiet standing (inverted pendulum) to analytically identify a proportional and derivative (PD) feedback controller that regulates the ankle torque in a physiologic manner despite a long sensory-motor time delay. Second, these theoretic results were experimentally validated by implementing the proposed PD controller to stabilize an individual with SCI during quiet standing. Third, a realistic, three-dimensional dynamic model of quiet standing with 12 DOF was used to determine the optimal combination of the minimum number of DOF that need to be regulated with the PD controller to ensure stability during quiet standing. Finally, perturbation simulations confirmed that the kinematics of this system are similar to those of healthy individuals during perturbed standing. The presented results suggest that stable standing can be achieved in individuals with SCI by controlling only six DOF in the lower limbs using FES, and that a PD controller actuating these DOF can stabilize the system despite a long sensory-motor time delay. Our finding that not all DOF in the lower limbs need to be regulated is particularly relevant for individuals with complete SCI, because some of their muscles may be denervated or difficult to access.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [1] Closed-loop control of FES-assisted arm-free paraplegic standing: A feasibility study
    Vette, AH
    Kim, JY
    Masani, K
    Popovic, MR
    Eurocon 2005: The International Conference on Computer as a Tool, Vol 1 and 2 , Proceedings, 2005, : 37 - 40
  • [2] Oxygen Consumption during Functional Electrical Stimulation-Assisted Exercise in Persons with Spinal Cord Injury
    Hettinga, Dries M.
    Andrews, Brian J.
    SPORTS MEDICINE, 2008, 38 (10) : 825 - 838
  • [3] EVALUATION OF CLOSED-LOOP CONTROL SYSTEM FOR RESTORING STANDING AND SITTING FUNCTIONS BY FUNCTIONAL ELECTRICAL STIMULATION
    Liu, Cheng-Liang
    Yu, Chung-Huang
    Chen, Shih-Ching
    Chen, Chang-Hung
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2005, 17 (01): : 19 - 26
  • [4] Step Ergometer Training Augmented With Functional Electrical Stimulation in Individuals With Chronic Spinal Cord Injury: A Feasibility Study
    Tefertiller, Candy
    Gerber, Don
    ARTIFICIAL ORGANS, 2017, 41 (11) : E196 - E202
  • [5] Feasibility of functional electrical stimulation for control of seated posture after spinal cord injury: A simulation study
    Wilkenfeld, Ari J.
    Audu, Musa L.
    Triolo, Ronald J.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2006, 43 (02): : 139 - 151
  • [6] Closed-loop control using a stretch sensor for restoration of standing with functional electrical stimulation in complete paraplegia
    Shimada, Y
    Sato, K
    Matsunaga, T
    Tsutsumi, Y
    Misawa, A
    Ando, S
    Minato, T
    Sato, M
    Chida, S
    Hatakeyama, K
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2001, 193 (03): : 221 - 227
  • [7] Feasibility of closed-loop controller for righting seated posture after spinal cord injury
    Murphy, Julie O.
    Audu, Musa L.
    Lombardo, Lisa M.
    Foglyano, Kevin M.
    Triolo, Ronald J.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (05): : 747 - 760
  • [8] A Comparison of Closed-Loop Control Algorithms for Regulating Electrically Stimulated Knee Movements in Individuals With Spinal Cord Injury
    Lynch, Cheryl L.
    Popovic, Milos R.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (04) : 539 - 548
  • [9] Clinical experience with functional electrical stimulation-assisted gait with parastep in spinal cord-injured patients
    Brissot, R
    Gallien, P
    Le Bot, MP
    Beaubras, A
    Laisné, D
    Beillot, J
    Dassonville, J
    SPINE, 2000, 25 (04) : 501 - 508
  • [10] Functional Electrical Stimulation Control of Standing and Stepping After Spinal Cord Injury: A Review of Technical Characteristics
    Braz, Gustavo P.
    Russold, Michael
    Davis, Glen M.
    NEUROMODULATION, 2009, 12 (03): : 180 - 190