Survey on indoor air quality in operation room of satellites and fairings

被引:0
|
作者
Tani, H
Aoki, T
Tanabe, S
Taguchi, H
机构
[1] Waseda Univ, Dept Architecture, Shinjuku Ku, Tokyo 1698555, Japan
[2] JAXA, Dept Ground Facil, Tsukuba, Ibaraki 3058505, Japan
关键词
satellite; contamination; NVR; particulate matter; SVOC;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In space development, ambient contaminations might have negative influence on the performance and function of h spacecraft and onboard equipment. In this study, for the purpose of figuring out indoor air quality in operation nd room of satellites and collecting basic data, organic compounds emitted from interior materials of the 2 Spacecraft and Fairing Assembly building (SFA2) and several observations of indoor air quality had been done in SFA2. In consequence, Conductive floor was supposed to be the main source of SVOC. As to Non Volatile Residue (NVR) and particulate matter, each result satisfied qualification of contamination control standard in Japan, and concentration of semivolatile organic compounds (SVOC) was far less than the guideline by the Ministry of Health, Labor and Welfare of Japan, that is based on human health. However, they increased after a year from the completion. Therefore, it was thought that SVOC should be paid long term attention.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [1] Impact of room fragrance products on indoor air quality
    Uhde, Erik
    Schulz, Nicole
    ATMOSPHERIC ENVIRONMENT, 2015, 106 : 492 - 502
  • [2] Indoor air quality investigations in hospital patient room
    Lawrence, I. Daniel
    Jayabal, S.
    Thirumal, P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2018, 27 (1-2) : 124 - 138
  • [3] Indoor air quality investigations in hospital patient room
    Daniel Lawrence I.
    Jayabal S.
    Thirumal P.
    Daniel Lawrence, I. (danilawernce@gmail.com), 2018, Inderscience Publishers, 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (27) : 124 - 138
  • [4] Investigation of health risk assessment sevoflurane on indoor air quality in the operation room in Ahvaz city, Iran
    Neisi, Abdolkazem
    Albooghobeish, Masoumeh
    Geravandi, Sahar
    Behrooz, Hamid Reza Adeli
    Mahboubi, Mohammad
    Khaniabad, Yusef Omidi
    Valipour, Aliasghar
    Karimyan, Azimeh
    Mohammadi, Mohammad Javad
    Farhadi, Majid
    Yari, Ahmad Reza
    Ghomeishi, Ali
    TOXIN REVIEWS, 2019, 38 (02) : 151 - 159
  • [5] A survey of indoor air quality in public facilities
    Kim, YS
    Roh, YM
    Hong, SC
    Lee, CM
    Jun, HJ
    Kim, JC
    Cho, JH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 833 - 836
  • [6] ECONOMIZER OPERATION AND MAINTENANCE FOR INDOOR AIR-QUALITY
    VENTRESCA, JA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (01): : 26 - &
  • [7] Management of abnormal air quality monitoring in operation room
    Chu, Yuan-Hsin
    Huang, Yi-Ching
    Liu, Fang-Ching
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S252 - S252
  • [8] The effect of an ion generator on indoor air quality in a residential room
    Waring, M. S.
    Siegel, J. A.
    INDOOR AIR, 2011, 21 (04) : 267 - 276
  • [9] Application of a whole room indoor air quality (IAQ) model
    Li, Feng
    Niu, Jianlei
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 849 - 853
  • [10] Indoor Air Quality Evaluation of Isolation Room for Hospital in Thailand
    Tungjai, A.
    Kubaha, K.
    2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 : 858 - 863