High-throughput determination of faropenem in human plasma and urine by on-line solid-phase extraction coupled to high-performance liquid chromatography with UV detection and its application to the pharmacokinetic study

被引:15
|
作者
Xie, Rui [1 ,2 ,3 ]
Wen, Jun [1 ,2 ,3 ]
Wei, Hua [1 ,2 ,3 ]
Fan, Guorong [1 ,2 ,3 ]
Zhang, Dabing [4 ]
机构
[1] Second Mil Med Univ, Sch Pharm, Dept Pharmaceut Anal, Shanghai 200433, Peoples R China
[2] Shanghai Key Lab Pharmaceut Metabolite Res, Shanghai 200433, Peoples R China
[3] Shanghai Res Ctr Drug Chinese Mat Med Metab, Shanghai 200433, Peoples R China
[4] Jiangsu Hanbon Sci & Technol Co Ltd, Huaian 223001, Jiangsu, Peoples R China
关键词
Faropenem; Self-made trap column; On-line solid-phase extraction; HPLC; Pharmacokinetic study; IN-VITRO ACTIVITY; QUANTIFICATION;
D O I
10.1016/j.jpba.2009.12.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated system using on-line solid-phase extraction and HPLC with UV detection was developed for the determination of faropenem in human plasma and urine. Analytical process was performed isocratically with two reversed-phase columns connected by a switching valve. After simple pretreatment for plasma and urine with acetonitrile, a volume of 100 mu l upper layer of the plasma or urine samples was injected for on-line SPE column switching HPLC-UV analysis. The analytes were retained on the self-made trap column (Lichrospher C-18, 4.6 mm x 37 mm, 25 mu m) with the loading solvent (20 mM NaH2PO4 adjusted pH 3.5) at flow rate of 2 ml min(-1), and most matrix materials were removed from the column to waste. After 0.5 min washing, the valve was switched to another position so that the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (acetonitrile-20 mM NaH2PO4 adjusted pH 3.5, 16:84, v/v) at flow rate of 1.5 ml min(-1), and then separated on the analytical column (Ultimate (TM) XB-C-18, 4.6 mm x 50 mm, 5 mu m). The complete cycle of the on-line SPE preconcentration purification and HPLC separation of the analytes was 5 min. Calibration curves with good linearities (r = 0.9994 for plasma sample and r = 0.9988 for urine sample) were obtained in the range 0.02-5 mu g ml(-1) in plasma and 0.05-10 mu g ml(-1) in urine for faropenem. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully utilized to quantify faropenem in human plasma and urine to support the clinical pharmacokinetic studies. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [21] Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization
    Emara, S
    Askal, H
    Masujima, T
    BIOMEDICAL CHROMATOGRAPHY, 1998, 12 (06) : 338 - 342
  • [22] Determination of celecoxib in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chow, HHS
    Anavy, N
    Salazar, D
    Frank, DH
    Alberts, DS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 167 - 174
  • [23] Determination of noscapine in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chollet, DF
    Ruols, C
    Arnera, V
    JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01): : 81 - 85
  • [24] High-performance liquid chromatography with solid-phase extraction for the quantitative determination of nilotinib in human plasma
    Miura, Masatomo
    Takahashi, Naoto
    Sawada, Ken-ichi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (07) : 789 - 793
  • [25] DETERMINATION OF AMOXICILLIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND SOLID-PHASE EXTRACTION
    KRAUWINKEL, WJJ
    VOLKERSKAMERMANS, NJ
    VANZIJTVELD, J
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (02): : 334 - 338
  • [26] Determination of atazanavir in human plasma using solid-phase extraction and high-performance liquid chromatography
    Cateau, E
    Tournier, N
    Dupuis, A
    Le Moal, G
    Venisse, N
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 791 - 795
  • [27] Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization
    Emara, Samy
    Askal, Hassan
    Masujima, Tsutomu
    Biomedical Chromatography, 12 (06): : 338 - 342
  • [28] Determination of epitestosterone in human urine by off-line immunoaffinity solid-phase extraction coupled with high performance liquid chromatography
    Xu, Li
    Qiu, Shuang
    Sun, Cui-Jin
    Deng, Qin-Pei
    Chen, Hong-Xu
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1443 - 1448
  • [29] DETERMINATION OF PENTOXIFYLLINE AND ITS METABOLITES IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH SOLID-PHASE EXTRACTION
    MANCINELLI, A
    PACE, S
    MARZO, A
    MARTELLI, EA
    PASSETTI, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01): : 101 - 107
  • [30] Determination of ginsenoside Rg3 in plasma by solid-phase extraction and high-performance liquid chromatography for pharmacokinetic study
    Wang, HL
    Zou, HF
    Kong, L
    Zhang, YK
    Pang, H
    Su, CY
    Liu, GY
    Hui, M
    Fu, L
    JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02): : 403 - 409