Investigation of Aging Degradation Status of Insulating Elements in Oil-immersed Transformer and its Diagnostic Method Based on Field Measurement Data

被引:56
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Tsuboi, Toshihiro [1 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
Oil-immersed power transformer; aging; insulating oil; breakdown voltage; insulating paper; average polymerization degree (DP); oil components;
D O I
10.1109/TDEI.2013.6451376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To ensure the reliability of oil-immersed power transformers in long-term operation, the influence of aging on various characteristics of their insulating elements must be clarified. The present paper reviewed the degradation status of insulating oil and paper of field-aged transformers, covering investigative results ranging from about 30 years ago to a relatively recent period. The field transformers treated were diverse in terms of their manufacturing year, manufacturer, structure, and voltage class. Despite the examination results of such wide-ranging transformers, there were similar changes in various characteristics due to the aging of insulating oil and paper. For example, as for the insulating oil, due to the aging for about 30 years, the characteristics of the total acid value and volume resistivity had degraded, whereas the breakdown voltage decreased only slightly. Regarding the insulating paper, mechanical characteristics such as the average polymerization degree (DP) were subject to age-related decline, whereas the breakdown voltage did not significantly decrease as with insulating oil. Therefore, based on use of about 30 years, since the life of a transformer is determined by factors such as the degradation of mechanical strength due to thermal stress, insulation degradation is considered less likely to pose a problem at an early stage. Even though it is difficult to directly measure the degree of degradation of insulating paper, this can be indirectly estimated by measuring the CO2 and CO content and furfural content in insulating oil. On the other hand, given the increasing number of transformers remaining in service over 30 years, which had been deemed the expected service life, consideration must be taken to aging degradation of the insulation performance. It emerged that, in order to identify the degree of degradation of these transformers, it was effective to manage the volume resistivity and dielectric loss tangent trends in electrical terms, the interfacial tension trend in physical terms and the total acid value trend in chemical terms. Analysis of the insulating oil components is also considered an effective means of evaluating aging degradation.
引用
收藏
页码:346 / 355
页数:10
相关论文
共 50 条
  • [1] Synthetic diagnostic method for insulation fault of oil-immersed power transformer
    Qian, Z
    Yang, MZ
    Yan, Z
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 872 - 875
  • [2] The Method for Aging Condition Prediction of Transformer Oil-immersed Cellulose Insulation Based upon the Aging Kinetic Equation
    Ren, Guang-wei
    Cheng, Jie
    Zhou, Qing
    Li, Chu-yang
    Wu, Wen-liang
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (EEE 2019), 2019, 185 : 147 - 151
  • [3] Investigation on Heating Aging Mechanism of Cellulose Paper for Oil-Immersed Transformer Main Insulation
    Liu, Daosheng
    Deng, Christopher Garang
    Xu, Xiangdong
    Jing, Ye
    Li, Xiaofan
    Noubissi, Romaric Kammeugue
    Li, Xiaolong
    2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
  • [4] Fault Diagnosis for Oil-immersed Transformer Based on Missing Data Imputation
    Liao, Caibo
    Yang, Jinxin
    Qiu, Zhibin
    Hu, Xiong
    Jiang, Zihao
    Li, Xin
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (09): : 4091 - 4100
  • [5] Fault Detection Method of Oil-immersed Transformer Based on Thermal Imaging
    Song, Xi
    Zhang, Mingdong
    Xie, Weidong
    Cao, Shaorong
    Gao, Chaochao
    Journal of Computers (Taiwan), 2024, 35 (05) : 35 - 46
  • [6] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen, Ming
    Hu, Shuilian
    Mo, Zhenhua
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 72 - 76
  • [7] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen Ming
    Hu Shui-lian
    Mo Zhen-hua
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 313 - 317
  • [8] A Method for Monitoring Operation Status of Oil-immersed Transformer Based on the Baffle Angle Characteristic of Gas Relay
    Wan S.
    Wei J.
    Lü P.
    Jiang D.
    Dou L.
    Ma Z.
    Dianwang Jishu/Power System Technology, 2021, 45 (01): : 417 - 423
  • [9] The whole field temperature rise calculation of oil-immersed power transformer based on thermal network method
    Ai, Mengmeng
    Shan, Yi
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2022, 70 (01) : 55 - 72
  • [10] Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method
    Liu, J.
    Fan, X.
    Zheng, H.
    Zhang, Y.
    Zhang, C.
    Lai, B.
    Wang, J.
    Ren, G.
    Zhang, E.
    CELLULOSE, 2019, 26 (06) : 3891 - 3908