Influence of selected factors on performance of amperometric glucose biosensor

被引:0
|
作者
LegawiecJarzyna, M
Zawicki, I
机构
来源
OPTOELECTRONIC AND ELECTRONIC SENSORS II | 1997年 / 3054卷
关键词
glucose biosensor; performance; test measurements;
D O I
10.1117/12.266712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effects of different ways of sample feed to the sensor, types of used membranes, extent of stretching the membrane pack by working electrode and timing of excitation voltage on performance of amperometric glucose biosensor with oxygen indicating electrode were investigated. In the sensors, enzymatic membranes containing immobilised glucose oxidase and some auxiliary membranes constituted an easily detachable laminated pack. In one of the tested sensors position of the membrane pack with respect to working electrode was adjustable. It was found that the above factors, except the timing of excitation voltage, have not essential influence on performance of O-2 - type glucose biosensor.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [1] Genetic modification of glucose oxidase for improving performance of an amperometric glucose biosensor
    Chen, LQ
    Zhang, XE
    Xie, WH
    Zhou, YF
    Zhang, ZP
    Cass, AEG
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (10): : 851 - 857
  • [2] Thermoresponsive amperometric glucose biosensor
    Pinyou, Piyanut
    Ruff, Adrian
    Poeller, Sascha
    Barwe, Stefan
    Nebel, Michaela
    Alburquerque, Natalia Guerrero
    Wischerhoff, Erik
    Laschewsky, Andre
    Schmaderer, Sebastian
    Szeponik, Jan
    Plumere, Nicolas
    Schuhmann, Wolfgang
    BIOINTERPHASES, 2016, 11 (01) : 1 - 7
  • [3] A microflow amperometric glucose biosensor
    Towe, Bruce C.
    Pizziconi, Vincent B.
    Biosensors and Bioelectronics, 1997, 12 (9-10): : 893 - 899
  • [4] AMPEROMETRIC BIOSENSOR FOR GLUCOSE AND LACTATE
    KAISHEVA, A
    ATANASOV, P
    GAMBURZEV, S
    DIMCHEVA, N
    ILIEV, I
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (01) : 53 - 57
  • [5] A microflow amperometric glucose biosensor
    Towe, BC
    Pizziconi, VB
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10): : 893 - 899
  • [6] Atn amperometric glucose biosensor
    Podaru, C
    Bostan, C
    Malide, C
    Neagoe, O
    Simion, M
    Popescu, G
    Garganciuc, D
    Tzetcu, N
    CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 101 - 104
  • [7] Development of an amperometric biosensor on a toothbrush for glucose
    Liu, Yiqun
    Yue, Wei
    Cui, Yue
    SENSORS AND ACTUATORS REPORTS, 2023, 5
  • [8] High-performance glucose amperometric biosensor based on magnetic polymeric bionanocomposites
    Zou, Can
    Fu, Yingchun
    Xie, Qingji
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1277 - 1282
  • [9] Amperometric Glucose Biosensor Based on Carbon Nanoparticles
    Wang Mei-Fang
    Zhang Wei
    Fang Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (01) : 125 - 128
  • [10] An amperometric glucose biosensor based on PEDOT nanofibers
    Cetin, Merih Zeynep
    Camurlu, Pinar
    RSC ADVANCES, 2018, 8 (35): : 19724 - 19731