Application of Dynamic Models to predict Switching Impulse Withstand Voltages of Long Air Gaps

被引:18
|
作者
Fofana, I. [1 ]
Beroual, A. [2 ]
Rakotonandrasana, J-H. [2 ]
机构
[1] Univ Quebec Chicoutimi, ISOLIME, Chicoutimi, PQ, Canada
[2] Ecole Cent Lyon, AMPERE Lab, CNRS UMR 5005, F-69134 Ecully, France
关键词
Long air gap discharge; mathematical modeling; computer simulation; critical flashover voltage (CFOV); DISCHARGE;
D O I
10.1109/TDEI.2013.6451345
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this paper is to study the critical breakdown voltage or U-50 - corresponding to the 50% probability of breakdown for a single impulse application - of long air-gaps under positive and negative switching impulse voltages, using predictive dynamic models. The knowledge of this important parameter is of practical interest to the design engineer. The models previously developed by the authors are based on equivalent electrical network, gas discharge theories and physical laws. Various gap geometry and atmospheric conditions were considered. The U-50, determined using the up and down method along with other important parameters, were compared to experimental data. Good agreements were found between simulated and experimental results. The results obtained indicate that U-50 prediction is possible, using the proposed models. Knowledge of the gap factor and weather conditions might help applying corrections to determine the breakdown strength under various conditions. These dynamic models might therefore be useful to estimate the required clearances of air gaps in the preliminary design phase over a wide range of geometry and some atmospheric factors; therefore reducing the required full-scale testing.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 50 条
  • [41] Flashover characteristics of long air gaps with negative switching impulses
    Taniguchi, Sakae
    Okabe, Shigemitsu
    Asakawa, Akira
    Shindo, Takatoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (02) : 399 - 406
  • [42] BREAKDOWN PROCESS OF LONG AIR GAPS WITH POSITIVE SWITCHING IMPULSES
    SUZUKI, T
    MIYAKE, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03): : 1021 - 1033
  • [43] Experimental Study on Effects of Rain on Short Air Gaps Discharge With Switching Impulse Voltage
    Wang S.
    Deng C.
    Wang X.
    Chen W.
    Yang G.
    Wang H.
    Lü F.
    Liu Y.
    Zhou J.
    Ding Y.
    Dianwang Jishu/Power System Technology, 2019, 43 (03): : 1092 - 1098
  • [44] Air Breakdown Behavior of Two Series Gaps for Composite Switching Impulse/Alternating Voltage
    王黎明
    关志成
    胡祺昊
    梁曦东
    盛新富
    TsinghuaScienceandTechnology, 2001, (05) : 500 - 502
  • [45] INFLUENCE OF RAIN ON SWITCHING IMPULSE SPARKOVER VOLTAGE OF LARGE-ELECTRODE AIR GAPS
    RIZK, FAM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (04): : 1394 - 1402
  • [47] EFFECT OF WAVEFRONT ON IMPULSE BREAKDOWN VOLTAGES OF SLIGHTLY NONUNIFORM FIELD GAPS IN NITROGEN, AIR AND SF6 .
    Qiu, Y.
    Zhang, M.
    Liu, R.
    Chalmers, I.D.
    IEEE transactions on electrical insulation, 1986, EI-21 (04): : 575 - 578
  • [48] COEFFICIENT OF VARIATION OF POSITIVE-IMPULSE BREAKDOWN OF LONG AIR-GAPS
    MENEMENLIS, C
    HARBEC, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (03): : 916 - 927
  • [49] Description of the Discharge Process in Long Air Gaps Under Lightning Impulse Voltage
    Schubert, Uwe
    Shirvani, Ali
    Schmidt, Uwe
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2454 - 2463
  • [50] BREAKDOWN PHENOMENA OF LONG GAPS UNDER SWITCHING IMPULSE CONDITIONS TEST CIRCUIT PARAMETERS
    NEWI, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (06): : 1921 - 1921