A Versatile Low-Noise Wide-Range Charge-Sensitive Preamplifier for HPGe Detectors

被引:0
|
作者
Pullia, A. [1 ]
Pascovici, G. [1 ]
Ur, C. [1 ]
机构
[1] Univ Milan, Dept Phys, I-20122 Milan, Italy
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A fast low-noise hybrid charge-sensitive preamplifier for HPGe detectors, has been designed for the new array detector "GALILEO" under construction at INFN Legnaro National Laboratory (Italy). The preamplifier includes an over-threshold fast-reset circuitry that greatly reduces the dead time due to preamplifier and/or ADC saturation. A 1-bit digital output signal is provided in LVDS or CMOS format, whose width yields an indirect precise measurement of the large over-threshold signals. Combining the under- and over-threshold working modes an unprecedented spectroscopic dynamic range is obtained of 10(5), from 0.1 fC to 10 pC, i.e. from similar to 2 keV to 180 MeV of equivalent energy in germanium. A fast analogue signal is optionally provided as a trigger for ancillary detectors. The preamplifier is optimized to feature low noise, fast rise time and wide amplitude range when connected to anode detector electrodes. It includes a fast differential buffer for low-noise signal transmission to a remote ADC, with a preset common-mode DC component, that can be adjusted to match the ADC requirement. The rise time, as measured at the test bench, is as fast as 7.5 ns, with a detector capacitance of 23 pF and with a 5m 50 Omega twisted-pair cable connecting the preamplifier to the ADC. With its input transistor working at 150K the preamplifier features an intrinsic noise of similar to 90 electrons r. m. s., i.e. similar to 600eV fwhm in germanium, and a noise slope of 8eV/pF.
引用
收藏
页码:815 / 818
页数:4
相关论文
共 50 条
  • [31] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Jakobson, CG
    Nemirovsky, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 20 - 25
  • [32] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Technion-Israel Inst of Technology, Haifa, Israel
    IEEE Trans Nucl Sci, 1 (20-25):
  • [33] FAST LOW-NOISE CHARGE PREAMPLIFIER
    KARLOVAC, N
    MAYHUGH, TL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 327 - 334
  • [34] A Flexible, Low-noise Charge-sensitive Amplifier for Particle Tracking Application
    Kasinski, Krzysztof
    Kleczek, Rafal
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS (MIXDES 2016), 2016, : 124 - 129
  • [35] TRANSISTOR LOW-NOISE PREAMPLIFIER FOR SEMICONDUCTOR DETECTORS
    KULAKOV, FM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (06): : 1493 - &
  • [36] LOW-NOISE WIDEBAND PREAMPLIFIER FOR PHOTOVOLTAIC DETECTORS
    WALTER, TJ
    GAMO, H
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (05) : 726 - &
  • [37] Low-noise CMOS Charge Preamplifier for X-ray Spectroscopy Detectors
    Bombelli, L.
    Fiorini, C.
    Frizzi, T.
    Nava, R.
    Greppi, A.
    Longoni, A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 135 - 138
  • [38] A wide bandwidth, high linearity hybrid charge-sensitive preamplifier for high-capacitance silicon detectors
    Bassini, R
    Boiano, C
    Pagano, A
    Pullia, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1224 - 1227
  • [39] Design of an Integrated Low-Noise, Low-Power Charge Sensitive Preamplifier for γ and particle spectroscopy with solid state detectors
    Capra, S.
    Mengoni, D.
    Aliaga, R. J.
    Gadea, A.
    Gonzalez, V.
    Pullia, A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [40] Design of an Integrated Low-Noise Ultra-Fast Charge-Sensitive Micro-Probe for Semiconductor Detectors
    Pullia, A.
    Capra, S.
    Frontini, E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4179 - 4183