Recent Tests of X-ray Spectrometers using Polycapillary optics

被引:4
|
作者
Heald, Steve [1 ]
Seidler, Gerald T. [2 ]
Mortensen, Devon [2 ]
Mattern, Brian [2 ]
Bradley, Joseph A. [3 ]
Hess, Nancy [4 ]
Bowden, Mark [4 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[2] Univ Washington, Dept Phys, Seattle, WA 98195 USA
[3] Lawrence Livermore Natl Lab, Livermore, CA USA
[4] Pacific Northwest Natl Lab, Richland, WA USA
基金
加拿大自然科学与工程研究理事会;
关键词
Polycapillary; X-ray Spectroscopy; X-ray spectrometers; XAS; ELECTRONIC EXCITATIONS; CAPILLARY OPTICS; HIGH-PRESSURE; WAFERS;
D O I
10.1117/12.929960
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Polycapillary optics provide a promising approach for coupling highly-divergent x-ray emission or inelastic scattering to high-resolution crystal analyzers. We present recent results looking at the application of polycapillary collimators to emission spectrometers. The first application uses a collimating optic and a flat crystal to provide a tunable x-ray fluorescence detector. At high-flux synchrotron radiation sources there is sufficient flux (similar to 10(13) ph/sec) to allow application of X-ray Absorption Spectroscopy (XAS) to ppb concentrations if the fluorescence signal can be isolated from an intense background. The polycapillary based analyzer easily achieves the >10(6) background reduction needed for such measurements. It has the additional advantage of being confocal, only collecting the signal from a small volume at the optic focus, effectively eliminating background from sample substrates, windows, or air scattering. Second, the same type of analyzer can be used for higher-resolution emission spectroscopy if operated close to 90 degrees Bragg angle, and we report results of the commissioning of a user-available instrument suitable for few-eV resolution emission spectroscopy, including the demonstration of roughly order-of-magnitude improved measurement times compared to use of a traditional, single spherically-bent crystal analyzer. As part of this effort, we have developed a process for enhancing the integral reflectivity of Si analyzer crystals through plastic deformation at high temperatures.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Measurement of X-Ray and Neutron Sources with Polycapillary Optics
    Kumakhov, A. A.
    Dmitriev, I. V.
    TECHNICAL PHYSICS, 2011, 56 (06) : 831 - 833
  • [22] Technologies of manufacturing polycapillary optics for x-ray engineering
    Beloglazov, V. I.
    Langhoff, N.
    Tuchin, V. V.
    Bjeoumikhov, A.
    Bjeoumikhova, Z.
    Wedel, R.
    Skibina, N. B.
    Skibina, Yu. S.
    Chainikov, M. V.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2005, 13 (04) : 179 - 183
  • [23] Development of polycapillary X-ray optics for synchrotron spectroscopy
    Popecki, Mark A.
    Bennis, Daniel
    Adams, Bernhard
    O'Mahony, Aileen
    Craven, Christopher A.
    Foley, Michael R.
    Minot, Michael J.
    Renaud, Joseph M.
    Bond, Justin L.
    Stochaj, Michael E.
    Attenkofer, Klaus
    Stavitski, Eli
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS X, 2015, 9588
  • [24] Polycapillary optics for soft X-ray imaging and tomography
    Pacella, D.
    Dabagov, S.
    Murtas, F.
    Romano, A.
    Hampai, D.
    Gabellieri, L.
    Mazon, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2011, 34 (04): : 513 - 520
  • [25] Fine structures of divergence of polycapillary X-ray optics
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Lin, Xiaoyan
    Luo, Ping
    Pan, Qiuli
    Ding, Xunliang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (23): : 2758 - 2761
  • [26] X-RAY OPTICS - POLYCAPILLARY OPTICS COLLIMATE AND FOCUS X-RAYS
    LEWOTSKY, K
    LASER FOCUS WORLD, 1994, 30 (09): : 30 - 32
  • [27] Application of polycapillary optics to hard x-ray astronomy
    Russell, CH
    Gibson, W
    Gubarev, M
    Hofmann, FA
    Joy, M
    MacDonald, CA
    Wang, L
    Xiao, QF
    Youngman, R
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 369 - 377
  • [28] Measurement of X-ray and neutron sources with polycapillary optics
    A. A. Kumakhov
    I. V. Dmitriev
    Technical Physics, 2011, 56 : 831 - 833
  • [29] Property of slice square polycapillary x-ray optics
    Peng, Shi-Qi
    Liu, Zhi-Guo
    Sun, Tian-Xi
    Wang, Kai
    Yi, Long-Tao
    Yang, Kui
    Chen, Man
    Wang, Jin-Bang
    CHINESE PHYSICS B, 2016, 25 (02)
  • [30] POLYCAPILLARY X-RAY OPTICS FOR MACROMOLECULAR CRYSTALLOGRAPHY.
    Owens, S. M.
    Ullrich, J. B.
    Ponomarev, I. Yu.
    Xiao, Q. -F.
    Carter, D.
    Sisk, R. C.
    Gibson, W. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C494 - C494