Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device

被引:33
|
作者
Maestri, R [1 ]
Pinna, GD
Robbi, E
Capomolla, S
La Rovere, MT
机构
[1] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Biomed Engn, I-27040 Montescano, PV, Italy
[2] IRCCS, Sci Inst Montescano, S Maugeri Fdn, Dept Cardiol, I-27040 Montescano, PV, Italy
关键词
blood pressure variability; noninvasive baroreflex sensitivity;
D O I
10.1088/0967-3334/26/6/021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To assess the accuracy of spectral indices of arterial pressure variability and baroreflex sensitivity obtained from beat-by-beat noninvasive blood pressure recordings by the Finometer device, we compared these measures with those obtained from intra-arterial recordings. The performance of the Finometer was also compared to the traditional Finapres device. In 19 cardiac disease patients, including myocardial infarction, heart failure and cardiac transplant, we estimated the power of systolic and diastolic pressures in the VLF (0.010.04 Hz), LF (0.04-0.L5 Hz) and HF (0.15-0.45 Hz) bands and computed absolute and percentage errors relative to intra-arterial brachial pressure. We also computed the characteristic frequency of each band (i.e. the barycentric frequency of spectral components identified in the band). The variability of systolic pressure in the VLF and LF bands was markedly overestimated by both the Finometer and Finapres (p < 0.01), with percentage median errors of respectively 130% and 103% (Finometer), and 134% and 78% (Finapres). The HF power was substantially unchanged using the Finometer and reduced using the Finapres (-28%, p < 0.05). The limits of agreement between noninvasive and invasive spectral measurements were wide. Linear system analysis showed that most (> 80%) of the power of noninvasive signals was linearly related to the power of the invasive signal. The characteristic frequency of each band was substantially preserved in both noninvasive signals. The results for diastolic pressure were similar, but the Finapres errors in the VLF and LF bands were lower. Baroreflex sensitivity was significantly underestimated by both devices (Finometer: -31 %, Finapres: -24%). Despite previous studies having shown that brachial artery waveforrn reconstruction performed by the Finometer has improved the accuracy of blood pressure measurement compared to the Finapres device, measurement of blood pressure variability in cardiac disease patients provides worse results in most spectral parameters and a better accuracy only in the HF band of systolic pressure.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [1] FINAPRES - A NONINVASIVE DEVICE TO MONITOR BLOOD-PRESSURE
    PORTER, KB
    OBRIEN, WF
    KIEFERT, V
    KNUPPEL, RA
    OBSTETRICS AND GYNECOLOGY, 1991, 78 (03): : 430 - 433
  • [2] Spectral analysis of arterial blood pressure variability: Assessing the accuracy of the finometer device
    Maestri, R
    Pinna, GD
    Gobbi, E
    Robbi, E
    La Rovere, M
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 505 - 508
  • [3] Validation of the Finometer device for measurement of blood pressure in black women
    Schutte, AE
    Huisman, HW
    van Rooyen, JM
    Malan, NT
    Schutte, R
    JOURNAL OF HUMAN HYPERTENSION, 2004, 18 (02) : 79 - 84
  • [4] Validation of the Finometer device for measurement of blood pressure in black women
    A E Schutte
    H W Huisman
    J M van Rooyen
    N T Malan
    R Schutte
    Journal of Human Hypertension, 2004, 18 : 79 - 84
  • [5] The SOMNOtouch device as a novel method for measuring short-term blood pressure variability: a comparison with the Finometer
    Manning, Lisa S.
    Robinson, Thompson G.
    Panerai, Ronney B.
    BLOOD PRESSURE MONITORING, 2015, 20 (06) : 361 - 368
  • [6] COMPARISON OF INVASIVE AND NONINVASIVE MEASUREMENT OF CONTINUOUS ARTERIAL-PRESSURE USING THE FINAPRES
    STOKES, DN
    CLUTTONBROCK, T
    PATIL, C
    THOMPSON, JM
    HUTTON, P
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (01) : 26 - 35
  • [7] Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in the prone position
    Dewhirst, Elisabeth
    Corridore, Marco
    Klamar, Jan
    Beebe, Allan
    Rice, Julie
    Barry, N'Diris
    Tobias, Joseph D.
    JOURNAL OF CLINICAL ANESTHESIA, 2013, 25 (04) : 309 - 313
  • [8] MORBIDITY AFTER USE OF THE FINAPRES BLOOD-PRESSURE MONITOR
    NORTHWOOD, D
    ANAESTHESIA, 1989, 44 (12) : 1010 - 1011
  • [9] Accuracy improvement of noninvasive finger blood pressure measurement
    Lackovic, I
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 281 - 284
  • [10] NONINVASIVE MEASUREMENT OF SYSTEMIC ARTERIAL-PRESSURE BY FINAPRES IN ANESTHETIZED DOGS
    TABARU, H
    WATANABE, H
    TANAKA, M
    NAKAMA, S
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1990, 52 (02): : 427 - 430