Experimental investigation of adjacent buildings connected by fluid damper

被引:0
|
作者
Xu, YL [1 ]
Zhan, S [1 ]
Ko, JM [1 ]
Zhang, WS [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Peoples R China
来源
关键词
experimental investigation; adjacent buildings; fluid damper; dynamic characteristic; harmonic response;
D O I
10.1002/(SICI)1096-9845(199906)28:6<609::AID-EQE831>3.0.CO;2-S
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dynamic characteristic and harmonic response of adjacent buildings connected by fluid damper were experimentally investigated using model buildings and fluid damper. Two building models were constructed as two three-storey shear buildings of different natural frequencies. Model fluid damper connecting the two buildings was designed as linear viscous damper of which damping coefficient could be adjusted. The two buildings without fluid dampers connected were first tested to obtain their individual dynamic characteristics and responses to harmonic excitation, The tests were then carried out to determine modal damping ratios of the adjacent buildings connected by the fluid damper of different damping coefficients and at different locations. Optimal damper damping coefficient and location for achieving the maximum modal damping ratio were thus found. The measured modal damping ratios and harmonic responses of the building-fluid damper system were finally compared with those from the individual buildings. The comparison showed that the fluid damper of proper parameter could significantly increase the modal damping ratio and tremendously reduce the dynamic response of both buildings. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:609 / 631
页数:23
相关论文
共 50 条
  • [21] Optimization of Tuned Mass Damper for Adjacent Buildings with Equal Properties
    Bekdas, Gebrail
    Nigdeli, Sinan Melih
    11TH INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2013, PTS 1 AND 2 (ICNAAM 2013), 2013, 1558 : 429 - 432
  • [22] Control of Adjacent Buildings Using Shared Tuned Mass Damper
    Guenidi, Z.
    Abdeddaim, M.
    Ounis, A.
    Shrimali, M. K.
    Datta, T. K.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1568 - 1573
  • [23] Random response analysis of adjacent structures connected with friction damper
    Patel C.C.
    Asian Journal of Civil Engineering, 2021, 22 (6) : 1115 - 1129
  • [24] Seismic Response Control for Multiple Buildings Connected with MR Damper
    Seto, Kazuto
    Tanaka, Takashi
    ADVANCES IN VIBRATION ENGINEERING, 2008, 7 (01): : 41 - 49
  • [25] Seismic Response of Adjacent Buildings Connected with Friction Dampers
    A. V. Bhaskararao
    R. S. Jangid
    Bulletin of Earthquake Engineering, 2006, 4 : 43 - 64
  • [26] Seismic response of adjacent buildings connected with friction dampers
    Bhaskararao, A. V.
    Jangid, R. S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2006, 4 (01) : 43 - 64
  • [27] Pole Allocation Applied to Two Buildings Connected by Joint Damper
    Ikeda, Yoshiki
    Matsumoto, Yuki
    SHOCK AND VIBRATION, 2024, 2024
  • [28] Vibration control of adjacent buildings based on tuned viscous mass damper
    Kang, Xiaofang
    Li, Shuai
    Hu, Jun
    Xia, Guanghui
    Cai, Yi
    Zheng, Jun
    Luo, Jiaxin
    Liu, Guoliang
    Lei, Shancheng
    Wang, Xinqi
    Huang, Qiwen
    Han, Mengjun
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING AND COMPUTATIONAL MECHANICS, 2023, 176 (02) : 65 - 83
  • [29] Experimental Investigation on Boring Tool Vibration Control Using MR Fluid Damper
    Mohan, E.
    Natarajan, U.
    JOURNAL OF ADVANCED MANUFACTURING SYSTEMS, 2016, 15 (01) : 13 - 25
  • [30] Seismic response of adjacent buildings connected by active tendon devices
    Zhang, WS
    Xu, YL
    SMART STRUCTURES AND MATERIALS 1999: SMART SYSTEMS FOR BRIDGES, STRUCTURES AND HIGHWAYS, 1999, 3671 : 217 - +