Influence of selected factors on performance of amperometric glucose biosensor

被引:0
|
作者
LegawiecJarzyna, M
Zawicki, I
机构
来源
OPTOELECTRONIC AND ELECTRONIC SENSORS II | 1997年 / 3054卷
关键词
glucose biosensor; performance; test measurements;
D O I
10.1117/12.266712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effects of different ways of sample feed to the sensor, types of used membranes, extent of stretching the membrane pack by working electrode and timing of excitation voltage on performance of amperometric glucose biosensor with oxygen indicating electrode were investigated. In the sensors, enzymatic membranes containing immobilised glucose oxidase and some auxiliary membranes constituted an easily detachable laminated pack. In one of the tested sensors position of the membrane pack with respect to working electrode was adjustable. It was found that the above factors, except the timing of excitation voltage, have not essential influence on performance of O-2 - type glucose biosensor.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [31] HPLC determination of selected amines with enzymatic biosensor and amperometric detection
    Szewczynska, M
    Wcislo, M
    Trojanowicz, M
    Saar, J
    Dainese, E
    Compagnone, D
    CHEMIA ANALITYCZNA, 2003, 48 (03): : 591 - 606
  • [32] GLUCOSE-OXIDASE IMMOBILIZED IN POLYURETHANE MATRIX - A BIOSENSOR FOR AMPEROMETRIC ESTIMATION OF GLUCOSE
    ALVA, S
    PHADKE, RS
    GOVIL, G
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1993, 70 (4-5) : 403 - 408
  • [33] Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction
    Zhang, Juanjuan
    Wang, Chengyan
    Chen, Shihong
    Yuan, Dehua
    Zhong, Xia
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 52 (03) : 134 - 140
  • [34] Development of an Amperometric-Based Glucose Biosensor to Measure the Glucose Content of Fruit
    Ang, Lee Fung
    Por, Lip Yee
    Yam, Mun Fei
    PLOS ONE, 2015, 10 (03):
  • [35] Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration
    Yan, Qinyi
    Peng, Bo
    Su, Gang
    Cohan, Bruce E.
    Major, Terry C.
    Meyerhoff, Mark E.
    ANALYTICAL CHEMISTRY, 2011, 83 (21) : 8341 - 8346
  • [36] Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
    Valdes-Ramirez, Gabriela
    Galicia, Laura
    MOLECULES, 2021, 26 (12):
  • [37] Silver Nanoparticles as a Glucose Oxidase Immobilization Matrix for Amperometric Glucose Biosensor Construction
    Hsu, Fu-Yin
    Yu, Ding-Syuan
    Chang, Jung-Che
    Chuang, Chia-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (06) : 756 - 760
  • [38] Acrylated polyurethane -: photopolymeric membrane for amperometric glucose biosensor construction
    Puig-Lleixà, C
    Jiménez, C
    Bartrolí, J
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) : 56 - 62
  • [39] Amperometric glucose biosensor based on polymerized ionic liquid microparticles
    Lopez, M. Sanchez-Paniagua
    Mecerreyes, D.
    Lopez-Cabarcos, E.
    Lopez-Ruiz, B.
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (12): : 2320 - 2328
  • [40] A new amperometric glucose biosensor with naphthol green B as mediator
    Zhao, Q
    Yuan, R
    Mo, CL
    Chai, YQ
    Zhong, X
    CHINESE CHEMICAL LETTERS, 2004, 15 (02) : 208 - 211