Detection limit improvement for NDIR ethylene gas detectors using passive approaches

被引:36
|
作者
Sklorz, Adam [1 ]
Janssen, Steffen [1 ]
Lang, Walter [1 ]
机构
[1] Univ Bremen, Inst Microsensors Actuators & Syst IMSAS, D-28359 Bremen, Germany
关键词
NDIR-spectroscopy; Non dispersive infrared; NDIR-detector; Ethylene sensor; Ethylene detector; Detection limit; Broadband IR-sources; Fresnel lenses; Measurement chamber; Infrared gas detection;
D O I
10.1016/j.snb.2012.09.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of passive construction improvements of a NDIR ethylene gas detector on the signal intensity and the detection limits were examined. Rectangularly and conically shaped measurement chambers with and without low-cost Fresnel lenses were used. Also the influence of the choice of the applied broad-band IR-sources was investigated and an equation for detection limit estimation is described. In addition three digital signal processing methods were compared with results provided by a lock-in amplifier. It was shown that the best signal intensity can be achieved using a combination of a conically shaped chamber and Fresnel lenses. The IR-radiation measurement efficiency was improved from 0.8% to 4.2% in the best case. The achieved detection limits were 34 ppmv without and 25 ppmv with the lock in amplifier, the noise equivalent values 6 ppmv and 4 ppmv respectively. These limits match roughly with the calculation results and are comparable with results obtained with white cell systems. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 50 条
  • [31] Overview of physical models and statistical approaches for weak gaseous plume detection using passive infrared hyperspectral imagery
    Burr, Tom
    Hengartner, Nicolas
    SENSORS, 2006, 6 (12) : 1721 - 1750
  • [32] Detection limit improvement for Mg in marine foraminiferal calcite by using helium induced X-ray emission
    Beck, L
    Bassinot, F
    Gehlen, M
    Trouslad, P
    Pellegrino, S
    Levi, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 190 : 482 - 487
  • [33] Rapid and sensitive detection of formaldehyde using portable 2-dimensional gas chromatography equipped with photoionization detectors
    Zhu, Hongbo
    She, Jinyan
    Zhou, Menglian
    Fan, Xudong
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 182 - 187
  • [34] GENERATION OF ETHYLENE-OXIDE PERMISSIBLE EXPOSURE LIMIT DATA WITH ON-SITE SAMPLE ANALYSIS USING THE EO SELF-SCAN PASSIVE MONITOR
    PUSKAR, MA
    NOWAK, JL
    HECKER, LH
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1990, 51 (05): : 273 - 279
  • [35] IMPROVEMENT IN DETECTION LIMIT OF ELECTRIC-FIELD MEASUREMENT USING OPTOGALVANIC SIGNALS BY LASER-EXCITED RYDBERG ATOMS
    YAMAGATA, Y
    SUENAGA, K
    MURAOKA, K
    MAEDA, M
    AKAZAKI, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1989, 28 (03): : 565 - 566
  • [36] Improvement of the optical cavity-based biosensor's limit of detection using optimal 3-aminopropyltriethoxysilane process
    Sypabekova, Marzhan
    Kleiss, Jenna
    Hagemann, Aidan
    Schuemann, Sophia
    Wills, Riley
    Zechmann, Bernd
    Kim, Seunghyun
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [37] LIMIT OF DETECTION OF N-15 BY GAS-CHROMATOGRAPHY ATOMIC-EMISSION DETECTION - OPTIMIZATION USING AN EXPERIMENTAL-DESIGN
    DERUAZ, D
    BANNIER, A
    PIONCHON, C
    BOUKRAA, MS
    ELBAST, W
    BRAZIER, JL
    ANALYTICAL LETTERS, 1995, 28 (11) : 2095 - 2113
  • [38] Investigation of passive radar target detection performance improvement by using multiple co-located FM radio transmitters
    Tuysuz, Burak
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2019, 25 (05): : 525 - 531
  • [39] On Autonomous Detection of Pressured Air and Gas Leaks Using Passive IR-Thermography for Mobile Robot Application
    Kroll, Andreas
    Baetz, Werner
    Peretzki, Daniel
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 998 - 1003
  • [40] Selective Detection of Ethylene Gas Using Carbon Nanotube-based Devices: Utility in Determination of Fruit Ripeness
    Esser, Birgit
    Schnorr, Jan M.
    Swager, Timothy M.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (23) : 5752 - 5756