Lightning Surge Analysis of a Transmission Line Tower With an XLPE Power Cable and Metallic Cleats Using the FDTD Method

被引:7
|
作者
Tatematsu, Akiyoshi [1 ]
机构
[1] Cent Res Inst Elect Power Ind, Yokosuka, Kanagawa 2400196, Japan
关键词
Poles and towers; Coaxial cables; Finite difference methods; Surges; Wires; Power cables; Lightning; Electromagnetic transient analysis; finite-difference time-domain method (FDTD); lightning; power cables; transmission line (TL) towers; TRANSIENT ELECTROMAGNETIC-FIELDS; AIR-INSULATED SUBSTATION; THIN WIRES; SIMULATION; BOUNDARY;
D O I
10.1109/TEMC.2019.2956931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A direct lightning strike to a transmission line tower may cause overvoltages and insulation failures, and to avoid unexpected insulation failures and protect power equipment, it is necessary to install effective lightning protection measures. To design effective countermeasures, the prediction of lightning surge phenomena is required. The finite-difference time-domain (FDTD) method, one of the full-wave numerical approaches, which do not require the assumption of the transversal electromagnetic mode, has been an effective tool for predicting electromagnetic transient phenomena in 3-D structures, such as transmission line towers. In this article, using a technique for representing coaxial cables in the FDTD method, we simulate a reduced-scale model of a transmission line tower with a power cable, calculate the surge phenomena in the tower model when a surge current is injected into the top of the tower, and compare the FDTD results with the measured results for validation. Furthermore, we propose a technique for simulating the influence of using metallic cleats to fix a power cable to a transmission line tower for FDTD simulations in a 3-D arrangement, and we calculate surge phenomena in practical cross-linked polyethylene power cables placed over a ground plane and installed in a real-scale 77 kV transmission line tower. The FDTD results are validated through the comparison with measured results obtained in a previous study.
引用
收藏
页码:1796 / 1806
页数:11
相关论文
共 50 条
  • [41] Analysis of Lightning Overvoltage Generated in Signal Cable by FDTD Method and Comparison of the Analysis Result with Actual Observed Result
    Ono, Yuto
    Omori, Tatsuya
    Fujita, Hiroyuki
    Arai, Hideki
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [42] Analysis of Extraordinary Optical Transmission With Periodic Metallic Gratings Using ADE-LOD-FDTD Method
    Liang, Tu-Lu
    Shao, Wei
    Shi, Sheng-Bing
    Ou, Haiyan
    IEEE PHOTONICS JOURNAL, 2016, 8 (05):
  • [43] Electromagnetic and Thermal Analysis of a ZnO Element of Transmission-Line Arrester for a Lightning Surge Current
    Saito, Hiroki
    Tanaka, Tokuya
    Tosa, Ryohei
    Baba, Yoshihiro
    Shinjo, Kazuo
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 16 (05) : 813 - 815
  • [44] MODIFIED FOURIER-TRANSFORM LIGHTNING SURGE ANALYSIS OF AN OVERHEAD LINE-UNDERGROUND COAXIAL (CV) CABLE SYSTEM .2. SYSTEM LIGHTNING SURGE RESPONSE
    WAHAB, MAA
    MATSUURA, K
    ELECTRIC POWER SYSTEMS RESEARCH, 1994, 31 (01) : 43 - 49
  • [45] Lightning surge analysis using nonuniform, single-phase line model
    Mamis, MS
    Köksal, M
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (01) : 85 - 90
  • [46] Investigation on Transient Responses of the Transmission Line in a Shelter by Using FDTD Method
    Han, Xiao
    Wang, Jian
    2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 808 - 810
  • [47] TRANSIENT ANALYSIS OF POWER LINE/CABLE SYSTEMS - INCLUDING REACTIVE TERMINATIONS WITH SURGE DIVERTERS
    ANDERSON, JH
    HEATON, AG
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (12): : 2017 - &
  • [48] A distributed modelling method of the transmission tower and transient response analysis of lightning wave process
    Huang, Lin
    Zhou, Lijun
    Wu, Tongshuai
    Hu, Chen
    Zhang, Dong
    Wang, Dongyang
    Chen, Sixiang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (21) : 3017 - 3031
  • [49] Research On On-line Insulation Monitoring And Fault Location Method of Mine Power Supply XLPE Cable
    Wang, Xudong
    Xia, Tao
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [50] Lightning analysis of adjacent grounding systems using multi-conductor transmission line method
    Jamali, Morteza
    Niasati, Mohsen
    Jazaeri, Mostafa
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (10) : 848 - 852