Investigation of Aging Degradation Status of Insulating Elements in Oil-immersed Transformer and its Diagnostic Method Based on Field Measurement Data

被引:56
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Tsuboi, Toshihiro [1 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
Oil-immersed power transformer; aging; insulating oil; breakdown voltage; insulating paper; average polymerization degree (DP); oil components;
D O I
10.1109/TDEI.2013.6451376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To ensure the reliability of oil-immersed power transformers in long-term operation, the influence of aging on various characteristics of their insulating elements must be clarified. The present paper reviewed the degradation status of insulating oil and paper of field-aged transformers, covering investigative results ranging from about 30 years ago to a relatively recent period. The field transformers treated were diverse in terms of their manufacturing year, manufacturer, structure, and voltage class. Despite the examination results of such wide-ranging transformers, there were similar changes in various characteristics due to the aging of insulating oil and paper. For example, as for the insulating oil, due to the aging for about 30 years, the characteristics of the total acid value and volume resistivity had degraded, whereas the breakdown voltage decreased only slightly. Regarding the insulating paper, mechanical characteristics such as the average polymerization degree (DP) were subject to age-related decline, whereas the breakdown voltage did not significantly decrease as with insulating oil. Therefore, based on use of about 30 years, since the life of a transformer is determined by factors such as the degradation of mechanical strength due to thermal stress, insulation degradation is considered less likely to pose a problem at an early stage. Even though it is difficult to directly measure the degree of degradation of insulating paper, this can be indirectly estimated by measuring the CO2 and CO content and furfural content in insulating oil. On the other hand, given the increasing number of transformers remaining in service over 30 years, which had been deemed the expected service life, consideration must be taken to aging degradation of the insulation performance. It emerged that, in order to identify the degree of degradation of these transformers, it was effective to manage the volume resistivity and dielectric loss tangent trends in electrical terms, the interfacial tension trend in physical terms and the total acid value trend in chemical terms. Analysis of the insulating oil components is also considered an effective means of evaluating aging degradation.
引用
收藏
页码:346 / 355
页数:10
相关论文
共 50 条
  • [21] Research on Oil-immersed Transformer Fault Diagnosis Method Based on Improved Extension Set on Intervals
    Zhou Huayanran
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY (FMSMT 2017), 2017, 130 : 231 - 236
  • [22] Aging evaluation and moisture prediction of oil-immersed cellulose insulation in field transformer using frequency domain spectroscopy and aging kinetics model
    Liu, Jiefeng
    Fan, Xianhao
    Zhang, Yiyi
    Zhang, Chaohai
    Wang, Zixiao
    CELLULOSE, 2020, 27 (12) : 7175 - 7189
  • [23] Aging evaluation and moisture prediction of oil-immersed cellulose insulation in field transformer using frequency domain spectroscopy and aging kinetics model
    Jiefeng Liu
    Xianhao Fan
    Yiyi Zhang
    Chaohai Zhang
    Zixiao Wang
    Cellulose, 2020, 27 : 7175 - 7189
  • [24] Method for Measuring Thermal Flow Field Distribution in Oil-Immersed Transformer Using Dynamic Heat Transfer Coefficient
    Xiao, Jiayi
    Zhang, Zhanlong
    Hao, Yuefeng
    Zhao, Hui
    Liu, Xueli
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [25] Bayesian Optimization-Based Gradient Boosting Method of Fault Detection in Oil-Immersed Transformer and Reactors
    Paul, Devaprasad
    Goswarmi, Arup Kumar
    Chetri, Rahul Lamichane
    Roy, Rajesh
    Sen, Pritin
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 1910 - 1919
  • [26] HST calculation of a 10 kV oil-immersed transformer with 3D coupled-field method
    Ruan, Jiangjun
    Deng, Yongqing
    Huang, Daochun
    Duan, Cihan
    Gong, Ruohan
    Quan, Yu
    Hu, Yuanchao
    Rong, Qingyu
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (05) : 921 - 928
  • [27] A Fault Diagnosis Method of Oil-Immersed Transformer Based on Improved Harris Hawks Optimized Random Forest
    Yi, Lingzhi
    Jiang, Ganlin
    Zhang, Guoyong
    Yu, Wenxin
    Guo, You
    Sun, Tao
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (04) : 2527 - 2540
  • [28] A Fault Diagnosis Method of Oil-Immersed Transformer Based on Improved Harris Hawks Optimized Random Forest
    Lingzhi Yi
    Ganlin Jiang
    Guoyong Zhang
    Wenxin Yu
    You Guo
    Tao Sun
    Journal of Electrical Engineering & Technology, 2022, 17 : 2527 - 2540
  • [29] Temperature Characteristic Analysis and Radiator Optimization of Oil-immersed Transformer Based on Multi-physical Field Simulation
    Yuan F.
    Shi W.
    Wang Y.
    Chen W.
    Tang B.
    Jiang L.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (01): : 221 - 231
  • [30] Simulation of Multi-physical Field of 10 kV Oil-immersed Transformer Based on Adaptive Grid Control
    Deng Y.
    Ruan J.
    Dong X.
    Wu Y.
    Zhang C.
    Chen Q.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (08): : 2924 - 2933