Survey on the indoor air of the underground space

被引:0
|
作者
Qu, GL [1 ]
Yue, LJ [1 ]
Min, YQ [1 ]
Ma, GH [1 ]
Li, FR [1 ]
机构
[1] Inst Chem Def, Beijing 102205, Peoples R China
关键词
the indoor air of the underground space; formaldehyde; benzene; toluene; xylene; volatile organic compounds;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The volatile organic compounds (VOCs) in different underground spaces were surveyed, the results showed that more than 60 kinds of VOCs were ubiquitous. On this basis, aiming at the underground marks, the hotels, the parks, the offices and the subway, the further quantitative analysis was processed. The quantitative analysis results indicated that organic compounds such as formaldehyde, benzene, toluene and xylene etc. were the major pollutants in the underground space. According to the limit concentration of formaldehyde, benzene, toluene and xylene in the Quality Standards of Indoor Air (GB/T18883-2002)([i]) which is issued by the Chinese National Quality Intendance Quarantine Agency, Sanitation Office, National Environment Protection Agency on November 19th 2002 and. implemented on March 1st 2003, the order of the concentrations of formaldehyde is the underground mark, the office, the park, the hotel in turn, the formaldehyde's concentrations of the park and the hotel are close. But all of the analysis results have not exceeded the limit concentration. The concentrations of benzene in the surveyed underground space are not exceed the standards except the parks, the rate of superscale is 75%. The superscale rates of toluene are 7% in subway, 83% in the parks, 84% in the underground marks and 0% in the hotels and offices respectively. The superscale rates of xylene are 11% in the underground mark, 42% in the park and 0% in the hotel, subway and office respectively. It can be concluded that the air quality of underground hotels, offices, subway are better, the contamination of the underground marks and the parks are severity, the series compounds of benzene are the main contaminations in the parks.
引用
收藏
页码:957 / 965
页数:9
相关论文
共 50 条
  • [31] Measurement and Dynamic Simulation of Underground Parking Garage to Examine the Indoor Air Temperature
    Misovychova, Eva
    Ingeli, Rastislav
    Bosak, Lukas
    SLOVAK JOURNAL OF CIVIL ENGINEERING, 2025, 33 (01) : 19 - 33
  • [32] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [33] Study on the Quantitative Evaluation of Underground Space's Air Quality
    Di, Yanqiang
    Huang, Tao
    Zhao, Yu
    Xie, Qian
    2009 INTERNATIONAL CONFERENCE ON ENGINEERING COMPUTATION, 2009, : 17 - +
  • [34] Survey of indoor air pollution and health symptoms at residential buildings
    Sarkar, Sreemoyee
    Nandy, Abantika
    Talapatra, Soumendra Nath
    Basu, Rajlaxmi
    Mukhopadhyay, Aniruddha
    INTERNATIONAL LETTERS OF NATURAL SCIENCES, 2014, 13 : 17 - 30
  • [35] Survey Measures of Indoor Air Quality: A Birth Outcomes Study
    Ghosh, J.
    Wilhelm, M.
    Ritz, B.
    EPIDEMIOLOGY, 2008, 19 (06) : S219 - S219
  • [36] Survey on indoor air quality in operation room of satellites and fairings
    Tani, H
    Aoki, T
    Tanabe, S
    Taguchi, H
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 669 - 674
  • [37] Numerical simulation of air distribution in a complex geometries indoor space
    Sun, Jian
    Tang, Guangfa
    Li, Nianping
    Liu, Yunchuan
    Nuantong Kongtiao/HV & AC, 2002, 32 (02):
  • [38] Study on Indoor Air Quality in the Education Building Teaching Space
    Xu, Xiaokun
    Yan, Zengfeng
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 175 - 184
  • [39] Urban Air Mobility Noise: Further Considerations on Indoor Space
    Kim, JungHoon
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (18)
  • [40] Sensor fault identification and reconstruction of indoor air quality (IAQ) data using a multivariate non-Gaussian model in underground building space
    Kim, MinJeong
    Liu, Hongbin
    Kim, Jeong Tai
    Yoo, ChangKyoo
    ENERGY AND BUILDINGS, 2013, 66 : 384 - 394