Investigation of Aging Degradation Status of Insulating Elements in Oil-immersed Transformer and its Diagnostic Method Based on Field Measurement Data

被引:56
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Tsuboi, Toshihiro [1 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
Oil-immersed power transformer; aging; insulating oil; breakdown voltage; insulating paper; average polymerization degree (DP); oil components;
D O I
10.1109/TDEI.2013.6451376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To ensure the reliability of oil-immersed power transformers in long-term operation, the influence of aging on various characteristics of their insulating elements must be clarified. The present paper reviewed the degradation status of insulating oil and paper of field-aged transformers, covering investigative results ranging from about 30 years ago to a relatively recent period. The field transformers treated were diverse in terms of their manufacturing year, manufacturer, structure, and voltage class. Despite the examination results of such wide-ranging transformers, there were similar changes in various characteristics due to the aging of insulating oil and paper. For example, as for the insulating oil, due to the aging for about 30 years, the characteristics of the total acid value and volume resistivity had degraded, whereas the breakdown voltage decreased only slightly. Regarding the insulating paper, mechanical characteristics such as the average polymerization degree (DP) were subject to age-related decline, whereas the breakdown voltage did not significantly decrease as with insulating oil. Therefore, based on use of about 30 years, since the life of a transformer is determined by factors such as the degradation of mechanical strength due to thermal stress, insulation degradation is considered less likely to pose a problem at an early stage. Even though it is difficult to directly measure the degree of degradation of insulating paper, this can be indirectly estimated by measuring the CO2 and CO content and furfural content in insulating oil. On the other hand, given the increasing number of transformers remaining in service over 30 years, which had been deemed the expected service life, consideration must be taken to aging degradation of the insulation performance. It emerged that, in order to identify the degree of degradation of these transformers, it was effective to manage the volume resistivity and dielectric loss tangent trends in electrical terms, the interfacial tension trend in physical terms and the total acid value trend in chemical terms. Analysis of the insulating oil components is also considered an effective means of evaluating aging degradation.
引用
收藏
页码:346 / 355
页数:10
相关论文
共 50 条
  • [31] Estimation of Degradation Indices of Oil-Filled Transformer Based on the Color Data of Insulating Oil
    Oshima, Seiichirou
    Nakamura, Hisahide
    Kobayashi, Hiroshi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 16 (06) : 882 - 887
  • [32] Numerical and Experimental Investigation of Temperature Distribution for Oil-Immersed Transformer Winding Based on Dimensionless Least-Squares and Upwind Finite Element Method
    Liu, Gang
    Zheng, Zhi
    Ma, Xun
    Rong, Shichang
    Wu, Weige
    Li, Lin
    IEEE ACCESS, 2019, 7 : 119110 - 119120
  • [33] Simulation of Fluid-Thermal Field in Oil-Immersed Transformer Winding Based on Dimensionless Least-Squares and Upwind Finite Element Method
    Liu, Gang
    Zheng, Zhi
    Yuan, Dongwei
    Li, Lin
    Wu, Weige
    ENERGIES, 2018, 11 (09)
  • [34] Two-dimensional Temperature Field Analysis of Oil-immersed Transformer Based on Non-uniformly Heat Source
    Liu G.
    Jin Y.
    Ma Y.
    Wang L.
    Chi C.
    Li L.
    Jin, Yanjiao (1002474652@qq.com), 1600, Science Press (43): : 3361 - 3370
  • [35] Research on Vibration Characteristic Analysis and Fault Diagnosis Method of Oil-Immersed Transformer Based on Multi-Physics Coupling
    Yuan, Fating
    Yan, Zhiwei
    Zhang, Renjie
    Yang, Yi
    Jian, Shengkai
    Tang, Bo
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (10) : 1621 - 1630
  • [36] RESEARCH ON HOT SPOT TEMPERATURE INVERSION METHOD OF OIL-IMMERSED TRANSFORMER BASED ON MULTI-PHYSICAL FIELD COUPLING OF MAGNETIC-THERMAL-FLUID
    Gu, Lingyun
    Yuan, Fating
    Zhang, Naiyue
    Bai, Xuefeng
    Zhang, Xin
    Gao, Wenpeng
    Wu, Yan
    Bai, Zhixin
    THERMAL SCIENCE, 2025, 29 (1A): : 199 - 213
  • [37] Analysis of Deterioration Characteristics in Oil-immersed Insulation Pressboard with Different Durations of Aging Based on an Image-processing Method
    Wang, Yongqiang
    Fei, Ruoyu
    Feng, Changhui
    Shang, Jing
    BIORESOURCES, 2020, 15 (03) : 6442 - 6456
  • [38] Dynamic Inversion Method of Hot Spot Temperature of Oil-immersed Transformer Based on Combination of Multiphysics Simulation and Neural Network Algorithm
    Ni Z.
    Sheng G.
    Zhang L.
    Wang F.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (06): : 2466 - 2477
  • [39] Non-electric Protection Method for Oil-immersed Transformer Based on Initial Angular Acceleration of Baffle Rotation of Gas Relay
    Wan S.
    Wei J.
    Lü P.
    Jiang D.
    Dou L.
    Ma Z.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (07): : 2498 - 2505
  • [40] Loss-of-Life Analyses Based on Modified Arrhenius and Relative Aging Rate for Non-Thermally Upgraded Paper in Oil-Immersed Transformer
    Saleh, Najiyah
    Azis, Norhafiz
    Jasni, Jasronita
    Kadir, Mohd Zainal Abidin Ab
    Talib, Mohd Aizam
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2024, 32 (02): : 647 - 667