Development of an amperometric enzyme biosensor for the determination of the antioxidant tert-butylhydroxyanisole in a medium of reversed micelles

被引:13
|
作者
Ruiz, MA
Reviejo, AJ
Parrado, C
Pingarron, JM
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
[2] UNIV SAN PUEBLO,CTR CIENCIAS EXPT & TECN,AREA QUIM ANALIT,E-28668 MADRID,SPAIN
关键词
tyrosinase electrode; reversed micelles; flow injection; phenolic antioxidants;
D O I
10.1002/elan.1140080606
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biocatalytic scheme, based on the enzyme tyrosinase, has been developed for the determination of the antioxidant tert-butylhydroxyanisole (BHA) in food samples. Reversed micelles formed with ethyl acetate as organic solvent, dioctyl sulfosuccinate (AOT) as emulsifying agent, and phosphate buffer of pH 7.4 as aqueous phase, has been employed as the working medium. The potential applied to the tyrosinase electrode, as well as the temperature of the working reversed micelle, the percentage of aqueous phase, and the pH of the phosphate buffer solution have been optimized. The stability of the enzyme electrode with time has been also evaluated. A very good selectivity has been found with respect to potential interference from other substances commonly present in commercial antioxidant mixtures in food. An Eastman-AQ/enzyme immobilization approach has been employed to improve the stability of the tyrosinase biosensor in reversed micelles flowing streams. A how injection method with amperometric detection for the determination of BHA has been developed and applied to the analysis of this antioxidant in commercial biscuits.
引用
收藏
页码:529 / 533
页数:5
相关论文
共 50 条
  • [31] A New Amperometric Enzyme-based Biosensor for Specific Determination of 17β-estradiol
    Spychalska, K.
    Cabaj, J.
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA' 19), 2019, : 280 - 281
  • [32] Amperometric Enzyme Biosensor for the Determination of High Concentration Lactate in Whole Blood of Athletes
    Chunxiu Liu Zonghui Guo Hui Wang Jianfang Xu Lianshi Feng Xinxia Cai State Key Laboratory of Transducer TechnologyInstitute of ElectronicsChinese Academy of SciencesBeijing China Graduate School of Chinese Academy of SciencesBeijing China Biology CenterChina Institute of Sport ScienceBeijing China
    稀有金属材料与工程, 2006, (S3) : 83 - 86
  • [33] Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents
    Mulchandani, P
    Chen, W
    Mulchandani, A
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (12) : 2562 - 2565
  • [34] Amperometric enzyme biosensor for the determination of high concentration lactate in whole blood of athletes
    Liu, Chunxiu
    Guo, Zonghui
    Wang, Hui
    Xu, Jianfang
    Feng, Lianshi
    Cai, Xinxia
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 83 - 86
  • [35] ELECTROCATALYTIC AND FLOW-INJECTION DETERMINATION OF THE ANTIOXIDANT TERT.-BUTYLHYDROXYANISOLE AT A NICKEL PHTHALOCYANINE POLYMER-MODIFIED ELECTRODE
    RUIZ, MA
    BLAZQUEZ, MG
    PINGARRON, JM
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 49 - 56
  • [36] Development of a sol-gel based amperometric biosensor for the determination of phenolics
    Kane, SA
    Iwuoba, EI
    Smyth, MR
    ANALYST, 1998, 123 (10) : 2001 - 2006
  • [37] Amperometric Enzyme Carbon Paste-Based Biosensor for Quantification of Hydroquinone and Polyphenolic Antioxidant Capacity
    Sys, Milan
    Pekec, Bruna
    Kalcher, Kurt
    Vytras, Karel
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 9030 - 9040
  • [38] Novel approaches to the development of amperometric biosensor for serum cholesterol level determination
    Lo, Yu-Chen
    Ren, Gui
    Honda, Hiroshi
    Hsiao, Meen-Woon
    Wei, Tsao-Yi
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [39] Composite amperometric tyrosinase biosensors for the determination of the additive propyl gallate in a reversed micellar medium
    Morales, MD
    González, MC
    Serra, B
    Reviejo, AJ
    Pingarrón, JM
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (02): : 572 - 579
  • [40] Amperometric bi-enzyme based biosensor for the determination of lactose with an extended linear range
    Loechel, C
    Chemnitius, GC
    Borchardt, M
    Cammann, K
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG A-FOOD RESEARCH AND TECHNOLOGY, 1998, 207 (05): : 381 - 385