Quantification of superparamagnetic iron oxide using inversion recovery balanced steady-state free precession

被引:4
|
作者
Pelot, Nicole A. [1 ,2 ]
Bowen, Chris V. [2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Natl Res Council Canada, Inst Biodiagnost Atlantic, Halifax, NS B3H 3A7, Canada
[3] Dalhousie Univ, Dept Phys & Atmospher Sci, Halifax, NS B3H 4R2, Canada
[4] Dalhousie Univ, Sch Biomed Engn, Halifax, NS B3H 4R2, Canada
[5] Dalhousie Univ, Dept Diagnost Radiol, Dept Diagnost Imaging, Queen Elizabeth II Hlth Sci Ctr, Halifax, NS B3K 6A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Magnetic resonance imaging (MRI); Superparamagnetic iron oxide (SPIO); Inversion recovery; Balanced steady-state free precession (bSSFP); TrueFISP; Quantification; T-2; measurement; Relaxometry; MAGNETIC-RESONANCE; RELAXATION-TIMES; CONTRAST AGENTS; LOADED CELLS; TRUE-FISP; MRI; SIGNAL; SSFP; RELAXOMETRY; TRANSIENT;
D O I
10.1016/j.mri.2013.03.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cellular and molecular MRI trafficking studies using superparamagnetic iron oxide (SPIO) have greatly improved non-invasive investigations of disease progression and drug efficacy, but thus far, these studies have largely been restricted to qualitative assessment of hypo- or hyperintense areas near SPIO. In this work, SPIO quantification using inversion recovery balanced steady-state free precession (IR-bSSFP) was demonstrated at 3 T by extracting R-2 values from a monoexponential model (P. Schmitt et al., 2004). A low flip angle was shown to reduce the apparent recovery rate of the IR-bSSFP time course, thus extending the dynamic range of quantification. However, low flip angle acquisitions preclude the use of traditional methods for combining RF phase-cycled images to reduce banding artifacts arising from off-resonance due to B-0 inhomogeneity. To achieve R-2 quantification of SPIO, we present a new algorithm applicable to low flip angle IR-bSSFP acquisitions that is specifically designed to identify on-resonance acquisitions. We demonstrate in this work, using both theoretical and empirical methods, that the smallest estimated R-2 from multiple RF phase-cycled acquisitions correspond well to the on-resonance time course. Using this novel minimum R-2 algorithm, homogeneous R-2 maps and linear R-2 calibration curves were created up to 100 mu g(Fe)/mL with 20 degrees flip angles, despite substantial B-0 inhomogeneity. In addition, we have shown this technique to be feasible for pre-clinical research: the minimum R-2 algorithm was resistant to off-resonance in a single slice mouse R-2 map, whereas maximum intensity projection resulted in banding artifacts and overestimated R-2 values. With the application of recent advances in accelerated acquisitions, IR-bSSFP has the potential to quantify SPIO in vivo, thus providing important information for oncology, immunology, and regenerative medicine MRI studies. Crown Copyright (c) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:953 / 960
页数:8
相关论文
共 50 条
  • [31] Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases
    Vossough, A.
    Melhem, E. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : E20 - E20
  • [32] Monitoring and Compensating Phase Imperfections in Cine Balanced Steady-State Free Precession
    Fischer, Rudolf Fritz
    Barmet, Christoph
    Rudin, Markus
    Boesiger, Peter
    Pruessmann, Klaas Paul
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1567 - 1579
  • [33] Spin-Locked Balanced Steady-State Free-Precession (slSSFP)
    Witschey, Walter R. T.
    Borthakur, Ari
    Elliott, Mark A.
    Magland, Jeremy
    McArdle, Erin L.
    Wheaton, Andrew
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 993 - 1001
  • [34] Magnetization evolution in balanced steady-state free precession with continuously moving table
    Stafford, Randall B.
    Sabati, Mohammad
    Mahallati, Houman
    Frayne, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : N173 - N184
  • [35] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335
  • [37] Myocardial delayed enhancement imaging using inversion recovery single-shot steady-state free precession: Initial experience
    Li, W
    Li, BSY
    Polzin, JA
    Mai, VM
    Prasad, PV
    Edelman, RR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (02) : 327 - 330
  • [38] Chemical Shift Selective Fat Imaging Using Transition Into Driven Equilibrium Balanced Steady-State Free Precession for Quantification of Adipose Tissue
    Paul, Dominik
    Sommer, Gregor
    Leupold, Jochen
    Hentschel, Michael
    Baumann, Tobias
    Ludwig, Ute
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 475 - 480
  • [39] Phase-sensitive inversion recovery single-shot balanced steady-state free precession for detection of myocardial infarction during a single breathhold
    Huber, Armin
    Hayes, Carmel
    Spannagl, Benedikt
    Rieber, Johannes
    Klauss, Volker
    Schoenberg, Stefan Oswald
    Reiser, Maximilion
    Wintersperger, Bernd Jurgen
    ACADEMIC RADIOLOGY, 2007, 14 (12) : 1500 - 1508
  • [40] Pulmonary relaxometry with inversion recovery ultra-fast steady-state free precession at 1.5T
    Bauman, Grzegorz
    Santini, Francesco
    Pusterla, Orso
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 74 - 82