A Versatile Low-Noise Wide-Range Charge-Sensitive Preamplifier for HPGe Detectors

被引:0
|
作者
Pullia, A. [1 ]
Pascovici, G. [1 ]
Ur, C. [1 ]
机构
[1] Univ Milan, Dept Phys, I-20122 Milan, Italy
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A fast low-noise hybrid charge-sensitive preamplifier for HPGe detectors, has been designed for the new array detector "GALILEO" under construction at INFN Legnaro National Laboratory (Italy). The preamplifier includes an over-threshold fast-reset circuitry that greatly reduces the dead time due to preamplifier and/or ADC saturation. A 1-bit digital output signal is provided in LVDS or CMOS format, whose width yields an indirect precise measurement of the large over-threshold signals. Combining the under- and over-threshold working modes an unprecedented spectroscopic dynamic range is obtained of 10(5), from 0.1 fC to 10 pC, i.e. from similar to 2 keV to 180 MeV of equivalent energy in germanium. A fast analogue signal is optionally provided as a trigger for ancillary detectors. The preamplifier is optimized to feature low noise, fast rise time and wide amplitude range when connected to anode detector electrodes. It includes a fast differential buffer for low-noise signal transmission to a remote ADC, with a preset common-mode DC component, that can be adjusted to match the ADC requirement. The rise time, as measured at the test bench, is as fast as 7.5 ns, with a detector capacitance of 23 pF and with a 5m 50 Omega twisted-pair cable connecting the preamplifier to the ADC. With its input transistor working at 150K the preamplifier features an intrinsic noise of similar to 90 electrons r. m. s., i.e. similar to 600eV fwhm in germanium, and a noise slope of 8eV/pF.
引用
收藏
页码:815 / 818
页数:4
相关论文
共 50 条
  • [41] An ultra-low noise cryogenic CMOS charge sensitive preamplifier for large volume point-contact HPGe detectors
    Deng, Z.
    He, L.
    Liu, F.
    Liu, Y.
    Li, Y.
    Yue, Q.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [42] Ultra-Low Power CMOS Charge-Sensitive Preamplifier
    Zhou Yunbo
    Yu Zongguang
    Yang Yu
    INTELLIGENCE COMPUTATION AND EVOLUTIONARY COMPUTATION, 2013, 180 : 975 - 982
  • [43] LOW-NOISE CHARGE-SENSITIVE PRE-AMPLIFIER FOR FAST PULSE COUNTING
    GRAINGER, G
    BEDFORD, DK
    ELECTRONICS LETTERS, 1978, 14 (05) : 126 - 127
  • [44] A versatile high-speed bipolar charge-sensitive preamplifier for calorimeter applications
    Baschirotto, A
    Castello, R
    Pessina, G
    Rancoita, PG
    Seidman, A
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (04) : 635 - 639
  • [45] LOW-NOISE PREAMPLIFIER FOR GE (LI) RADIATION DETECTORS
    PANITKIN, YG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (01): : 146 - &
  • [47] A ultra fast hybrid charge-sensitive preamplifier for high-capacitance detectors
    Boiano, C.
    Bassini, R.
    Pagano, A.
    Pullia, A.
    Riboldi, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 338 - +
  • [48] Interfacing low-noise charge-sensitive preamplifiers to high-resolution flash ADCs
    Pullia, Alberto
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 880 - 884
  • [49] A FULLY INTEGRATED LOW-NOISE HEMT CHARGE PREAMPLIFIER
    BERTUCCIO, G
    DEGERONIMO, G
    LONGONI, A
    LAUXTERMANN, S
    RUNGE, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 592 - 595
  • [50] A low power, charge-sensitive preamplifier integrated with a silicon nanowire biosensor
    Bhattacharjee, Abhiroop
    Kandpal, Kavindra
    2021 IEEE LATIN AMERICA ELECTRON DEVICES CONFERENCE (LAEDC), 2021,