Heel effect adaptive flat field correction of digital x-ray detectors

被引:7
|
作者
Yu, Yongjian [1 ]
Wang, Jue [2 ]
机构
[1] Varian Med Syst Inc, Xray Prod, Liverpool, NY 13088 USA
[2] Union Coll, Dept Math, Schenectady, NY 12308 USA
关键词
anode heel effect; digital x-ray detector; gain calibration; nonuniformity; source-to-image distance; NONUNIFORMITY;
D O I
10.1118/1.4813303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Anode heel effect renders large-scale background nonuniformities in digital radiographs. Conventional offset/gain calibration is performed at mono source-to-image distance (SID), and disregards the SID-dependent characteristic of heel effect. It results in a residual nonuniform background in the corrected radiographs when the SID settings for calibration and correction differ. In this work, the authors develop a robust and efficient computational method for digital x-ray detector gain correction adapted to SID-variant heel effect, without resorting to physical filters, phantoms, complicated heel effect models, or multiple-SID calibration and interpolation. Methods: The authors present the Duo-SID projection correction method. In our approach, conventional offset/gain calibrations are performed only twice, at the minimum and maximum SIDs of the system in typical clinical use. A fast iterative separation algorithm is devised to extract the detector gain and basis heel patterns from the min/max SID calibrations. The resultant detector gain is independent of SID, while the basis heel patterns are parameterized by the min- and max-SID. The heel pattern at any SID is obtained from the min-SID basis heel pattern via projection imaging principles. The system gain desired at a specific acquisition SID is then constructed using the projected heel pattern and detector gain map. Results: The method was evaluated for flat field and anatomical phantom image corrections. It demonstrated promising improvements over interpolation and conventional gain calibration/correction methods, lowering their correction errors by approximately 70% and 80%, respectively. The separation algorithm was able to extract the detector gain and heel patterns with less than 2% error, and the Duo-SID corrected images showed perceptually appealing uniform background across the detector. Conclusions: The Duo-SID correction method has substantially improved on conventional offset/gain corrections for digital x-ray imaging in an SID-variant environment. The technique is relatively simple, and can be easily incorporated into multiple-point gain calibration/correction techniques. It offers a potentially valuable tool for preprocessing digital x-ray images to boost image quality of mammography, chest and cardiac radiography, as well as automated computer aided diagnostic radiology. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Analytical approximations to the Hotelling trace for digital x-ray detectors
    Clarkson, E
    Pineda, AR
    Barrett, HH
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 339 - 349
  • [42] Digital x-ray imaging using gas microstrip detectors
    Dixit, MS
    Armitage, JC
    Bouius, D
    Diaconescu, L
    Dubeau, J
    Grabari, M
    Johns, PC
    Karlen, D
    Oakham, FG
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1597 - 1601
  • [43] Comparison of different GaAs detectors for X-ray digital radiography
    Bencivelli, W.
    Bertin, R.
    Bertolucci, E.
    Bottigli, U.
    D'Auria, S.
    Del Papa, C.
    Fantacci, M.E.
    Randaccio, P.
    Rosso, V.
    Stefanini, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A338 (2-3) : 549 - 555
  • [44] X-ray detectors: Amorphous silicon offers digital promise
    Graeve, T
    PHOTONICS SPECTRA, 1998, 32 (01) : 115 - 116
  • [45] Two technologies for designing digital X-ray image detectors
    Borisov A.A.
    Veip Yu.A.
    Mazurov A.I.
    Elinson M.B.
    Biomedical Engineering, 2006, 40 (5) : 219 - 222
  • [46] Methods for automatic monitoring of characteristics of digital X-ray detectors
    Berdyakov G.I.
    Zelikman M.I.
    Rtishcheva G.M.
    Biomedical Engineering, 2001, 35 (5) : 238 - 241
  • [47] Electromagnetic pulse protective shielding for digital x-ray detectors
    Schreiner, Stephan
    Rauch, Constantin
    Akstaller, Bernhard
    Bleuel, Paulina
    Froejdh, Eric
    Martynenko, Artem S.
    Mozzanica, Aldo
    Neumayer, Paul
    Wegert, Leonard
    Zielbauer, Bernhard
    Zink, Adrian
    Anton, Gisela
    Michel, Thilo
    Funk, Stefan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (07):
  • [48] Measurement of the noise power spectrum in digital x-ray detectors
    Aufrichtig, R
    Su, Y
    Cheng, Y
    Granfors, PR
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 362 - 372
  • [49] Digital X-ray detectors continue to thrive in medical industry
    Murphy, JP
    PHOTONICS SPECTRA, 2005, 39 (01) : 66 - +
  • [50] Characterization of CMOS pixel detectors for digital X-ray imaging
    Cho, Min Kook
    Kim, Ho Kyung
    Graeve, Thorsten
    Kim, Jung-Min
    ADVANCED NONDESTRUCTUVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1052 - 1055