EVALUATION OF METHODS FOR SIZING AND COUNTING OF ULTRASOUND CONTRAST AGENTS

被引:43
|
作者
Sennoga, Charles A. [1 ,2 ,3 ]
Yeh, James S. M. [4 ]
Alter, Julia [1 ]
Stride, Eleanor [5 ]
Nihoyannopoulos, Petros [4 ]
Seddon, John M. [3 ]
Haskard, Dorian O. [4 ]
Hajnal, Joseph V. [1 ]
Tang, Meng-Xing [2 ]
Eckersley, Robert J. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Imaging Sci Dept, London W12 0NN, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London W12 0NN, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Chem, London W12 0NN, England
[4] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London W12 0NN, England
[5] UCL, Dept Mech Engn, London, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 05期
基金
英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
Microbubble number count; Mean size diameter; Size distribution; Electro-impedance volumetric zone sensing; Optical microscopy; Laser diffraction; Intra-method variation; SonoVue (TM); DIAGNOSTIC ULTRASOUND; ALBUMIN MICROBUBBLES; LASER DIFFRACTION; SIZE DISTRIBUTION; DELIVERY; SONOVUE; FUTURE; TISSUE;
D O I
10.1016/j.ultrasmedbio.2012.01.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A precise, accurate and well documented method for the sizing and counting of microbubbles is essential for all aspects of quantitative microbubble-enhanced ultrasound imaging. The efficacy of (a) electro-impedance volumetric zone sensing (ES) also called a Coulter counter/multisizer; (b) optical microscopy (OM); and (c) laser diffraction (LD), for the sizing and counting of microbubbles was assessed. Microspheres with certified mean diameter and number concentration were used to assess sizing and counting reproducibility (precision) and reliability (accuracy) of ES, OM and LD. SonoVue (TM) was repeatedly (n = 3) sized and counted to validate ES, OM and LD sizing and counting efficacy. Statistical analyses of intra-method variability for the SonoVue (TM) mean diameter showed that the best microbubble sizing reproducibility was obtained using OM with a mean diameter sizing variability of 1.1%, compared with a variability of 4.3% for ES and 7.1% for LD. The best microbubble counting reproducibility was obtained using ES with a number concentration variability of 8.3%, compared with a variability of 22.4% forOMand 32% for LD. This study showed that no method is fully suited to both sizing and counting of microbubbles. (E-mail: c.sennoga@imperial.ac.uk) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:834 / 845
页数:12
相关论文
共 50 条
  • [21] Ultrasound contrast enhancing agents in neurosonology: principles, methods, future possibilities
    Droste, DW
    Kaps, M
    Navabi, GD
    Ringelstein, EB
    ACTA NEUROLOGICA SCANDINAVICA, 2000, 102 (01): : 1 - 10
  • [22] Methods for producing polymeric drug loaded ultrasound contrast agents.
    Burstein, OM
    Wheatley, MA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U217 - U217
  • [23] In vitro Evaluation of Ultrasound-Assisted Thrombolysis Using Targeted Ultrasound Contrast Agents
    Ruan, Jia-Ling
    Cheng, Po-Wen
    Chen, Suz-Chia
    Chuang, Yueh-Hsun
    Li, Pai-Chi
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1659 - +
  • [24] Evaluation of high frequency ultrasound methods and contrast agents for characterising tumor response to anti-angiogenic treatment
    Rix, Anne
    Lederle, Wiltrud
    Siepmann, Monica
    Fokong, Stanley
    Behrendt, Florian F.
    Bzyl, Jessica
    Grouls, Christoph
    Kiessling, Fabian
    Palmowski, Moritz
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2710 - 2716
  • [25] ULTRASOUND CONTRAST AGENTS - A REVIEW
    GOLDBERG, BB
    LIU, JB
    FORSBERG, F
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (04): : 319 - 333
  • [26] Ultrasound contrast agents: An overview
    Cosgrove, David
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 324 - 330
  • [27] CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND
    OPHIR, J
    PARKER, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04): : 319 - 333
  • [28] Safety of ultrasound contrast agents
    Jarl Å. Jakobsen
    Raymond Oyen
    Henrik S. Thomsen
    Sameh K. Morcos
    European Radiology, 2005, 15 : 941 - 945
  • [29] Improvements in ultrasound contrast agents
    deJong, N
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 72 - 82
  • [30] Ultrasound contrast agents for echocardiography
    Yasu, T
    Schmid-Schönbein, GW
    DRUGS OF TODAY, 2000, 36 (10) : 725 - 731