Comparison of Passive 2-D and 3-D Ring Arrays for Medical Telemetry Focusing

被引:4
|
作者
Bernety, Hossein Mehrpour [1 ]
Puckett, Richard D. [1 ]
Schurig, David [1 ]
Furse, Cynthia [1 ]
机构
[1] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
来源
关键词
Focusing; implantable medical devices (IMDs); loop antennas; subdermal antennas; wireless power transfer (WPT); WIRELESS POWER DELIVERY; SAFETY CONSIDERATIONS; HUMAN-BODY; ANTENNA; DESIGN; OPTIMIZATION; BIOTELEMETRY; IMPLANTS; LINK;
D O I
10.1109/LAWP.2019.2911928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this letter, we investigate the performance of subdermal ring designs for focusing electromagnetic fields inside the body for next-generation implantablemedical devices. We will concentrate on the Medical Implant Communications Service band (402-405 MHz), but prepare our design at 433 MHz, the nearest Industrial, Scientific, Medical band. The designs include two-dimensional (2-D or coplanar) and 3-D arrays of circular rings and 3-D arrays of ellipses. The 3-D ring and ellipse arrays focus the fields more effectively than 2-D designs, through constructive coupling between the rings. Compared to the case where no rings are used, the power available from the focused field 20 mm below the skin is 2.24 times and 3.12 times larger if 3-D rings and 3-D ellipses are utilized, respectively. Rings can be used for circular polarization applications, and ellipses are more optimal for linear polarization applications.
引用
收藏
页码:1189 / 1193
页数:5
相关论文
共 50 条
  • [11] Finite element simulation and modeling of 2-D arrays for 3-D ultrasonic imaging
    McKeighen, R
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (05) : 1395 - 1405
  • [12] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093
  • [13] Sparse 2-D Arrays for 3-D phased array imaging - Design methods
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1073 - 1086
  • [14] Flexible Multielectrode Arrays With 2-D and 3-D Contacts for In Vivo Electromyography Recording
    Zia, Muneeb
    Chung, Bryce
    Sober, Samuel
    Bakir, Muhannad S.
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2020, 10 (02): : 197 - 202
  • [15] Quantum critical points in 2-D and 3-D arrays of ultrasmall Josephson junctions
    José, JV
    Kopec, TK
    CONDENSED MATTER THEORIES, VOL 16, 2001, 16 : 151 - 160
  • [16] Seeing and understanding 3-d medical images through 2-d renditions
    Toennies, KD
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1279 - 1284
  • [17] Pattern- and amplitude-optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing
    Weber, PK
    Schmitt, RM
    ACOUSTICAL IMAGING, VOL 22, 1996, 22 : 439 - 444
  • [18] VORTICES IN 2-D AND 3-D SUPERFLUIDS
    BOWLEY, RM
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1992, 87 (3-4) : 137 - 196
  • [19] 2-D approaches to a 3-D problem
    Lamb, RG
    HYDROCARBON PROCESSING, 1998, 77 (04): : 175 - 175
  • [20] Polyelectrolytes of 2-D and 3-D polyphenylenes
    Mihov, G
    Bauer, RE
    Tchebotareva, N
    Knoll, W
    Schmidt, M
    Thünemann, AF
    Müllen, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U476 - U476