Accuracy in contouring of small and low contrast lesions: Comparison between diagnostic quality computed tomography scanner and computed tomography simulation scanner-A phantom study

被引:2
|
作者
Ho, Yick Wing [1 ]
Wong, Wing Kei Rebecca [1 ]
Yu, Siu Ki [1 ]
Lam, Wai Wang [1 ]
Geng, Hui [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys & Res Dept, Happy Valley, Hong Kong, Peoples R China
关键词
Computed tomography; Delineation accuracy; RADIOSURGERY; RADIOTHERAPY; DELINEATION;
D O I
10.1016/j.meddos.2012.03.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To evaluate the accuracy in detection of small and low-contrast regions using a high-definition diagnostic computed tomography (CT) scanner compared with a radiotherapy CT simulation scanner. A custom-made phantom with cylindrical holes of diameters ranging from 2-9 mm was filled with 9 different concentrations of contrast solution. The phantom was scanned using a 16-slice multidetector CT simulation scanner (LightSpeed RT16, General Electric Healthcare, Milwaukee, WI) and a 64-slice high-definition diagnostic CT scanner (Discovery CT750 HD, General Electric Healthcare). The low-contrast regions of interest (ROIs) were delineated automatically upon their full width at half maximum of the CT number profile in Hounsfield units on a treatment planning workstation. Two conformal indexes, CIin, and CIout, were calculated to represent the percentage errors of underestimation and overestimation in the automated contours compared with their actual sizes. Summarizing the conformal indexes of different sizes and contrast concentration, the means of CIin, and CIout for the CT simulation scanner were 33.7% and 60.9%, respectively, and 10.5% and 41.5% were found for the diagnostic CT scanner. The mean differences between the 2 scanners' CIin, and CIout were shown to be significant with p < 0.001. A descending trend of the index values was observed as the ROI size increases for both scanners, which indicates an improved accuracy when the ROI size increases, whereas no observable trend was found in the contouring accuracy with respect to the contrast levels in this study. Images acquired by the diagnostic CT scanner allow higher accuracy on size estimation compared with the CT simulation scanner in this study. We recommend using a diagnostic CT scanner to scan patients with small lesions (<1 cm in diameter) for radiotherapy treatment planning, especially for those pending for stereotactic radiosurgery in which accurate delineation of small-sized, low-contrast regions is important for dose calculation. (C) 2012 American Association of Medical Dosimetrists.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 50 条
  • [41] Patient arm position during quantitative bone single-photon emission computed tomography/computed tomography acquisition can affect image quality and quantitative accuracy: a phantom study
    Miyaji, Noriaki
    Miwa, Kenta
    Motegi, Kazuki
    Yamashita, Kosuke
    Terauchi, Takashi
    Onoguchi, Masahisa
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (03) : 267 - 275
  • [42] Accuracy of ultra-high-resolution computed tomography with a 0.3-mm detector for quantitative assessment of coronary artery stenosis grading in comparison with conventional computed tomography: A phantom study
    Yamada, Minoru
    Yamada, Yoshitake
    Nakahara, Takehiro
    Okuda, Shigeo
    Abe, Takayuki
    Kuribayashi, Sachio
    Jinzaki, Masahiro
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2022, 16 (03) : 239 - 244
  • [43] High-quality low-dose cardiovascular computed tomography (CCT) in pediatric patients using a 64-slice scanner
    Cannao, Paola Maria
    Secchi, Francesco
    Ali, Marco
    D'Angelo, Ida Daniela
    Scarabello, Marco
    Di Leo, Giovanni
    Sardanelli, Francesco
    ACTA RADIOLOGICA, 2018, 59 (10) : 1247 - 1253
  • [44] Comparison of Diagnostic Performance and Confidence between Contrast-Enhanced Computed Tomography Scan and Non-Contrast-Enhanced Computed Tomography Plus Abdomen Ultrasound for Hepatic Metastasis in Patients with Breast Cancer
    Noh, Hee Yeon
    Ahn, Su Joa
    Nam, Sang Yu
    Jang, Young Rock
    Chun, Yong Soon
    Park, Heung Kyu
    Choi, Seung Joon
    Choi, Hye Young
    Kim, Jeong Ho
    JOURNAL OF MEDICAL ULTRASOUND, 2022, 30 (02) : 116 - 124
  • [45] Quantitative accuracy of virtual non-contrast images derived from spectral detector computed tomography: an abdominal phantom study
    Jasmin A. Holz
    Hatem Alkadhi
    Kai R. Laukamp
    Simon Lennartz
    Carola Heneweer
    Michael Püsken
    Thorsten Persigehl
    David Maintz
    Nils Große Hokamp
    Scientific Reports, 10
  • [46] Quantitative accuracy of virtual non-contrast images derived from spectral detector computed tomography: an abdominal phantom study
    Holz, Jasmin A.
    Alkadhi, Hatem
    Laukamp, Kai R.
    Lennartz, Simon
    Heneweer, Carola
    Puesken, Michael
    Persigehl, Thorsten
    Maintz, David
    Hokamp, Nils Grosse
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
    Iranmakani, Sepideh
    Jahanshahi, Amir Reza
    Mehnati, Parinaz
    Mortezazadeh, Tohid
    Khezerloo, Davood
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (01): : 64 - 68
  • [48] Comparison of Calcium Scoring Between 64-Multidetector Computed Tomography and 320-Multidetector Computed Tomography Using a Cardiac Phantom: Achieving Consistent Image Quality With Dose Optimization
    Tsai, Sung-Yi
    Ding, Xiao-Hua
    Jin, Shih-Chun
    Yi, Dong-Bo
    Chen, Jyh-Cheng
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 73 - 77
  • [49] Accuracy of Small-Intestine Contrast Ultrasonography, Compared With Computed Tomography Enteroclysis, in Characterizing Lesions in Patients With Crohn's Disease
    Calabrese, Emma
    Zorzi, Francesca
    Onali, Sara
    Stasi, Elisa
    Fiori, Roberto
    Prencipe, Simonetta
    Bella, Antonino
    Petruzziello, Carmelina
    Condino, Giovanna
    Lolli, Elisabetta
    Simonetti, Giovanni
    Biancone, Livia
    Pallone, Francesco
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2013, 11 (08) : 950 - 955
  • [50] Comparison of diagnostic value of technetium 99m-labeled red blood cell computed single photon emission computed tomography/computed tomography (99mTc-RBC SPECT/CT) and contrast-enhanced multidetector computed tomography (MDCT) for small bowel bleeding: a retrospective study
    Wang, Guanyun
    Zhang, Shuxin
    Kan, Ying
    Liu, Jie
    Yang, Jigang
    Wang, Wei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08) : 6087 - 6098