Faulty washers and soiled micropipettors may generate false positive serological results

被引:9
|
作者
Parry, JV [1 ]
Mortimer, PP [1 ]
Friderich, P [1 ]
Connell, JA [1 ]
机构
[1] UNIV BASEL,INST MED MICROBIOL,BASEL,SWITZERLAND
来源
CLINICAL AND DIAGNOSTIC VIROLOGY | 1997年 / 7卷 / 03期
关键词
cross-contamination; false positive results; ELISA washers; micropipettors;
D O I
10.1016/S0928-0197(97)00268-7
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Serological markers such as HBsAg and anti-HIV may be present in serum at very high concentrations and this may give rise to erroneous diagnoses due to cross-contamination. Objectives: To investigate poor equipment maintenance and use; including contamination with human serum, as a potential source of erroneous assay results. Study design: The potential of microtitre plate washers and micropipettors to transfer material between microplate wells and between specimens was examined. For the study of micropipettors we recruited 19 UK diagnostic laboratories. Results: Four out of seven plate washers in use, until adjusted, had the potential to cause false positive HBsAg reactions. The centering of the probes that delivered the wash fluid, delivery pressure, wash volume and the use of a pre-programmed card to direct the washing procedure were important variables. We investigated soiling of tip cones of micropipettors. In every laboratory human Ige could be detected in al least a third of eluates from micropipettor tip cones; only 31 (14%) of 222 showed no evidence of contamination with human serum. Only one laboratory submitted eluates devoid of specific antibodies. Anti-HAV was the marker most commonly found (n = 68), followed by HBsAg (n = 27) and anti-HIV (n = 20). Seven micropipettor eluates from two laboratories were radioactively contaminated. Conclusions: Recommended precautions are regular checking, cleaning and servicing of equipment, care in interpreting weak reactions, reference back to serum left on the clot of the original specimen and testing of a follow up specimen. Poorly maintained immunoassay equipment can readily generate false positive results due to low-level cross-contamination, particularly with the current highly sensitive HBsAg and anti-HIV assays. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 50 条
  • [21] LEPROSY AS CAUSE OF FALSE-POSITIVE RESULTS IN SEROLOGICAL ASSAYS FOR THE DETECTION OF ANTIBODIES TO HIV-1
    ANDRADE, VL
    AVELLEIRA, JC
    MARQUES, A
    VIANNA, FR
    SCHECHTER, M
    INTERNATIONAL JOURNAL OF LEPROSY AND OTHER MYCOBACTERIAL DISEASES, 1991, 59 (01) : 125 - 126
  • [22] False-positive results in studies of changes in fiber diffraction of hair from patients with breast cancer may not be false
    James, V
    JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2003, 95 (02) : 170 - 171
  • [23] Latex contamination in penicillin determinants for skin testing may induce false positive results.
    Terrados, S
    Blanca, M
    Fernandez, J
    Vega, JM
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 97 (01) : 988 - 988
  • [24] Women's attitudes to false positive mammography results - Findings may not apply to United Kingdom
    Carter, JM
    Ghebrehewet, S
    BMJ-BRITISH MEDICAL JOURNAL, 2000, 321 (7273): : 1410 - 1410
  • [25] LOW RATE OF FALSE POSITIVE RESULTS IN SEROLOGICAL SURVEYS FOR INFECTION WITH HIV IN NORMAL YOUNG-ADULT GROUPS
    ZAIDES, VM
    BEREZIN, VE
    BUBNOV, VV
    KLYUSHNIK, SY
    KOROBOV, LI
    BOSCHENKO, YA
    ZHDANOV, VM
    VOPROSY VIRUSOLOGII, 1988, (03) : 298 - 302
  • [26] Dual-Antigen System Allows Elimination of False Positive Results in COVID-19 Serological Testing
    Komarov, Andrei
    Kaznadzey, Anna
    Li, Yue
    Kireeva, Maria
    Mazo, Ilya
    DIAGNOSTICS, 2021, 11 (01)
  • [27] Microdeletion in SNRPN May Lead to False Positive Results for Angelman Syndrome Using Methylation Analysis
    Zhang, B. M.
    Popa, A.
    Ferreira-Gonzalez, A.
    Jennings, L. J.
    Weck, K. E.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (06): : 947 - 947
  • [28] False-positive HIV antibody results with ultrasensitive serological assays in uninfected infants born to mothers with HIV
    Nastouli, Eleni
    Atkins, Mark
    Seery, Paula
    Hamadache, Djamel
    Muir, David
    Lyall, Hermione
    AIDS, 2007, 21 (09) : 1222 - 1223
  • [29] Efficacy of several serological tests and antigens for diagnosis of bovine brucellosis in the presence of false-positive serological results due to Yersinia enterocolitica O:9
    Muñoz, PM
    Marín, CM
    Monreal, D
    González, D
    Garin-Bastuji, B
    Díaz, R
    Mainar-Jaime, RC
    Moriyón, I
    Blasco, JM
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (01) : 141 - 151
  • [30] False Positive Results in SARS-CoV-2 Serological Tests for Samples From Patients With Chronic Inflammatory Diseases
    Kharlamova, Nastya
    Dunn, Nicky
    Bedri, Sahl K.
    Jerling, Svante
    Almgren, Malin
    Faustini, Francesca
    Gunnarsson, Iva
    Ronnelid, Johan
    Pullerits, Rille
    Gjertsson, Inger
    Lundberg, Karin
    Manberg, Anna
    Pin, Elisa
    Nilsson, Peter
    Hober, Sophia
    Fink, Katharina
    Fogdell-Hahn, Anna