Experimental investigation of adjacent buildings connected by fluid damper

被引:0
|
作者
Xu, YL [1 ]
Zhan, S [1 ]
Ko, JM [1 ]
Zhang, WS [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Peoples R China
来源
关键词
experimental investigation; adjacent buildings; fluid damper; dynamic characteristic; harmonic response;
D O I
10.1002/(SICI)1096-9845(199906)28:6<609::AID-EQE831>3.0.CO;2-S
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dynamic characteristic and harmonic response of adjacent buildings connected by fluid damper were experimentally investigated using model buildings and fluid damper. Two building models were constructed as two three-storey shear buildings of different natural frequencies. Model fluid damper connecting the two buildings was designed as linear viscous damper of which damping coefficient could be adjusted. The two buildings without fluid dampers connected were first tested to obtain their individual dynamic characteristics and responses to harmonic excitation, The tests were then carried out to determine modal damping ratios of the adjacent buildings connected by the fluid damper of different damping coefficients and at different locations. Optimal damper damping coefficient and location for achieving the maximum modal damping ratio were thus found. The measured modal damping ratios and harmonic responses of the building-fluid damper system were finally compared with those from the individual buildings. The comparison showed that the fluid damper of proper parameter could significantly increase the modal damping ratio and tremendously reduce the dynamic response of both buildings. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:609 / 631
页数:23
相关论文
共 50 条
  • [41] Experimental investigation into the effect of magnetorheological fluid damper on vibration and chatter in straight turning process
    Emami, Mohsen
    Nasab, Vahid Hasan
    Akar, Samet
    Batako, Andre
    JOURNAL OF MANUFACTURING PROCESSES, 2023, 99 : 825 - 847
  • [42] AN EXPERIMENTAL INVESTIGATION OF ELECTRORHEOLOGICAL FLUID DAMPER RECOIL SYSTEM USED IN HEAVY DUTY APPLICATION
    Patil, Santosh R.
    Krishna, S.
    Gawade, S. S.
    Desavale, R. G.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 4, 2020,
  • [43] Experimental investigation on the interaction between magneto-rheological fluid damper and stay cable
    Liu, Min
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2013, 2013, 8692
  • [44] Experimental Investigation of a Nonlinear Damper System
    Lu Zheng
    2013 25TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2013, : 1392 - 1397
  • [45] Modelling and experimental investigation of an active damper
    Teixeira, Rafael Luis
    Lepore Neto, Francisco Paulo
    Ribeiro, Jose Francisco
    SHOCK AND VIBRATION, 2006, 13 (4-5) : 343 - 354
  • [46] Performance of Linear and Nonlinear damper connected buildings under blast and seismic excitations
    Kangda, Muhammed Zain
    Bakre, Sachin
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2021, 6 (02)
  • [47] Performance of Linear and Nonlinear damper connected buildings under blast and seismic excitations
    Muhammed Zain Kangda
    Sachin Bakre
    Innovative Infrastructure Solutions, 2021, 6
  • [48] Evaluation of seismic performance of connected adjacent buildings using fragility curves
    Yarali, Mohammadhossein
    Fathi, Farshid
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 176
  • [49] Dynamic behavior of adjacent buildings connected by linear viscous/viscoelastic dampers
    Tubaldi, E.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (08): : 1086 - 1102
  • [50] Seismic performance assessment of adjacent building structures connected with superelastic shape memory alloy damper and comparison with yield damper
    Gur, Sourav
    Roy, Koushik
    Singh, Pranay
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (05):