Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device

被引:33
|
作者
Maestri, R [1 ]
Pinna, GD
Robbi, E
Capomolla, S
La Rovere, MT
机构
[1] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Biomed Engn, I-27040 Montescano, PV, Italy
[2] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Cardiol, I-27040 Montescano, PV, Italy
关键词
blood pressure variability; noninvasive baroreflex sensitivity;
D O I
10.1088/0967-3334/26/6/021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To assess the accuracy of spectral indices of arterial pressure variability and baroreflex sensitivity obtained from beat-by-beat noninvasive blood pressure recordings by the Finometer device, we compared these measures with those obtained from intra-arterial recordings. The performance of the Finometer was also compared to the traditional Finapres device. In 19 cardiac disease patients, including myocardial infarction, heart failure and cardiac transplant, we estimated the power of systolic and diastolic pressures in the VLF (0.010.04 Hz), LF (0.04-0.L5 Hz) and HF (0.15-0.45 Hz) bands and computed absolute and percentage errors relative to intra-arterial brachial pressure. We also computed the characteristic frequency of each band (i.e. the barycentric frequency of spectral components identified in the band). The variability of systolic pressure in the VLF and LF bands was markedly overestimated by both the Finometer and Finapres (p < 0.01), with percentage median errors of respectively 130% and 103% (Finometer), and 134% and 78% (Finapres). The HF power was substantially unchanged using the Finometer and reduced using the Finapres (-28%, p < 0.05). The limits of agreement between noninvasive and invasive spectral measurements were wide. Linear system analysis showed that most (> 80%) of the power of noninvasive signals was linearly related to the power of the invasive signal. The characteristic frequency of each band was substantially preserved in both noninvasive signals. The results for diastolic pressure were similar, but the Finapres errors in the VLF and LF bands were lower. Baroreflex sensitivity was significantly underestimated by both devices (Finometer: -31 %, Finapres: -24%). Despite previous studies having shown that brachial artery waveforrn reconstruction performed by the Finometer has improved the accuracy of blood pressure measurement compared to the Finapres device, measurement of blood pressure variability in cardiac disease patients provides worse results in most spectral parameters and a better accuracy only in the HF band of systolic pressure.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [21] A CENTURY OF NONINVASIVE ARTERIAL-PRESSURE MEASUREMENT - FROM MAREY TO PENAZ AND FINAPRES
    WESSELING, KH
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (2-3): : 50 - 65
  • [22] Device for the self-measurement of blood pressure that can monitor blood pressure during sleep
    Chonan, K
    Kikuya, M
    Araki, T
    Fujiwara, T
    Suzuki, M
    Michimata, M
    Hashimoto, J
    Ohkubo, T
    Hozawa, A
    Yamamoto, N
    Miyawaki, Y
    Matsubara, M
    Imai, Y
    BLOOD PRESSURE MONITORING, 2001, 6 (04) : 203 - 205
  • [23] Accuracy of a wrist blood pressure monitor:: Comparison with intra-arterial pressure
    Sanchez, FJ
    Morillas, P
    Bertomeu, V
    Ruiz, JM
    Frutos, A
    Carrillo, P
    Nuñez, D
    Quiles, J
    Valero, R
    Rodriguez, JA
    JOURNAL OF HYPERTENSION, 2005, 23 : S35 - S35
  • [24] ACCURACY OF BLOOD-PRESSURE MEASUREMENT BY THE DINAMAP MONITOR IN INFANTS AND CHILDREN
    PARK, MK
    MENARD, SM
    PEDIATRICS, 1987, 79 (06) : 907 - 914
  • [25] ACCURACY OF BLOOD-PRESSURE MEASUREMENT BY THE DINAMAP MONITOR IN INFANTS AND CHILDREN
    PARK, MK
    MENARD, SW
    CLINICAL RESEARCH, 1987, 35 (01): : A51 - A51
  • [26] Measurement of Heart Rate Variability Using an Oscillometric Blood Pressure Monitor
    Ahmad, Saif
    Bolic, Miodrag
    Dajani, Hilmi
    Groza, Voicu
    Batkin, Izmail
    Rajan, Sreeraman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (10) : 2575 - 2590
  • [27] A ring-type device for the noninvasive measurement of arterial blood pressure
    Zheng, DC
    Zhang, YT
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3184 - 3187
  • [28] Noninvasive Continuous Blood Pressure Measurement with Wearable Millimeter Wave Device
    Liao, Catherine
    Shay, Oliver
    Gomes, Elizabeth
    Bikhchandani, Nikhil
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2021,
  • [29] THE FINAPRES 2300E FINGER CUFF - THE INFLUENCE OF CUFF APPLICATION ON THE ACCURACY OF BLOOD-PRESSURE MEASUREMENT
    JONES, RDM
    KORNBERG, JP
    ROULSON, CJ
    VISRAM, AR
    IRWIN, MG
    ANAESTHESIA, 1993, 48 (07) : 611 - 615
  • [30] ACCURACY OF BEAT-TO-BEAT NONINVASIVE MEASUREMENT OF FINGER ARTERIAL-PRESSURE USING THE FINAPRES - A SPECTRAL-ANALYSIS APPROACH
    NOVAK, V
    NOVAK, P
    SCHONDORF, R
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (02): : 118 - 126