Faulty washers and soiled micropipettors may generate false positive serological results

被引:9
|
作者
Parry, JV [1 ]
Mortimer, PP [1 ]
Friderich, P [1 ]
Connell, JA [1 ]
机构
[1] UNIV BASEL,INST MED MICROBIOL,BASEL,SWITZERLAND
来源
CLINICAL AND DIAGNOSTIC VIROLOGY | 1997年 / 7卷 / 03期
关键词
cross-contamination; false positive results; ELISA washers; micropipettors;
D O I
10.1016/S0928-0197(97)00268-7
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Serological markers such as HBsAg and anti-HIV may be present in serum at very high concentrations and this may give rise to erroneous diagnoses due to cross-contamination. Objectives: To investigate poor equipment maintenance and use; including contamination with human serum, as a potential source of erroneous assay results. Study design: The potential of microtitre plate washers and micropipettors to transfer material between microplate wells and between specimens was examined. For the study of micropipettors we recruited 19 UK diagnostic laboratories. Results: Four out of seven plate washers in use, until adjusted, had the potential to cause false positive HBsAg reactions. The centering of the probes that delivered the wash fluid, delivery pressure, wash volume and the use of a pre-programmed card to direct the washing procedure were important variables. We investigated soiling of tip cones of micropipettors. In every laboratory human Ige could be detected in al least a third of eluates from micropipettor tip cones; only 31 (14%) of 222 showed no evidence of contamination with human serum. Only one laboratory submitted eluates devoid of specific antibodies. Anti-HAV was the marker most commonly found (n = 68), followed by HBsAg (n = 27) and anti-HIV (n = 20). Seven micropipettor eluates from two laboratories were radioactively contaminated. Conclusions: Recommended precautions are regular checking, cleaning and servicing of equipment, care in interpreting weak reactions, reference back to serum left on the clot of the original specimen and testing of a follow up specimen. Poorly maintained immunoassay equipment can readily generate false positive results due to low-level cross-contamination, particularly with the current highly sensitive HBsAg and anti-HIV assays. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 50 条
  • [11] Serological diagnosis of Toxoplasma gondii: analysis of false-positive IgG results and implications
    Simon, Loic
    Fillaux, Judith
    Guigon, Aurelie
    Lavergne, Rose-Anne
    Villard, Odile
    Villena, Isabelle
    Marty, Pierre
    Pomares, Christelle
    Carod, Jean-Francois
    Cimon, Bernard
    Donsimoni, Rita
    Ernault, Valerie
    Fricker-Hidalgo, Helene
    Gillon, Juliette
    Godineau, Nadine
    Gonfrier, Geraldine
    Hautecoeur, Marie
    Liguori, Stephane
    Noulard, Marie-Noelle
    Pelloux, Herve
    Poggi, Cecile
    PARASITE, 2020, 27
  • [12] Whole Nucleocapsid Protein of Severe Acute Respiratory Syndrome Coronavirus 2 May Cause False-Positive Results in Serological Assays Reply
    Guo, Li
    Ren, Lili
    Sharma, Lokesh
    Wang, Jianwei
    CLINICAL INFECTIOUS DISEASES, 2021, 72 (07) : 1293 - 1293
  • [13] PCR IN-SITU - ASPECTS WHICH REDUCE AMPLIFICATION AND GENERATE FALSE-POSITIVE RESULTS
    TEO, IA
    SHAUNAK, S
    HISTOCHEMICAL JOURNAL, 1995, 27 (09): : 660 - 669
  • [14] Vortioxetine use may cause false positive immunoassay results for urine methadone
    Uljon, Sacha
    Kataria, Yachana
    Flood, James G.
    CLINICA CHIMICA ACTA, 2019, 499 : 1 - 3
  • [15] Assessment of Morphine Hypersensitivity By Skin Test May Yield False Positive Results
    Blaziene, Audra
    Stankeviciute, R.
    Cerniauskas, K.
    DuBuske, Lawrence M.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2017, 139 (02) : AB38 - AB38
  • [16] Usefulness of urine dipstick tests - Packaging may lead to false positive results
    Edwards, A
    Granier, S
    VanderVoort, J
    BRITISH MEDICAL JOURNAL, 1996, 313 (7063): : 1010 - 1010
  • [17] FOLLOW-UP OF CARRIERS OF BIOLOGICAL FALSE-POSITIVE RESULTS OF SEROLOGICAL TESTS FOR SYPHILIS
    SHINSKY, GE
    PROTOPOPOVA, NE
    NIKITINA, LS
    YUMINOVA, VV
    KONENKOVA, VP
    SARANTSEVA, NM
    KLINICHESKAYA MEDITSINA, 1991, 69 (04): : 75 - 78
  • [18] The Risk of False-Positive Serological Results for Paratuberculosis in Mycobacterium bovis-Infected Cattle
    Didkowska, Anna
    Krajewska-Wedzina, Monika
    Klich, Daniel
    Prolejko, Kinga
    Orlowska, Blanka
    Anusz, Krzysztof
    PATHOGENS, 2021, 10 (08):
  • [20] False-positive mammography results may indicate increased breast cancer risk
    Rose, Sam
    FUTURE ONCOLOGY, 2012, 8 (06) : 647 - 647