Signal Alteration of the Cochlear Perilymph on 3 Different Sequences after Intratympanic Gd-DTPA Administration at 3 Tesla: Comparison of 3D-FLAIR, 3D-T1-weighted Imaging, and 3D-CISS

被引:10
|
作者
Yamazaki, Masahiro [1 ]
Naganawa, Shinji [1 ]
Kawai, Hisashi [1 ]
Nihashi, Takashi [1 ]
Nakashima, Tsutomu [2 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Otorhinolaryngol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
关键词
cochlea; FLAIR; high resolution; intratympanic gadolinium injection; magnetic resonance imaging; SENSORINEURAL HEARING-LOSS; MENIERES-DISEASE; ENDOLYMPHATIC HYDROPS; PROTEIN-CONCENTRATION; MIDDLE-EAR; FLUID; VISUALIZATION; DEXAMETHASONE; GENTAMICIN; DEAFNESS;
D O I
10.2463/mrms.9.65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T-1-weighted imaging (T1WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Methods: Twenty-one patients underwent 3D-FLAIR, 3D-T1WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). Results: The CM ratio of the injected side (3.00 +/- 1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83 +/- 0.30, range, 0.36 to 1.58 on 3D-T1WI) was significantly higher than that of the non-injected side (0.52 +/- 0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49 +/- 0.11, range, 0.30 to 0.71 on 3D-T1WI) on 3D-FLAIR and 3D-T1WI (P < 0.001), although no significant difference was observed on 3D-CISS (10.03 +/- 2.19, range, 5.19 to 14.98, on the injected side; 9.52 +/- 1.63 range, 7.48 to 13.48, on the non-injected side) (P = 0.11). The mean contrast value on 3D-FLAIR (5.93 +/- 2.57, range, 1.22 to 11.05) was significantly higher than that on 3D-T1WI (1.73 +/- 0.60, range, 0.98 to 3.09) (P < 0.001). Conclusion: The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [1] Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T
    Shinji Naganawa
    Tokiko Koshikawa
    Tatsuya Nakamura
    Hisashi Kawai
    Hiroshi Fukatsu
    Takeo Ishigaki
    Tomomi Komada
    Katsuya Maruyama
    Osamu Takizawa
    European Radiology, 2004, 14 : 1901 - 1908
  • [2] Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T
    Naganawa, S
    Koshikawa, T
    Nakamura, T
    Kawai, H
    Fukatsu, H
    Ishigaki, T
    Komada, T
    Maruyama, K
    Takizawa, O
    EUROPEAN RADIOLOGY, 2004, 14 (10) : 1901 - 1908
  • [3] 3D-Flair sequence at 3T in cochlear otosclerosis
    Francesco Lombardo
    Sara De Cori
    Gayane Aghakhanyan
    Domenico Montanaro
    Daniele De Marchi
    Francesca Frijia
    Susanna Fortunato
    Francesca Forli
    Dante Chiappino
    Stefano Berrettini
    Raffaello Canapicchi
    European Radiology, 2016, 26 : 3744 - 3751
  • [4] 3D-Flair sequence at 3T in cochlear otosclerosis
    Lombardo, Francesco
    De Cori, Sara
    Aghakhanyan, Gayane
    Montanaro, Domenico
    De Marchi, Daniele
    Frijia, Francesca
    Fortunato, Susanna
    Forli, Francesca
    Chiappino, Dante
    Berrettini, Stefano
    Canapicchi, Raffaello
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3744 - 3751
  • [5] 3D MR Cisternography to Identify Distal Dural Rings: Comparison of 3D-CISS and 3D-SPACE Sequences
    Watanabe, Yoshiyuki
    Makidono, Akari
    Nakamura, Miho
    Saida, Yukihisa
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (01) : 29 - 32
  • [6] Comparison between high-resolution 3D-IR with real reconstruction and 3D-flair sequences in the assessment of endolymphatic hydrops in 3 tesla
    Suarez Vega, Victor Manuel
    Dominguez, Pablo
    Caballeros Lam, Fanny Meylin
    Leal, Jose Ignacio
    Perez-Fernandez, Nicolas
    ACTA OTO-LARYNGOLOGICA, 2020, 140 (11) : 883 - 888
  • [7] 3D-constructive interference into steady state (3D-CISS) labyrinth signal alteration in patients with vestibular schwannoma
    Wagner, Franca
    Herrmann, Evelyn
    Wiest, Roland
    Raabe, Andreas
    Bernasconi, Corrado
    Caversaccio, Marco
    Vibert, Dominique
    AURIS NASUS LARYNX, 2018, 45 (04) : 702 - 710
  • [8] Establishing Normal Diameter Range of the Cochlear and Facial Nerves with 3D-CISS at 3T
    Nakamichi, Rei
    Yamazaki, Masahiro
    Ikeda, Mitsuru
    Isoda, Haruo
    Kawai, Hisashi
    Sone, Michihiko
    Nakashima, Tsutomu
    Naganawa, Shinji
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2013, 12 (04) : 241 - 247
  • [9] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [10] Visualization of Endolymphatic Hydrops after Intratympanic Injection of Gd-DTPA: Comparison of 2D and 3D Real Inversion Recovery Imaging
    Naganawa, Shinji
    Sone, Michihiko
    Yamazaki, Masahiro
    Kawai, Hisashi
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (02) : 101 - 106