ADVANCES IN AMPEROMETRIC ENZYME ELECTRODES IN REVERSED MICELLES

被引:34
|
作者
REVIEJO, AJ
FERNANDEZ, C
LIU, F
PINGARRON, JM
WANG, J
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
[2] NEW MEXICO STATE UNIV,DEPT CHEM,LAS CRUCES,NM 88003
关键词
REVERSED MICELLES; BIOSENSORS; FLOW INJECTION; INHIBITORS;
D O I
10.1016/0003-2670(95)00312-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Some new trends in the development of amperometric enzyme electrodes in reversed micelle systems are shown. The possibility of using these media for on-line applications as well as for enzyme inhibition measurements both in the batch and the now-injection modes is demonstrated. Reversed micelles were formed of ethyl acetate as organic solvent, dioctyl sulfosuccinate as emulsifying agent and a 4% of 0.05 mol l(-1) phosphate buffer of pH 7.4 as aqueous phase. An Eastman AQ/enzyme immobilization approach was used. Flow-injection analysis of various phenolic compounds using the reversed micelle as the carrier solution was accomplished. Despite the hydrodynamic conditions, the immobilized enzyme layer displayed a good stability in the reversed micelle flowing stream. Phenolic compounds with all ortho-positions substituted gave no analytical signal. The possibility of developing reversed micelle enzyme inhibition biosensors is illustrated by monitoring inhibitors of tyrosinase such as benzoic acid, thiourea or propyl gallate, and using phenol as the substrate. The steady-state response towards phenol rapidly decreases upon additions of these compounds at a low concentration level. A reversible inhibition process was shown in all cases, and the type of enzyme inactivation in the reversed micelle of each inhibitor studied. The rapid response of the tyrosinase electrode to the changes of inhibitor concentration in the reversed micelle can be also exploited for on-line applications.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 50 条
  • [1] Development of amperometric enzyme electrodes in reversed micelles media
    Pingarron, JM
    JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1996, 93 (04) : 793 - 803
  • [2] Amperometric biosensors in reversed micelles
    Pingarron, JM
    Reviejo, AJ
    BIOSENSORS FOR DIRECT MONITORING OF ENVIRONMENTAL POLLUTANTS IN FIELD, 1997, 38 : 305 - 316
  • [3] AMPEROMETRIC BIOSENSORS IN REVERSED MICELLES
    REVIEJO, AJ
    LIU, F
    PINGARRON, JM
    WANG, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 374 (1-2): : 133 - 139
  • [4] AMPEROMETRIC ENZYME - ELECTRODES
    MULCHANDANI, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 41 - BTEC
  • [5] AMPEROMETRIC ENZYME ELECTRODES
    LENNOX, B
    ALBERY, WJ
    JOURNAL OF MEDICAL MICROBIOLOGY, 1987, 23 (04) : R8 - R8
  • [6] AMPEROMETRIC ENZYME ELECTRODES
    GREEN, MJ
    HILL, HAO
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1237 - 1243
  • [7] AMPEROMETRIC ENZYME ELECTRODES
    NANJO, M
    GUILBAULT, GG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 75 - 75
  • [8] Amperometric enzyme electrodes
    Calvo, EJ
    Danilowicz, C
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (06) : 563 - 574
  • [9] AMPEROMETRIC ENZYME ELECTRODES
    ALBERY, WJ
    BARTLETT, PN
    CASS, AEG
    EISENTHAL, R
    HIGGINS, IJ
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) : 107 - 119
  • [10] Development of an amperometric enzyme biosensor for the determination of the antioxidant tert-butylhydroxyanisole in a medium of reversed micelles
    Ruiz, MA
    Reviejo, AJ
    Parrado, C
    Pingarron, JM
    ELECTROANALYSIS, 1996, 8 (06) : 529 - 533