Influence of selected factors on performance of amperometric glucose biosensor

被引:0
|
作者
LegawiecJarzyna, M
Zawicki, I
机构
来源
OPTOELECTRONIC AND ELECTRONIC SENSORS II | 1997年 / 3054卷
关键词
glucose biosensor; performance; test measurements;
D O I
10.1117/12.266712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effects of different ways of sample feed to the sensor, types of used membranes, extent of stretching the membrane pack by working electrode and timing of excitation voltage on performance of amperometric glucose biosensor with oxygen indicating electrode were investigated. In the sensors, enzymatic membranes containing immobilised glucose oxidase and some auxiliary membranes constituted an easily detachable laminated pack. In one of the tested sensors position of the membrane pack with respect to working electrode was adjustable. It was found that the above factors, except the timing of excitation voltage, have not essential influence on performance of O-2 - type glucose biosensor.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [21] Novel amperometric glucose biosensor based on MXene nanocomposite
    Rakhi, R. B.
    Nayuk, Pranati
    Xia, Chuan
    Alshareef, Husam N.
    SCIENTIFIC REPORTS, 2016, 6
  • [22] Amperometric Biosensor Coupled to Capillary Electrophoresis for Glucose Determination
    Gang Chen
    Yuting Wang
    Pengyuan Yang
    Microchimica Acta, 2005, 150 : 239 - 245
  • [23] IMPROVEMENT OF THE SELECTIVITY OF AN FIA AMPEROMETRIC BIOSENSOR SYSTEM FOR GLUCOSE
    MALE, KB
    LUONG, JHT
    BIOSENSORS & BIOELECTRONICS, 1993, 8 (05): : 239 - 247
  • [24] Pectin coated polyaniline nanoparticles for an amperometric glucose biosensor
    Thakur, Bhawana
    Amarnath, Chellachamy A.
    Sawant, Shilpa N.
    RSC ADVANCES, 2014, 4 (77): : 40917 - 40923
  • [25] A "green" cellulose paper based glucose amperometric biosensor
    Lawrence, Chee Shiong Kuek
    Tan, Swee Ngin
    Floresca, Christina Zerda
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 536 - 541
  • [26] Amperometric biosensor coupled to capillary electrophoresis for glucose determination
    Chen, G
    Wang, YT
    Yang, PY
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 239 - 245
  • [27] Investigation of the Amperometric/Potentiometric Dual Mode Glucose Biosensor
    Liao, Cheng-Wei
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    Hsieh, Jui-Hsiang
    SENSOR LETTERS, 2008, 6 (06) : 836 - 839
  • [28] Amperometric glucose biosensor based on ultrafine platinum nanoparticles
    Cao, Zhaoxia
    Zou, Yongjin
    Xiang, Cuili
    Sun, Li-Xian
    Xu, Fen
    ANALYTICAL LETTERS, 2007, 40 (11) : 2116 - 2127
  • [29] A new amperometric glucose biosensor based on pectin coating
    Sungur, S
    Günendi, G
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2006, 45 (04) : 527 - 531
  • [30] Novel amperometric glucose biosensor based on MXene nanocomposite
    R. B. Rakhi
    Pranati Nayak
    Chuan Xia
    Husam N. Alshareef
    Scientific Reports, 6