Flashover characteristics of long air gaps with negative switching impulses

被引:28
|
作者
Taniguchi, Sakae [1 ]
Okabe, Shigemitsu [1 ]
Asakawa, Akira [2 ]
Shindo, Takatoshi [2 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Kanagawa 2308510, Japan
[2] Cent Res Inst Elect Power Ind, Kanagawa 2400196, Japan
关键词
switching impulse; negative polarity; flashover characteristics; long air gap;
D O I
10.1109/TDEI.2008.4483458
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The electrogeometric model (EGM) proposed by Armstrong and Whitehead has been used to calculate the lightning shielding features of transmission lines. While the striking distance equation in the EGM uses the 50% flashover voltage characteristics of negative switching impulses for rod-rod gaps, those characteristics for long air gaps have not been sufficiently examined. The present study has therefore focused on clarifying the 50% flashover characteristics of negative switching impulses for long air gaps. Consequently, saturating characteristics have been obtained for rod-plane gaps compared with almost linear characteristics for rod-rod and rod-conductor gaps. Furthermore, new knowledge was obtained indicating that, for air gaps of around 4 to 5 m, the 50% flashover voltage may possibly be lower for rod-plane gaps than for rod-rod and rod-conductor gaps.
引用
收藏
页码:399 / 406
页数:8
相关论文
共 50 条
  • [1] Statistical Characteristics of Breakdowns in Long Air Gaps at Negative Switching Impulses
    Wang, Yu
    An, Yunzhu
    E, Shenglong
    Wen, Xishan
    Lan, Lei
    Chen, Weijiang
    Dai, Min
    Li, Zhijun
    Ye, Qiming
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 779 - 786
  • [2] SWITCHING SURGE FLASHOVER CHARACTERISTICS OF EXTREMELY LONG AIR GAPS
    WATANABE, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (08): : 933 - &
  • [4] Research on typical long air gaps with negative switching impulses (I)-experiments
    Wang, Yu
    Li, Zhijun
    Dai, Min
    Wen, Xishan
    Lan, Lei
    An, Yunzhu
    Ye, Qiming
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (21): : 3534 - 3540
  • [5] INFLUENCE OF FLOATING PARTICLES ON SWITCHING SURGE FLASHOVER CHARACTERISTICS OF LONG AIR GAPS
    HARA, M
    AKAZAKI, M
    ELECTRICAL ENGINEERING IN JAPAN, 1971, 91 (02) : 81 - &
  • [6] Research on typical long air gaps with negative switching impulses (II)-gap factor
    An, Yunzhu, 1600, Chinese Society for Electrical Engineering (34):
  • [7] Research on typical long air gaps with negative switching impulses(III) -statistical character
    Wang, Yu
    An, Yunzhu
    Wen, Xishan
    Lan, Lei
    Dai, Min
    Li, Zhijun
    Dai, Rundong
    Ye, Qiming
    1600, Chinese Society for Electrical Engineering (34): : 6530 - 6535
  • [8] BREAKDOWN PROCESS OF LONG AIR GAPS WITH POSITIVE SWITCHING IMPULSES
    SUZUKI, T
    MIYAKE, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03): : 1021 - 1033
  • [9] UHV TRANSMISSION DESIGN REQUIREMENTS - SWITCHING SURGE FLASHOVER CHARACTERISTICS OF EXTRA LONG AIR GAPS
    BARNES, HC
    WINTERS, DE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (04): : 1579 - &
  • [10] IMPULSE FLASHOVER CHARACTERISTICS OF LONG AIR GAPS AND ATMOSPHERIC CORRECTION
    AIHARA, Y
    HARADA, T
    AOSHIMA, Y
    ITO, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 342 - 348