EVALUATION OF METHODS FOR SIZING AND COUNTING OF ULTRASOUND CONTRAST AGENTS

被引:43
|
作者
Sennoga, Charles A. [1 ,2 ,3 ]
Yeh, James S. M. [4 ]
Alter, Julia [1 ]
Stride, Eleanor [5 ]
Nihoyannopoulos, Petros [4 ]
Seddon, John M. [3 ]
Haskard, Dorian O. [4 ]
Hajnal, Joseph V. [1 ]
Tang, Meng-Xing [2 ]
Eckersley, Robert J. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Imaging Sci Dept, London W12 0NN, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London W12 0NN, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Chem, London W12 0NN, England
[4] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London W12 0NN, England
[5] UCL, Dept Mech Engn, London, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 05期
基金
英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
Microbubble number count; Mean size diameter; Size distribution; Electro-impedance volumetric zone sensing; Optical microscopy; Laser diffraction; Intra-method variation; SonoVue (TM); DIAGNOSTIC ULTRASOUND; ALBUMIN MICROBUBBLES; LASER DIFFRACTION; SIZE DISTRIBUTION; DELIVERY; SONOVUE; FUTURE; TISSUE;
D O I
10.1016/j.ultrasmedbio.2012.01.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A precise, accurate and well documented method for the sizing and counting of microbubbles is essential for all aspects of quantitative microbubble-enhanced ultrasound imaging. The efficacy of (a) electro-impedance volumetric zone sensing (ES) also called a Coulter counter/multisizer; (b) optical microscopy (OM); and (c) laser diffraction (LD), for the sizing and counting of microbubbles was assessed. Microspheres with certified mean diameter and number concentration were used to assess sizing and counting reproducibility (precision) and reliability (accuracy) of ES, OM and LD. SonoVue (TM) was repeatedly (n = 3) sized and counted to validate ES, OM and LD sizing and counting efficacy. Statistical analyses of intra-method variability for the SonoVue (TM) mean diameter showed that the best microbubble sizing reproducibility was obtained using OM with a mean diameter sizing variability of 1.1%, compared with a variability of 4.3% for ES and 7.1% for LD. The best microbubble counting reproducibility was obtained using ES with a number concentration variability of 8.3%, compared with a variability of 22.4% forOMand 32% for LD. This study showed that no method is fully suited to both sizing and counting of microbubbles. (E-mail: c.sennoga@imperial.ac.uk) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:834 / 845
页数:12
相关论文
共 50 条
  • [41] Ultrasound Contrast Agents For Ultrasound Molecular Imaging
    Tranquart, F.
    Arditi, M.
    Bettinger, T.
    Frinking, P.
    Hyvelin, J. M.
    Nunn, A.
    Pochon, S.
    Tardy, I.
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2014, 52 (11): : 1268 - 1276
  • [42] Ultrasound Contrast Agents and Ultrasound Molecular Imaging
    Wen, Qiaonong
    Wan, Suiren
    Liu, Zengli
    Xu, Shuang
    Wang, Hairui
    Yang, Biao
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (01) : 190 - 209
  • [43] Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
    Harabis, Vratislav
    Kolar, Radim
    Mezl, Martin
    Jirik, Radovan
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (02) : 151 - 162
  • [44] Microparticle Sizing and Counting Using Light Scattering Methods
    Gabriel, Don A.
    Giordano, Karen
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2010, 36 (08): : 824 - 832
  • [45] SCANNING METHODS IN QUANTITATIVE METALLOGRAPHY (COUNTING SIZING INTEGRATION)
    FISCHMEI.HF
    ACTA POLYTECHNICA SCANDINAVICA-CHEMISTRY INCLUDING METALLURGY SERIES, 1966, (56): : 4 - +
  • [46] Study on contrast effect of microbubbles as ultrasound contrast agents
    Chan, M
    Soetanto, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (5B): : 3078 - 3081
  • [47] Study on contrast effect of microbubbles as ultrasound contrast agents
    Chan, Man
    Soetanto, Kawan
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1998, 37 (5 B): : 3078 - 3081
  • [48] Ultrasound contrast agents - Examples of blood pool agents
    Correas, JM
    Helenon, O
    Pourcelot, L
    Moreau, JF
    ACTA RADIOLOGICA, 1997, 38 : 101 - 112
  • [49] Ultrasound contrast agents - A promising future
    Robbin, ML
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2001, 39 (03) : 399 - +
  • [50] Microbubble spectroscopy of ultrasound contrast agents
    van der Meer, Sander M.
    Dollet, Benjamin
    Voormolen, Marco M.
    Chin, Chien T.
    Bouakaz, Ayache
    de Jong, Nico
    Versluis, Michel
    Lohse, Detlef
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 121 (01): : 648 - 656