Quantification of superparamagnetic iron oxide using inversion recovery balanced steady-state free precession

被引:4
|
作者
Pelot, Nicole A. [1 ,2 ]
Bowen, Chris V. [2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Natl Res Council Canada, Inst Biodiagnost Atlantic, Halifax, NS B3H 3A7, Canada
[3] Dalhousie Univ, Dept Phys & Atmospher Sci, Halifax, NS B3H 4R2, Canada
[4] Dalhousie Univ, Sch Biomed Engn, Halifax, NS B3H 4R2, Canada
[5] Dalhousie Univ, Dept Diagnost Radiol, Dept Diagnost Imaging, Queen Elizabeth II Hlth Sci Ctr, Halifax, NS B3K 6A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Magnetic resonance imaging (MRI); Superparamagnetic iron oxide (SPIO); Inversion recovery; Balanced steady-state free precession (bSSFP); TrueFISP; Quantification; T-2; measurement; Relaxometry; MAGNETIC-RESONANCE; RELAXATION-TIMES; CONTRAST AGENTS; LOADED CELLS; TRUE-FISP; MRI; SIGNAL; SSFP; RELAXOMETRY; TRANSIENT;
D O I
10.1016/j.mri.2013.03.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cellular and molecular MRI trafficking studies using superparamagnetic iron oxide (SPIO) have greatly improved non-invasive investigations of disease progression and drug efficacy, but thus far, these studies have largely been restricted to qualitative assessment of hypo- or hyperintense areas near SPIO. In this work, SPIO quantification using inversion recovery balanced steady-state free precession (IR-bSSFP) was demonstrated at 3 T by extracting R-2 values from a monoexponential model (P. Schmitt et al., 2004). A low flip angle was shown to reduce the apparent recovery rate of the IR-bSSFP time course, thus extending the dynamic range of quantification. However, low flip angle acquisitions preclude the use of traditional methods for combining RF phase-cycled images to reduce banding artifacts arising from off-resonance due to B-0 inhomogeneity. To achieve R-2 quantification of SPIO, we present a new algorithm applicable to low flip angle IR-bSSFP acquisitions that is specifically designed to identify on-resonance acquisitions. We demonstrate in this work, using both theoretical and empirical methods, that the smallest estimated R-2 from multiple RF phase-cycled acquisitions correspond well to the on-resonance time course. Using this novel minimum R-2 algorithm, homogeneous R-2 maps and linear R-2 calibration curves were created up to 100 mu g(Fe)/mL with 20 degrees flip angles, despite substantial B-0 inhomogeneity. In addition, we have shown this technique to be feasible for pre-clinical research: the minimum R-2 algorithm was resistant to off-resonance in a single slice mouse R-2 map, whereas maximum intensity projection resulted in banding artifacts and overestimated R-2 values. With the application of recent advances in accelerated acquisitions, IR-bSSFP has the potential to quantify SPIO in vivo, thus providing important information for oncology, immunology, and regenerative medicine MRI studies. Crown Copyright (c) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:953 / 960
页数:8
相关论文
共 50 条
  • [41] Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precession
    McCormack, Erin J.
    Egnor, Michael R.
    Wagshul, Mark E.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 172 - 182
  • [42] Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification
    Peng, Q
    McColl, RW
    Wang, JH
    Chia, JM
    Weatherall, PT
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 263 - 271
  • [43] 6 Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Edelman, Robert R.
    Botelho, Marcos
    Pursnani, Amit
    Giri, Shivraman
    Koktzoglou, Ioannis
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [44] Phase contrast using multiecho steady-state free precession
    Pai, Vinay M.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 419 - 424
  • [45] Analytical Characterization of RF Phase-Cycled Balanced Steady-State Free Precession
    Lauzon, M. Louis
    Frayne, Richard
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2009, 34A (03) : 133 - 143
  • [46] Parameter Estimation Approach to Banding Artifact Reduction in Balanced Steady-State Free Precession
    Bjork, Marcus
    Ingle, R. Reeve
    Gudmundson, Erik
    Stoica, Petre
    Nishimura, Dwight G.
    Barral, Joelle K.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 880 - 892
  • [47] Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases Reply
    Buch, K.
    Rincon, S.
    Caruso, P.
    Kirsch, J. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : E21 - E21
  • [48] Dynamics of 23Na during completely balanced steady-state free precession
    Kharrazian, R
    Jakob, PM
    JOURNAL OF MAGNETIC RESONANCE, 2006, 179 (01) : 73 - 84
  • [49] Intrinsic diffusion sensitivity of the balanced steady-state free precession (bSSFP) imaging sequence
    Baer, Sebastien
    Weigel, Matthias
    von Elverfeldt, Dominik
    Hennig, Juergen
    Leupold, Jochen
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1383 - 1392
  • [50] Noncontrast MR Angiography for Comprehensive Assessment of Abdominopelvic Arteries Using Quadruple Inversion-Recovery Preconditioning and 3D Balanced Steady-State Free Precession Imaging
    Atanasova, Iliyana P.
    Kim, Daniel
    Lim, Ruth P.
    Storey, Pippa
    Kim, Sooah
    Guo, Hua
    Lee, Vivian S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) : 1430 - 1439