Comparison of Passive 2-D and 3-D Ring Arrays for Medical Telemetry Focusing

被引:4
|
作者
Bernety, Hossein Mehrpour [1 ]
Puckett, Richard D. [1 ]
Schurig, David [1 ]
Furse, Cynthia [1 ]
机构
[1] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
来源
关键词
Focusing; implantable medical devices (IMDs); loop antennas; subdermal antennas; wireless power transfer (WPT); WIRELESS POWER DELIVERY; SAFETY CONSIDERATIONS; HUMAN-BODY; ANTENNA; DESIGN; OPTIMIZATION; BIOTELEMETRY; IMPLANTS; LINK;
D O I
10.1109/LAWP.2019.2911928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this letter, we investigate the performance of subdermal ring designs for focusing electromagnetic fields inside the body for next-generation implantablemedical devices. We will concentrate on the Medical Implant Communications Service band (402-405 MHz), but prepare our design at 433 MHz, the nearest Industrial, Scientific, Medical band. The designs include two-dimensional (2-D or coplanar) and 3-D arrays of circular rings and 3-D arrays of ellipses. The 3-D ring and ellipse arrays focus the fields more effectively than 2-D designs, through constructive coupling between the rings. Compared to the case where no rings are used, the power available from the focused field 20 mm below the skin is 2.24 times and 3.12 times larger if 3-D rings and 3-D ellipses are utilized, respectively. Rings can be used for circular polarization applications, and ellipses are more optimal for linear polarization applications.
引用
收藏
页码:1189 / 1193
页数:5
相关论文
共 50 条
  • [1] 3-D/2-D registration by integrating 2-D information in 3-D
    Tomazevic, D
    Likar, B
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) : 17 - 27
  • [2] Temperature Effects in NAND Flash Memories: A Comparison Between 2-D and 3-D Arrays
    Resnati, Davide
    Goda, Akira
    Nicosia, Gianluca
    Miccoli, Carmine
    Spinelli, Alessandro S.
    Compagnoni, Christian Monzio
    IEEE ELECTRON DEVICE LETTERS, 2017, 38 (04) : 461 - 464
  • [3] Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] 2-D to 3-D conversion: The future of medical imaging
    Bendelstein, Harold L.
    ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (12) : 450 - 451
  • [5] MORPHING IN 2-D AND 3-D
    HALL, V
    DR DOBBS JOURNAL, 1993, 18 (07): : 18 - 20
  • [6] Accumulating, directing and focusing properties of 2-D and 3-D objects of biisotropic materials
    Bogdanov, FG
    Karkashadze, DD
    PROCEEDINGS OF III INTERNATIONAL SEMINAR/WORKSHOP ON DIRECT AND INVERSE PROBLEMS OF ELECTROMAGNETIC AND ACOUSTIC WAVE THEORY, 1998, : 93 - 96
  • [7] COMPARISON OF 2-D AND 3-D DYNAMIC ANALYSES OF EARTH DAMS
    MEJIA, LH
    SEED, HB
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1983, 109 (11): : 1383 - 1398
  • [8] Comparison Between 2-D and 3-D Electromagnetic Modeling of Railgun
    Shvetsov, Gennady A.
    Stankevich, Sergey V.
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (01) : 453 - 457
  • [9] A Galerkin method for the simulation of the transient 2-D/2-D and 3-D/3-D linear Boltzmann equation
    Gobbert, Matthias K.
    Webster, Samuel G.
    Cale, Timothy S.
    JOURNAL OF SCIENTIFIC COMPUTING, 2007, 30 (02) : 237 - 273
  • [10] A Galerkin Method for the Simulation of the Transient 2-D/2-D and 3-D/3-D Linear Boltzmann Equation
    Matthias K. Gobbert
    Samuel G. Webster
    Timothy S. Cale
    Journal of Scientific Computing, 2007, 30 : 237 - 273