Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device

被引:33
|
作者
Maestri, R [1 ]
Pinna, GD
Robbi, E
Capomolla, S
La Rovere, MT
机构
[1] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Biomed Engn, I-27040 Montescano, PV, Italy
[2] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Cardiol, I-27040 Montescano, PV, Italy
关键词
blood pressure variability; noninvasive baroreflex sensitivity;
D O I
10.1088/0967-3334/26/6/021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To assess the accuracy of spectral indices of arterial pressure variability and baroreflex sensitivity obtained from beat-by-beat noninvasive blood pressure recordings by the Finometer device, we compared these measures with those obtained from intra-arterial recordings. The performance of the Finometer was also compared to the traditional Finapres device. In 19 cardiac disease patients, including myocardial infarction, heart failure and cardiac transplant, we estimated the power of systolic and diastolic pressures in the VLF (0.010.04 Hz), LF (0.04-0.L5 Hz) and HF (0.15-0.45 Hz) bands and computed absolute and percentage errors relative to intra-arterial brachial pressure. We also computed the characteristic frequency of each band (i.e. the barycentric frequency of spectral components identified in the band). The variability of systolic pressure in the VLF and LF bands was markedly overestimated by both the Finometer and Finapres (p < 0.01), with percentage median errors of respectively 130% and 103% (Finometer), and 134% and 78% (Finapres). The HF power was substantially unchanged using the Finometer and reduced using the Finapres (-28%, p < 0.05). The limits of agreement between noninvasive and invasive spectral measurements were wide. Linear system analysis showed that most (> 80%) of the power of noninvasive signals was linearly related to the power of the invasive signal. The characteristic frequency of each band was substantially preserved in both noninvasive signals. The results for diastolic pressure were similar, but the Finapres errors in the VLF and LF bands were lower. Baroreflex sensitivity was significantly underestimated by both devices (Finometer: -31 %, Finapres: -24%). Despite previous studies having shown that brachial artery waveforrn reconstruction performed by the Finometer has improved the accuracy of blood pressure measurement compared to the Finapres device, measurement of blood pressure variability in cardiac disease patients provides worse results in most spectral parameters and a better accuracy only in the HF band of systolic pressure.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [41] NONINVASIVE, CONTINUOUS MEASUREMENT OF THE FINGER ARTERIAL-PRESSURE WITH THE SERVO-PLETHYSMO-MANOMETER FINAPRES
    HARTMANN, B
    BASSENGE, E
    HERZ, 1989, 14 (04) : 251 - 259
  • [42] A comparison of a continuous noninvasive arterial pressure (CNAP (TM)) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU
    Jagadeesh, A. M.
    Singh, Naveen G.
    Mahankali, Subramanyam
    ANNALS OF CARDIAC ANAESTHESIA, 2012, 15 (03) : 180 - 184
  • [43] ERRONEOUS BLOOD-PRESSURE MEASUREMENTS WITH A NONINVASIVE BLOOD-PRESSURE MONITOR
    EHLERS, KC
    GRABENBAUER, SA
    ANESTHESIOLOGY, 1991, 74 (05) : 967 - 967
  • [44] Accuracy of the Braun 2550(UG) device in home blood pressure measurement
    Nolly, H
    Raposo, I
    Nolly, A
    JOURNAL OF HYPERTENSION, 2003, 21 : S23 - S23
  • [45] Measuring orthostatic hypotension with the Finometer device: is a blood pressure drop of one heartbeat clinically relevant?
    van der Velde, Nathalie
    van den Meiracker, Anton H.
    Stricker, Bruno H. Ch.
    van der Cammen, Tischa J. M.
    BLOOD PRESSURE MONITORING, 2007, 12 (03) : 167 - 171
  • [46] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    ABENSTEIN, JP
    STENSRUD, PE
    SPACKMAN, TN
    TARHAN, S
    ANESTHESIOLOGY, 1993, 79 (3A) : A504 - A504
  • [47] Automated blood pressure measurement during ergometric stress testing: Possibilities of Finapres
    Imholz, BPM
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 76 - 80
  • [48] Noninvasive Blood Pressure Measurement in Neonates
    Solevag, Anne Lee
    Saugstad, Ola Didrik
    JOURNAL OF PEDIATRICS, 2021, 235 : 57 - 57
  • [49] Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure measurements during bariatric surgery in severely obese adolescents and young adults
    Joseph D. Tobias
    Chris McKee
    Dan Herz
    Steve Teich
    Paul Sohner
    Julie Rice
    N’Diris Barry
    Marc Michalsky
    Journal of Anesthesia, 2014, 28 : 861 - 865
  • [50] Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure measurements during bariatric surgery in severely obese adolescents and young adults
    Tobias, Joseph D.
    McKee, Chris
    Herz, Dan
    Teich, Steve
    Sohner, Paul
    Rice, Julie
    Barry, N'Diris
    Michalsky, Marc
    JOURNAL OF ANESTHESIA, 2014, 28 (06) : 861 - 865