Development of an amperometric enzyme biosensor for the determination of the antioxidant tert-butylhydroxyanisole in a medium of reversed micelles

被引:13
|
作者
Ruiz, MA
Reviejo, AJ
Parrado, C
Pingarron, JM
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
[2] UNIV SAN PUEBLO,CTR CIENCIAS EXPT & TECN,AREA QUIM ANALIT,E-28668 MADRID,SPAIN
关键词
tyrosinase electrode; reversed micelles; flow injection; phenolic antioxidants;
D O I
10.1002/elan.1140080606
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biocatalytic scheme, based on the enzyme tyrosinase, has been developed for the determination of the antioxidant tert-butylhydroxyanisole (BHA) in food samples. Reversed micelles formed with ethyl acetate as organic solvent, dioctyl sulfosuccinate (AOT) as emulsifying agent, and phosphate buffer of pH 7.4 as aqueous phase, has been employed as the working medium. The potential applied to the tyrosinase electrode, as well as the temperature of the working reversed micelle, the percentage of aqueous phase, and the pH of the phosphate buffer solution have been optimized. The stability of the enzyme electrode with time has been also evaluated. A very good selectivity has been found with respect to potential interference from other substances commonly present in commercial antioxidant mixtures in food. An Eastman-AQ/enzyme immobilization approach has been employed to improve the stability of the tyrosinase biosensor in reversed micelles flowing streams. A how injection method with amperometric detection for the determination of BHA has been developed and applied to the analysis of this antioxidant in commercial biscuits.
引用
收藏
页码:529 / 533
页数:5
相关论文
共 50 条
  • [2] DETERMINATION OF TERT-BUTYLHYDROXYANISOLE AND TERT-BUTYLHYDROXYTOLUENE BY FLOW-INJECTION WITH AMPEROMETRIC DETECTION
    YANEZSEDENO, P
    PINGARRON, JM
    DIEZ, LMP
    ANALYTICA CHIMICA ACTA, 1991, 252 (1-2) : 153 - 159
  • [3] VOLTAMMETRIC DETERMINATION OF TERT-BUTYLHYDROXYANISOLE IN MICELLAR AND EMULSIFIED MEDIA
    GONZALEZ, A
    RUIZ, MA
    YANEZSEDENO, P
    PINGARRON, JM
    ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) : 63 - 71
  • [4] DEVELOPMENT OF AN AMPEROMETRIC BIOSENSOR FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS IN REVERSED MICELLES
    LIU, F
    REVIEJO, AJ
    PINGARRON, JM
    TALANTA, 1994, 41 (03) : 455 - 459
  • [5] Development of amperometric enzyme electrodes in reversed micelles media
    Pingarron, JM
    JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1996, 93 (04) : 793 - 803
  • [6] CATALYTIC-VOLTAMMETRIC DETERMINATION OF THE ANTIOXIDANT TERT-BUTYLHYDROXYANISOLE (BHA) AT A NICKEL PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    RUIZ, MA
    CALVO, MP
    PINGARRON, JM
    TALANTA, 1994, 41 (02) : 289 - 294
  • [7] A New Nanostructure Square Wave Voltammetric Platform for Determination of Tert-butylhydroxyanisole in Food Samples
    Karimi, Fatemeh
    Bijad, Majede
    Farsi, Mohammad
    Vahid, Amir
    Asari-Bami, Hesam
    Wen, Yangping
    Ganjali, Mohammad Reza
    CURRENT ANALYTICAL CHEMISTRY, 2019, 15 (02) : 172 - 176
  • [8] A nanostructure voltammetric platform amplified with ionic liquid for determination of tert-butylhydroxyanisole in the presence kojic acid
    Zahra Shamsadin-Azad
    Mohammad A. Taher
    Somaye Cheraghi
    Hassan Karimi-Maleh
    Journal of Food Measurement and Characterization, 2019, 13 : 1781 - 1787
  • [9] ADVANCES IN AMPEROMETRIC ENZYME ELECTRODES IN REVERSED MICELLES
    REVIEJO, AJ
    FERNANDEZ, C
    LIU, F
    PINGARRON, JM
    WANG, J
    ANALYTICA CHIMICA ACTA, 1995, 315 (1-2) : 93 - 99
  • [10] A nanostructure voltammetric platform amplified with ionic liquid for determination of tert-butylhydroxyanisole in the presence kojic acid
    Shamsadin-Azad, Zahra
    Taher, Mohammad A.
    Cheraghi, Somaye
    Karimi-Maleh, Hassan
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2019, 13 (03) : 1781 - 1787