Detection limit improvement for NDIR ethylene gas detectors using passive approaches

被引:36
|
作者
Sklorz, Adam [1 ]
Janssen, Steffen [1 ]
Lang, Walter [1 ]
机构
[1] Univ Bremen, Inst Microsensors Actuators & Syst IMSAS, D-28359 Bremen, Germany
关键词
NDIR-spectroscopy; Non dispersive infrared; NDIR-detector; Ethylene sensor; Ethylene detector; Detection limit; Broadband IR-sources; Fresnel lenses; Measurement chamber; Infrared gas detection;
D O I
10.1016/j.snb.2012.09.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of passive construction improvements of a NDIR ethylene gas detector on the signal intensity and the detection limits were examined. Rectangularly and conically shaped measurement chambers with and without low-cost Fresnel lenses were used. Also the influence of the choice of the applied broad-band IR-sources was investigated and an equation for detection limit estimation is described. In addition three digital signal processing methods were compared with results provided by a lock-in amplifier. It was shown that the best signal intensity can be achieved using a combination of a conically shaped chamber and Fresnel lenses. The IR-radiation measurement efficiency was improved from 0.8% to 4.2% in the best case. The achieved detection limits were 34 ppmv without and 25 ppmv with the lock in amplifier, the noise equivalent values 6 ppmv and 4 ppmv respectively. These limits match roughly with the calculation results and are comparable with results obtained with white cell systems. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 50 条
  • [1] Strategies for Passive Sensitivity Improvement of NDIR Ethylene Gas Detectors
    Sklorz, Adam
    Lang, Walter
    EUROSENSORS XXV, 2011, 25
  • [2] Note: A NDIR instrument for multicomponent gas detection using the galvanometer modulation
    Wang, Huijie
    Wang, Jing
    Ma, Xiangyun
    Chen, Wenliang
    Chen, Da
    Li, Qifeng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (11):
  • [3] Detection of Ethylene using Gas Chromatographic System
    Zaidi, Nayyer Abbas
    Tahir, M. W.
    Vinayaka, P. P.
    Lucklum, F.
    Vellekoop, M.
    Lang, W.
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 380 - 383
  • [4] DETECTION LIMIT IMPROVEMENT USING MULTIVARIATE CURVE RESOLUTION
    KOWALSKI, BR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 80 - PEST
  • [5] Proposals for gas-detection improvement of the FeMPc monolayer towards ethylene and formaldehyde by using bimetallic synergy
    Ma, Yingying
    Xiong, Huihui
    Zhang, Jianbo
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2024, 26 (15) : 12070 - 12083
  • [6] A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas
    Zaidi, Nayyer Abbas
    Tahir, Muhammad Waseem
    Vellekoop, Michael J.
    Lang, Walter
    SENSORS, 2017, 17 (10)
  • [7] GAS DETECTION BY USING TRANSMITTANCE ESTIMATION AND SEGMENTATION APPROACHES
    Baskurt, Didem Ozisik
    Gur, Yusuf
    Omruuzun, Fatih
    Cetin, Yasemin Yardimci
    REMOTE SENSING TECHNOLOGIES AND APPLICATIONS IN URBAN ENVIRONMENTS, 2016, 10008
  • [8] Flammable gas detection using open path infrared gas detectors: A technical discussion
    Grant, M
    PROCEEDINGS OF THE 43RD ANNUAL ISA ANALYSIS DIVISION SYMPOSIUM, VOL 31, 1998, : 247 - 257
  • [9] Investigation of the Limit of Detection of an Infrared Passive Remote Sensing and Scanning Imaging System for Pollution Gas
    Jiao Yang
    Xu Liang
    Gao Min-guang
    Jin Ling
    Tong Jing-jing
    Li Sheng
    Wei Xiu-li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (10) : 2617 - 2620
  • [10] Early Detection of Combustible Gas Leaks Using Open Path Infrared (IR) Gas Detectors
    Naranjo, Edward
    Baliga, Shankar
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES IX, 2012, 8366