Research on typical long air gaps with negative switching impulses (II)-gap factor

被引:0
|
作者
机构
[1] An, Yunzhu
[2] Dai, Min
[3] Li, Zhijun
[4] Lan, Lei
[5] Wen, Xishan
[6] Wang, Yu
[7] Ye, Qiming
来源
An, Yunzhu | 1600年 / Chinese Society for Electrical Engineering卷 / 34期
关键词
26;
D O I
10.13334/j.0258-8013.pcsee.2014.24.019
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Research on typical long air gaps with negative switching impulses (I)-experiments
    Wang, Yu
    Li, Zhijun
    Dai, Min
    Wen, Xishan
    Lan, Lei
    An, Yunzhu
    Ye, Qiming
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (21): : 3534 - 3540
  • [2] Research on typical long air gaps with negative switching impulses(III) -statistical character
    Wang, Yu
    An, Yunzhu
    Wen, Xishan
    Lan, Lei
    Dai, Min
    Li, Zhijun
    Dai, Rundong
    Ye, Qiming
    1600, Chinese Society for Electrical Engineering (34): : 6530 - 6535
  • [3] Flashover characteristics of long air gaps with negative switching impulses
    Taniguchi, Sakae
    Okabe, Shigemitsu
    Asakawa, Akira
    Shindo, Takatoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (02) : 399 - 406
  • [4] Statistical Characteristics of Breakdowns in Long Air Gaps at Negative Switching Impulses
    Wang, Yu
    An, Yunzhu
    E, Shenglong
    Wen, Xishan
    Lan, Lei
    Chen, Weijiang
    Dai, Min
    Li, Zhijun
    Ye, Qiming
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 779 - 786
  • [5] BREAKDOWN PROCESS OF LONG AIR GAPS WITH POSITIVE SWITCHING IMPULSES
    SUZUKI, T
    MIYAKE, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03): : 1021 - 1033
  • [6] Numerical Modeling of Electrical Discharges in Long Air Gaps Tested With Positive Switching Impulses
    Diaz, Oscar
    Cooray, Vernon
    Arevalo, Liliana
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (03) : 611 - 621
  • [7] Multiple discharges before leader inception in long air gaps under positive switching impulses
    Zhao, Xiangen
    Lee, Juhyeong
    Liu, Gang
    Jia, Lei
    Liu, Yang
    He, Junjia
    Du, Yaping
    HIGH VOLTAGE, 2023, 8 (01) : 111 - 118
  • [8] BREAKDOWN PROCESS IN ROD-TO-PLANE GAPS WITH NEGATIVE SWITCHING IMPULSES
    SUZUKI, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (04): : 1381 - 1389
  • [9] Breakdown Characteristics of Long Air Gap with Negative Polarity Switching Impulse
    Wang, Yu
    Wen, Xishan
    Lan, Lei
    An, Yunzhu
    Dai, Min
    Gu, Dingxie
    Li, Zhijun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) : 603 - 611
  • [10] INFLUENCE OF NONSTANDARD SWITCHING IMPULSES ON FLASHOVER MECHANISMS OF AN AIR GAP
    LALOT, J
    HUTZLER, B
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (03): : 848 - 856