Analysis of "Accuracy of a 14-Day Factory Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes"

被引:4
|
作者
Kompala, Tejaswi [1 ]
Neinstein, Aaron B. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Ctr Digital Hlth Innovat, San Francisco, CA 94143 USA
来源
关键词
continuous glucose monitoring; diabetes mellitus; telehealth; digital health; ACCEPTABILITY; CARE;
D O I
10.1177/1932296820967004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study by Alva et al, accuracy of a second-generation factory calibrated continuous glucose monitoring system is evaluated. Compared to the first-generation FreeStyle Libre 14-day system (FSL), accuracy was improved throughout the 14-day wear period, including improved accuracy in hypoglycemia for adults and youth. The addition of optional real-time alerts for hypoglycemia and hyperglycemia as well as an integrated continuous glucose monitor (iCGM) designation by the FDA may further enable users to benefit from using CGM in real time, including in future automated insulin delivery systems. As CGM accuracy, affordability, and accessibility improve, we anticipate increased uptake of CGM by people on intensive insulin therapy, and also potential benefits and expansion into a broader patient population. There are growing opportunities to leverage cloud-connected CGM devices in the increasingly virtual, continuous telehealth-driven diabetes care model, which will require more focus on development and use of data interoperability standards.
引用
收藏
页码:78 / 80
页数:3
相关论文
共 50 条
  • [21] Ambulatory glucose profile analysis of the juvenile diabetes research foundation continuous glucose monitoring dataset-Applications to the pediatric diabetes population
    Forlenza, Gregory P.
    Pyle, Laura L.
    Maahs, David M.
    Dunn, Timothy C.
    PEDIATRIC DIABETES, 2017, 18 (07) : 622 - 628
  • [22] Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System
    Ji, Linong
    Guo, Lixin
    Zhang, Junqing
    Li, Yufeng
    Chen, Zhiyan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 208 - 213
  • [23] Accuracy of continuous glucose monitoring system during exercise in type 2 diabetes
    Figueira, Franciele R.
    Umpierre, Daniel
    Ribeiro, Jorge P.
    Tetelbom, Pedro S.
    Henn, Nicoli T.
    Esteves, Jorge F.
    Schaan, Beatriz D.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 98 (03) : E36 - E39
  • [24] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Vokounova-Honsova, Sarka
    Navratil, Tomas
    Kohlikova, Eva
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1659 - 1669
  • [25] The accuracy of continuous glucose monitoring system by the athlete with diabetes mellitus type 1
    Šárka Vokounová-Honsová
    Tomáš Navrátil
    Eva Kohlíková
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1659 - 1669
  • [26] Accuracy and Safety of the 15-Day CareSens Air Continuous Glucose Monitoring System
    Kim, Kyung-Soo
    Lee, Seung-Hwan
    Yoo, Won Sang
    Park, Cheol-Young
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (04) : 222 - 228
  • [27] Performance of a Factory-Calibrated Real-Time Continuous Glucose Monitoring System Utilizing an Automated Sensor Applicator
    Shah, Viral N.
    Laffel, Lori M.
    Wadwa, R. Paul
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (06) : 428 - 433
  • [28] Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
    Aida, Azusa
    Noto, Hiroshi
    AMERICAN JOURNAL OF CASE REPORTS, 2022, 23
  • [29] Performance of a factory-calibrated, real-time continuous glucose monitoring system during elective abdominal surgery
    Tripyla, Afroditi
    Herzig, David
    Joachim, Dehais
    Nakas, Christos T.
    Amiet, Franziska
    Andreou, Andreas
    Gloor, Beat
    Vogt, Andreas
    Bally, Lia
    DIABETES OBESITY & METABOLISM, 2020, 22 (09): : 1678 - 1682
  • [30] ACCURACY OF THREE FACTORY-CALIBRATED CONTINUOUS GLUCOSE MONITORS DURING INPATIENT AEROBIC EXERCISE AND AT HOME IN INDIVIDUALS WITH TYPE 1 DIABETES
    Lundemose, S.
    Ranjan, A.
    Norgaard, K.
    Laugesen, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A160 - A160